How to choose and install a check valve for ventilation

Maintaining a healthy and cozy living environment in your house requires proper ventilation. It assists in controlling temperature, eliminating surplus moisture, and preventing the accumulation of dangerous pollutants. A vital part of any ventilation system is the check valve, which regulates airflow in an important way. This guide will discuss the value of check valves for ventilation and offer helpful advice on selecting and installing the best one for your house.

Backflow preventers, sometimes referred to as check valves, are straightforward but efficient devices made to let airflow through one opening while blocking it from returning the other way. They aid in making sure that air flows smoothly and without interruptions through the ducts, exhaust vents, and other parts of a ventilation system. Poor indoor air quality or decreased energy efficiency could result from air unexpectedly escaping or entering the system in the event of a malfunctioning check valve.

A check valve for your ventilation system should take a number of factors into account. The most important factor is compatibility with your current ventilation and ducting system. Selecting a check valve that satisfies the requirements of your system is crucial because they are available in a variety of sizes and configurations. In addition, you should think about the valve’s material. Depending on your needs and price range, you can choose from plastic or metal.

An additional crucial factor to take into account when selecting a check valve is its airflow capacity. Your ventilation system’s air volume should be handled by the valve without resulting in any obstructions or bottlenecks. A valve that is too big could result in inefficiencies or excessive noise, while a valve that is too small could obstruct airflow. Make sure you get advice from an expert or check the manufacturer’s instructions to find the right size for your use.

The effectiveness of your ventilation system depends on how well you install the check valve you’ve chosen. To begin with, carefully examine your ductwork to determine where the valve should be placed. It should ideally be installed in a straight duct segment with enough space on either side to permit adequate airflow. If you have any questions about any part of the installation process, don’t hesitate to ask a qualified HVAC technician for assistance. Pay close attention to the manufacturer’s instructions.

What is the check valve for

The valve’s primary purpose is to only allow air to flow in one direction; if the opposite flow happens, it should be closed right away. It is very simply implemented: a barrier rotating on the transverse axis inside the channel overlaps the passing cross section. A second possibility is to use thin polymer petals to seal the passage.

Reference: The common characteristic shared by all check valves utilized in ventilation, water supply, and heating systems is their high aerodynamic (hydraulic) resistance to gas flow (water). Thus, the inference is that placing the air distribution components anywhere could result in a breach of the room ventilation plan.

Prior to discussing the range of applications for valves, it’s crucial to remember that the majority of home ventilation systems operate organically. A vertical pipe or mine’s traction draws in air and creates a vacuum; this compensates for any losses with new air coming in. When should one use a check valve?

  1. When connecting a kitchen hood to the output of the mine. To maintain natural air exchange with the fan disconnected, the ventilation center is connected to the tee with a return device.
  2. If the forced release is organized using a horizontal duct laid through the wall. After stopping the fan, the valve will not allow the room to get into the room from the outside.
  3. In systems of supply and exhaust ventilation with forced motivation-for the distribution of flows.
  4. Когда необходимо устранить ошибки проектировщиков либо монтажников вентсистем с наименьшими затратами.

High-rise building grate with ventlapan effectively blocks wind from blowing onto upper floors. In a different instance, the exhaust pipe’s end is either inadequately shielded from the wind or not elevated high enough above a rural home’s roof. However, the inflow is still required in order for the poor traction to open the valve sash.

Incorrect use of elements

Installing a ventilation grill with a check valve in the bathroom or kitchen is a common mistake. He is said to provide protection against odors coming from nearby apartments in a multi-story building. Why this strategy is flawed:

  • The reason for the penetration of unpleasant odors is to tip the thrust in the ventilation mine;
  • The craving is overturned due to the lack of an influx, a larger shaft (in the kitchen) forces a smaller channel (in the bathroom) to work in the opposite direction, the air moves from top to bottom;
  • If you install the compensating supply device in a window or wall, both pipes will begin to stretch the exhaust air, extraneous smells will disappear;
  • The ventilation grille with reverse petals will protect the apartment from the “alien” air by 90%, but the remaining 5-10% of the gases will leak – the sash does not fit hermetically;
  • the work of natural ventilation without an influx will not improve.

Note: Refer to a different source for information on properly creating natural air exchange in a rural home.

Allow us to present a second example, which can be found on numerous websites: a forced ventilation plan for the kitchen and bathroom. This involves two fans on a common duct; two check valves stop parasitic flows from happening; a third shuts off the outside air. Why the drawing’s scheme is inadequate

  1. According to the requirements of sanitary standards, an extract from the bathroom (bathroom, toilet) is prohibited to combine into one channel with kitchen ventilation.
  2. With the fans disconnected, the smells of the toilet leak into the kitchen.
  3. When starting two fans, it is at the same time difficult to predict the behavior of air flows. Both valves will open, but the unit from the bathroom will “give” the kitchen, since it is installed in the direct section.

To be clear. Stronger kitchen umbrella fans have the potential to "strangle" the bathroom unit and obstruct the toilet hood, at the very least.

In conclusion, you must have a separate duct for every room as required by standard practice. Next, check valves are added to horizontal pipe outputs to prevent cold air from entering the building. It is permissible to combine the boarding and restroom ventilation systems, as depicted in the drawing.

Types of return devices

The check valve types listed below are utilized in the ventilation systems:

  • air damper – gravitational and spring;
  • petal (membrane);
  • Double -barrel type "butterfly".

Plastic, aluminum alloy, galvanized steel, or stainless steel are used to make the components. Certain manufacturers, like Ventts, have merged models with a plastic sash and a metal body.

Industrial vent systems are the primary application for gapping shutters. They have the function of stopping the opposite flow or controlling the air volume, either through manual or electric drive as seen in the picture. Steel valve fittings are used outdoors, while plastic ones are utilized indoors.

Furthermore. Additionally, the check valves have ventilation grilles with shutters that turn horizontally. Similar in concept, rectangular sash shutters close in response to gravity, keeping outside air from entering the channel.

Let’s discuss the video for a little bit. The master’s words don’t always match reality, but he gets one thing right: he installs an outer grille with gravitational sashes.

Design and principle of operation of the damper

The components of a single-barreled check valve are as follows:

  • Corps of round or rectangular shape;
  • From the inside, a damper is attached to the walls, which rotates freely on the transverse axis;
  • In a closed position, the sash is held by the spring (there is no gravity models in gravity).

The spring-loaded damper’s normal position is closed when its rotational axis aligns with the pipeline’s longitudinal axis. The fan opens the sash with air flow pressure after it is turned on, and it automatically closes when it is disconnected. A distinctive sound is produced upon closure, which is why the second valve is called "Clap."

The double-barrel "butterfly" is set up in the same way, but there are two dampers instead of one, and a spring is positioned in the center. Only forced ventilation systems allow for the operation of either type of ventilation. It takes more force than natural traction to open a sash that is spring-loaded.

The damper’s rotational axis in single-barrel gravitational valves is eccentrically positioned, that is, moved above the duct’s axis. Because of this, the large wing outweighs the smaller wing, which is why there are no springs used to close it. Here, the proper installation of the check valve is crucial.

  • If you insert the element into the horizontal pipe according to the instructions (the axis of rotation is above the center of the air duct), the damper will immediately close;
  • If you turn the ventilatan upside down, the passage will remain open;
  • When installing on a vertical channel, closing the sash also depends on the position of the element.

There are two ways to write "CLAP" for natural ventilation: vertically but on an upward stream, or horizontally in a closed state. In other provisions, it is hard to forecast how the sash will behave; if the reverse air flow happens, the valve might not function.

"Crackers" for the home can be found in other ventilation accessories, such as wall flanges and connecting nipples. Additionally, there are "butterfly" exhaust fans that have a check valve.

Membrane valves and gravity lattices

The primary shutter in products of the first kind serves as an internal ventilation grate slot or a thin polymer film membrane next to the body. The edges of the film are left free and are affixed to the valve’s central axis.

The film’s extreme petals are bending and passing air due to the force of natural traction or fan pressure. The lavsan membrane locks the passageway once more next to the frame when the gases move in the opposite direction. Grilles and exhaust fans can both use lepeline-type valves.

Note: This type of air valve is simple to operate with your hands. To join two film petals to the standard lattice, simply press them in place using a cardboard gasket that has been cut out. You can see an example of production instructions below the video.

Multicked gratings operate using the damper principle, allowing them to collapse under their own weight. Utilization area: exhaust ducting channels that are pulled out through the walls. There is no natural craving in horizontal pipes.

Choice recommendations

Depending on the installation site and ventilation plan, the return element is chosen:

  1. To connect the kitchen hood, use the “cracker” of the gravitational action corresponding to the shape of the duct. The task of this valve is to preserve natural air exchange during the inaction of the fan.
  2. A grille with a membrane valve (home -made or factory) is placed in the opening of an exhaust mine if the craving is overturned by gusts of wind. It is better to get rid of the smells with another method – to install wall supply valves to resume normal air exchange.
  3. In private houses, a local extract of a local hood is often laid directly through the outer wall. So that the cold air does not blow off the wind inside the ventilation, install a multi -wound exhaust grille on the outside.

In forced air supply mechanical ventilation systems, valves are utilized in accordance with the design specifications and scheme created by the designer. We do not recommend creating such an air exchange on your own because mistakes cannot be avoided and the cost of corrections will be prohibitive.

Suggestions. Purchase low-cost plastic items to install inside the rooms. Glottering is unsightly; drywall will need to be sewn for pipes and other ventilation components.

How the check valve is installed

Installing a membrane outlet and a multi-wound lattice is easy and doesn’t require a comprehensive guide. As directed by the manufacturer, the elements are mounted on the wall and linked to the air ducts.

One more thing: it’s preferable to insulate the wall canal when adding an external lattice. The pair will start to condense as soon as the outgoing air makes direct contact with the cold walls. The water will freeze and turn into ice after the fan is turned off.

Take into account the following details if you choose to install a gravitational check valve for hoods:

  1. Pass the element at the exit from the tee, but in an inverted position, as taken in the photo. With a non -working fan, the damper will open.
  2. It is better to place the tee on the vertical section of the air duct, and not under the very ceiling. Then you can build a decorative box and completely hide the pipe.
  3. On the sides of the decorative box, provide ventilation grilles, as the home master offers on the video.
  4. Do not put the "chuckle" and the tee is close to the entrance to the mine. In this place, the stream turns, auging is formed, the damper may not be closed to the end.
  5. Do not have a damper vertically or at an angle, as many craftsmen like to do. In this position, the sash is loosely closed or does not want to open.

Suggestions. Make sure the circuit is operating properly before installing a check valve on silicone sealant. Put the "cracker" into the tee, switch the performance by turning the hood on and off five to ten times. Make sure the damper is fully open and slammed.

Considerations when choosing a check valve Installation steps for a check valve
1. Type of valve: Choose between spring-loaded and gravity-operated valves based on your needs. 1. Identify the direction of airflow: Determine the airflow direction in your ventilation system.
2. Size compatibility: Ensure the valve fits the diameter of your ventilation duct. 2. Positioning: Install the valve in the correct orientation to allow airflow in one direction only.
3. Material: Select a valve made from durable materials suitable for your environment. 3. Secure installation: Use appropriate fasteners to securely attach the valve to the duct.
4. Maintenance requirements: Consider ease of access for cleaning or maintenance. 4. Test functionality: Ensure the valve opens and closes smoothly before completing installation.

An essential step in guaranteeing the efficacy and efficiency of the insulation and heating system in your house is selecting and installing a check valve for ventilation. These valves are essential for controlling airflow, stopping backdrafts, and preserving the quality of the air inside buildings. When selecting a check valve, consider factors such as the size and type of your ventilation system, the airflow requirements, and the specific needs of your home.

The type of material that a check valve is made of is one of the most important factors to take into account. Check valves are frequently found in galvanized steel, plastic, and aluminum. Every material has a unique set of benefits and things to keep in mind. Plastic valves are perfect for the majority of residential applications because they are lightweight and resistant to corrosion. Galvanized steel valves work well in hot conditions, but aluminum valves are robust and long-lasting.

The type of check valve mechanism is another crucial consideration. There are several varieties available, such as gravity-operated, spring-loaded, and flap-style valves. Gravity-operated valves have a more straightforward design and are better suited for vertical installations, whereas spring-loaded valves are frequently used in situations where a tight seal is necessary. Backdrafts can be avoided and different airflow conditions can be accommodated by flap-style valves.

The check valve must be installed correctly to guarantee both its longevity and functionality. As directed by the manufacturer, the valve should be installed in the ventilation duct in the proper orientation. It’s crucial to place the valve so that it can control airflow and stop backdrafts without creating any obstacles. To guarantee peak performance and quickly resolve any possible problems, the valve also needs to undergo routine maintenance and inspection.

In summary, maintaining indoor air quality, increasing energy efficiency, and guaranteeing the overall efficacy of your heating and insulation setup all depend on the proper check valve installation and selection for your home’s ventilation system. You can select a check valve that best suits your needs and enhances the efficiency of your home’s ventilation system by taking into account elements like materials, valve mechanism, and appropriate installation methods.

Choosing and installing a check valve for ventilation is crucial for maintaining optimal airflow and energy efficiency in your home. A check valve helps prevent backflow of air, ensuring that fresh air comes in and stale air goes out smoothly. When selecting a check valve, consider factors like compatibility with your ventilation system, size, and material durability. Installation should be done carefully, ensuring proper placement and secure attachment to prevent leaks. Regular maintenance, including cleaning and inspection, will ensure the check valve continues to function effectively. By making informed choices and installing a check valve correctly, you can improve indoor air quality and enhance the overall efficiency of your home"s ventilation system.

Video on the topic

Extractor fan in the kitchen. Check valve and natural ventilation

Check valve check valve / check valve installation

Flight valves, types of check valves/fans with a check valve/vents, householder/ventilation

Hood and ventilation, check valve

What type of heating you would like to have in your home?
Share to friends