How a two -pipe heating system works

Maintaining a cozy and energy-efficient home requires an understanding of how your heating system operates. The two-pipe heating system is one popular kind of heating system that is present in many homes. We’ll examine in more detail how a two-pipe heating system works and effectively distributes heat throughout your house in this article.

A two-pipe heating system is a type of hydronic heating system that uses hot water to distribute heat throughout a building. Unlike a one-pipe system, which uses a single pipe to supply hot water to radiators and return cooler water to the boiler, a two-pipe system uses separate pipes for the supply and return lines. This design allows for more precise control over the flow of hot water and provides more consistent heating throughout the building.

A two-pipe heating system’s boiler, which raises water’s temperature to a set point, is its central component. The water is pumped via the supply pipe to the radiators and other heat emitters located throughout the building once it reaches the appropriate temperature. Warming the rooms, the hot water’s movement through the radiators releases heat into the surrounding area.

Once the water has passed through the radiators, it returns to the boiler through the return pipe, where it is reheated and recirculated through the system. This continuous cycle ensures that the building remains consistently warm and comfortable, even on the coldest days.

Apart from its reliable heat output, a two-pipe heating system presents numerous additional benefits. Individual rooms or zones within the building can have their temperature controlled because each radiator has its own supply and return pipes. You can now change the temperature in different parts of your house to suit your own needs, giving you more flexibility and energy savings.

Component Function
Boiler Heats water to a set temperature.
Pipes Carry hot water from the boiler to radiators.
Radiators Transfer heat from hot water to the room.
Thermostat Controls boiler to maintain desired temperature.
Return Pipes Carry cooled water back to the boiler.

General information about the two -pipe heating system

Radiators and a boiler are connected by one or more closed circuits in any heating system that uses liquid coolant.

The term "two-pipe wiring" refers to the supply of hot coolant along one branch of the circuit and its return to the other.

  1. The organization of the movement of the coolant is a duplicate and forced.
  2. The design is open or closed, horizontal or vertical.
  3. Pipe wiring – radiation, dead end, ring.

You can attain optimal compliance with operating conditions by combining properties.

Advantages and disadvantages

The operational qualities and technical features should be taken into account when weighing the benefits and drawbacks of the two-pipe system.

Advantages Flaws
The same temperature of the coolant in all radiators Increased pipes consumption – 2 branches must be carried out to the radiator, which leads and removes
Adjustment of the heat transfer of each battery Large diameter of the riser and eyeliner to the first radiators in the circuit
Small hydraulic resistance
The performance of the entire system during a breakdown of one or more radiators
Use in buildings of large number of storeys
The flexibility of the eyeliner options – in the floor, in the walls, along the walls, under the ceiling and behind the false spot

The disadvantages listed in the table are shared by the two pipe networks. All wiring options, though, may have inherent drawbacks that restrict their usefulness; this is something we will continue to take into account.

Describe the schemes and how a single-pipe heating system operates.

Open and closed two -pipe heating systems

There are three methods for circulating the coolant:

  • self -binding (gravitational);
  • compulsory using a pump;
  • combined.

Furthermore, the systems are separated into closed and open categories. This indicator describes how the atmosphere and coolant interact.

All liquid coolants expand in volume when heated. Since it is well known that the liquid is not really lend to compression, an expansion tank—a separate device—is needed to hold the "surplus."

Open type

In open systems, the pipe connects the tank to the atmosphere and it is positioned at the highest point.

The open system has the advantages of simplicity and requiring few extra devices. An expansion tank can be made of any metal capacity.

The tank is filled with water as needed. For this:

  • Install the taps and connect the system with the water supply;
  • add the coolant through the opening hatch.

Take note! Antifreeze cannot be added to an open system since the evaporated gases can be toxic.

Closed type

A sealed expansion tank containing a balloon membrane or elastic diaphragmen is used in closed systems. The device is divided into two parts by the membrane. One chamber receives a pressure boost of 1.2–1.5 atm while the other is linked to the pipe of the heating system.

The excess coolant fills the tank as it heats up and expands. The membrane forces coolant into the system as the fluid’s temperature drops. You can keep up the pressure required for the boiler by pre-injecting air into the air tank. The boiler’s automation shuts off the power when the pressure drops below 1.2 atm.

Glycols or antifreezes can be used in sealed constructions.

Closed networks make control over the overall structure’s performance easier because the tank is situated close to the boiler.

Self -stroke schemes

The principles of gravity and self-stroke systems operate because of these laws. At 50 °C and normal atmospheric pressure, the density of the water is 988 kg/m^3 and 968 kg/m^3 respectively.

The coolant that has cooled in the radiators travels downward and returns to the boiler in accordance with the "return" as hot water (lighter) rises through the pipes in the heating circuit. There is no use for the circulation pump.

Benefits of self-storage facilities:

  • Rare cases of feloning – the low speed of the coolant slowly squeezes the air into the expansion tank;
  • a long service life due to the lack of a circulation pump and a membrane expansion tank that have a limited resource;
  • the use of cheap coolant (water) – with leaks you will not have to buy antifreeze;
  • Self -regulation – with a decrease in air temperature in the building, the water in the system is cooled faster, which increases the speed of circulation, increasing the temperature in the rooms.

Being self-sufficient in terms of electricity enables us to install solid fuel boilers, which won’t boil or blow up when the circulation pump is turned off, and operate the system in summer houses where the power is frequently turned off.

Self-stroke systems have several drawbacks.

  • a low pressure drop forces the use of large diameters (up to 75-100 mm) in risers and up to 50 mm in the presenting branches;
  • The maximum circuit length is 30 m;
  • long warming after turning on, caused by the slow movement of the coolant;
  • pipelines are laid at an angle to the horizon, and the expansion tank cannot be taken outside the heated room, which affects the attractiveness of the interior;
  • Not suitable for buildings above 3 floors.

Self-storage systems are therefore the best option:

  • in the area with interruptions in electric supply;
  • for rooms where the appearance of the structure is not important;
  • for country houses no higher than 7-9 meters;
  • for solid fuel boilers (coal, firewood, briquettes), which cannot be stopped instantly when turning off the electricity.

Installing a bypass with a pump into a supply pipe gap eliminates some drawbacks. When the power is turned off, the coolant is directed through an open pipe by the very and pumped into the system using a circulating pump in normal mode.

Forced circulation schemes

A pump must be installed in forced circulation systems; it can be removed or installed as part of a boiler. Installation is done in a return pipe, where the coolant is at room temperature, prior to a boiler.

The scheme benefits from the pump in this way:

  • The heating of the radiators occurs quickly, since the speed of the coolant increases;
  • Powerful pumps allow you to create large contours in length;
  • All radiators have approximately the same temperature;
  • In closed systems, it is permissible to use antifreeze, which will not freeze and will not tear the system with prolonged shutdowns;
  • pipelines do not require slopes;
  • Pipes of smaller diameter are used, which reduces expenses.

Drawbacks:

  • frequent cases of felining due to the rapid speed of moving the coolant;
  • energy dependence – you will need to install powerful autonomous power supplies;
  • High price of powerful and intracella pumps.

Take note! In systems that use solid fuel boilers, a continuous nutrition source must be supplied. The boiler cannot be stopped quickly, and without circulation, the coolant boils and overheats, causing the heat exchanger to explode.

  • large in the area of the building with long heating contours;
  • locality with high -quality power supply or house with reservation of electricity.

Forced circulation is used in the majority of contemporary double-circuit systems.

A two-pipe heating system heats your house with hot water that travels from the boiler through one pipe and returns to the boiler through another pipe to be reheated. Your home will always be consistently warm thanks to this ongoing loop. While the return pipe returns the cooled water to the boiler for further heating, the hot water radiates heat into the rooms to create a comfortable atmosphere. This system works well and effectively to keep your house warm in the winter.

Types of pipes wiring and building heating systems

The locations of pipelines and radiators define the types of heating systems.

Differentiate between layouts within layouts:

  • horizontal or vertical;
  • upper or lower wiring;
  • with a direct and reverse flow of the coolant;
  • pipe turning to radiators – dead end, radiation, ring.

Depending on the operating conditions, the choice is determined by the qualitative characteristics of each type and their combinations.

Upper or lower wiring

Systems with forced circulation, gravitational circulation, or both types of circulation combined can be equipped with upper wiring. The upper horizontal pipe, which distributes the hot coolant along the risers, receives supply from the central riser. The upper floor ceiling has pipes underneath it.

Advantages Flaws
The difference in pressure allows the use of a large number of radiators Part of the heat of the pipe is given in the upper part of the room, which reduces the effectiveness
Suitable for various construction schemes Large diameter wiring is required, which is more expensive
Low hydraulic resistance The appearance is not suitable for part of the interiors
The ability to install thermostat on each radiator or riser The expansion tank will sometimes have to be taken out for an unheated attic and carry out high -quality insulation
Low pressure on the network (up to 3-4 atm) is suitable for any type of radiators, including aluminum For the installation of the warm floor, additional equipment will be required

Powerful pumps are purchased to pump the coolant, whose volume is increased by the diameter of the pipes and the length of the contours.

The supply pipe and return are located below the level of the radiators in lower wiring systems.

These kinds of schemes are mostly employed in mandatory circulation systems.

Benefits of the lower wiring include:

  • pipelines can be hidden in the floor or walls;
  • It is not required to make a common riser, which allows you to organize heating of the first built floor, and the second and subsequent equip in as necessary;
  • By installing the collectors, you can organize the "warm floor" system.

Users list frequent imports and installers’ issues with initial setup and balancing as some of the drawbacks.

Vertical and horizontal wiring

Horizontal and vertical scheme differ in the presence of the main riser.

Multi-story buildings are the primary application for vertical types. The horizontal species works well with structures of any height as long as the structure is taken into consideration and the pump is chosen for the necessary power.

In heating systems, there are various basic patterns of pipe wiring that designers and installers can identify.

Fatal circuit The majority of suburban homes are equipped with country homes, where the coolant moves in the opposite direction, towards the house. The supply and outlet pipes are connected to each radiator. The pump is in charge of the circulation. The system’s primary benefit is that all radiator coolant reaches the same temperature, and regulators enable you to keep each room’s microclimate at the ideal level.

  • a large number of welded and coupl compounds;
  • A professional hydraulic calculation is required if there are more than 3 radiators in one circuit;
  • often noise from moving coolant occurs.

You can conceal the pipes beneath the flooring or in the screed by using the Tichelman loop or the scheme with the coolant passing movement in the lower horizontal wiring. Installers report that the passing scheme needs little adjustment. The Tichelman loop requires larger pipe diameters, but it functions flawlessly with a large number of radiators.

Radiation wiring is installed using collectors that are placed on every floor of the structure.

You can install the "warm floor" system and each radiator is nourished independently thanks to this scheme. One significant disadvantage is the high expense of purchasing pipes.

What type of wiring to choose

The purported operating conditions determine the construction scheme to be used:

  1. In buildings above 2 floors, heating with the main risers according to a vertical scheme is mounted.
  2. In areas with frequent or long -term shutdown of electricity, gravitational systems with energy -dependent boilers are preferred.
  3. For large in area of objects, systems with forced circulation are equipped, built on horizontal type of wiring. The most suitable scheme B is the loop of the tichelman.
  4. For independent performance, inexperienced users choose a dead end wiring with several shoulders.
  5. When pouring pipes on the floor, it is advisable to dwell on the radiation scheme with the collectors on each floor – with an emergency rupture of the pipe, you can turn off 1 radiator, delaying the cost of opening the floors.
  6. Small cottage houses, baths and utility rooms are equipped with a dead end scheme.

A case-by-case analysis is necessary, taking into account the benefits and drawbacks of various heating system types.

Hydraulic calculation of a two -pipe heating system

The goal of the hydraulic calculation is to choose a circulation pump with enough power if needed and to ascertain the minimum pipe diameter required at the design stage.

The following steps make up the entire sequence:

  1. Calculation of the required capacity of radiators and building a common circuit of thermal balance.
  2. Determination of the flow rate of the coolant in each shoulder of the circuit.
  3. Calculation of the diameter of pipelines.
  4. Selection of the necessary product performance.

We suggest that you get in touch with a specialized organization so that precise calculations can only be made by experts with training in heat engineering.

The majority of masters who wish to equip their small house independently with a heating system can only estimate 10-15% of the reserve based on factors like boiler power, pump performance, pipe diameter, and battery power.

Determination of the minimum required power

You can use the calculator to determine the precise thermal power of the radiators and, by extension, the boiler.

Standard construction materials and high-quality insulation mean that, in the north, 1.5–2 kW of thermal capacity radiators are needed for every 10 m^, in the middle lane, 1-1.5 kW, and in the south, 0.6–1 kW.

After calculating for every room, all of the indicators are placed. One scheme receives data application for additional computations.

The flow rate of the coolant

For every shoulder in the circuit, the amount of coolant required per unit of time is computed.

Use the formula G = 860*Q/Δt to accomplish this.

  • G – the flow rate of the coolant kg/h;
  • Q – thermal power of radiators in the calculated area (kW);
  • Δt – the difference in the temperature of the coolant at the input and output of the radiator, usually 20 about.

For instance, a branch with 3 kW of radiators overall and water as coolant will require 860 * 3/20 = 129 kg of consumption per hour.

The outcome is moved to water data at 60 °C (the most common parameter in individual homes) for additional computations.

Apply the following formula: GV = G /3600ρ.

  • GV – water consumption measured in l/s;
  • ρ – water density at 60 ° C.

129/3600*0.983 = 0.035 l/s is the result.

The value that results from the hydraulic calculation of the pipes must then be located in the tables; these tables are available on the websites of the manufacturers of the pipes.

There will be sufficient pipe with an internal diameter of at least 16 mm for our example.

Crucial! Polypropylene – internal and external diameters of steel pipes are marked.

Every circuit undergoes independent computations, which are then shown on the diagram. When the consumption in the areas is folded, a general indicator is obtained and considered when selecting the circulation pump and pipe risers.

During the winter, a two-pipe heating system is a dependable and effective way to heat your house. This system guarantees a uniform and even distribution of heat throughout your house by utilizing two distinct pipes, one for the inflow of hot water and the other for the outflow of cooler water back to the boiler.

A two-pipe system’s capacity to keep various rooms of your house at a constant temperature is one of its many noteworthy benefits. More accurate temperature control is possible because each radiator has its own supply and return pipes, which allow you to regulate the heat output separately.

The two-pipe system is also reasonably simple to install and maintain. You can make sure that your heating system runs effectively, keeping your house comfortable and saving money on energy bills, with the right insulation and routine maintenance.

In summary, a two-pipe heating system provides a practical way to maintain a warm and cozy home. It is a fantastic option for homeowners wishing to upgrade the insulation and heating in their homes because of its effective design and capacity to deliver steady heat.

What type of heating you would like to have in your home?