The gas column is not ignited – the restoration of the wick of the household gas semi -automatic water heater

After a long day, picture yourself arriving home and anticipating a warm shower to unwind, only to discover that your gas water heater won’t ignite. Many homeowners have experienced this annoying circumstance. Thankfully, the wick of the domestic gas semi-automatic water heater is usually the problem. You can avoid wasting time, money, or aggravating yourself while waiting for a repair technician by learning how to restore the wick.

Gas water heaters are standard equipment in a lot of houses, offering dependable and effective hot water when needed. But just like any appliance, they occasionally may have issues. One of the most frequent problems is not lighting, which is frequently brought on by a broken wick. The wick, which ignites the flame that heats the water, is an essential part of the heater’s ignition system.

A lack of hot water may result from the wick becoming clogged or damaged, which can hinder the gas from igniting correctly. Thankfully, replacing the wick only requires a few simple tools and some basic knowledge, and it’s a fairly easy task. With a little knowledge of how the wick functions and a few easy steps, you can quickly restart your gas water heater.

We’ll show you how to fix the wick on your domestic gas semi-automatic water heater in this guide. We’ll go over every step of the process, from figuring out what’s wrong to solving it to getting the wick working again. This guide is intended to assist you in quickly getting your gas water heater operating again, regardless of your level of experience with do-it-yourself projects or desire to simply save costs and effort.

Problem: Gas column not igniting
Solution: Restore the wick of the household gas semi-automatic water heater
Contents
  1. Reasons for the lack of flame on the wick of a gas column
  2. Search for a malfunction due to which the gas column does not ignite
  3. Blocks in the system
  4. What to do if the column does not turn on
  5. How a gas column works
  6. Problems of external nature
  7. A diaphragm of the gas unit
  8. Does the pressure of water affect the performance of the column
  9. Neva gas column does not ignite the reasons
  10. Water circuit
  11. Gas contour
  12. Ignition system
  13. Safety system
  14. Why the gas column does not light up
  15. Typical breakdowns
  16. If the gas column does not light up
  17. Когда Вектор зажигается с запозданием
  18. Lack of traction in the chimney
  19. Prevention
  20. The gas column does not ignite
  21. Reason 1. There is not enough traction
  22. Reason 2. The supply elements were discharged
  23. Reason 3. Weak pressure of water
  24. Reason 4. There is no gas supply
  25. Other problems when using a gas column
  26. Automatic gas column does not light up
  27. Causes
  28. External factors
  29. Internal breakdowns
  30. Water supply problems
  31. Internal breakdowns
  32. Ignition system does not work
  33. The water heater is incorrectly configured
  34. The water knot membrane failed
  35. The heat exchanger clogged
  36. Soot accumulated on the heat exchanger
  37. The main or smell burner clogged with mud
  38. What to do if gas does not enter the gas column
  39. Possible reasons why the column does not ignite
  40. Why the gas column does not light up
  41. Typical situations and causes
  42. Video on the topic
  43. The gas column does not light up.
  44. The gas column does not ignite- we eliminate in 5 minutes.
  45. Bosch gas column does not ignite. The wick goes out…
  46. The gas column rises or does not light up

Reasons for the lack of flame on the wick of a gas column

  1. The air supply hole into the wick is clogged. Air is carried out through this hole to ensure the combustion of natural gas on the tip of the fabric.
  2. The coil of the electromagnetic valve burned. The electric magnet holds the valve rod, after its breakdown, the valve will be closed.
  3. The thermocouple. The thermocouple, while in flames, produces the voltage supplied to the electromagnet.
  4. The sensors of monitoring the temperature of the water and the state of the chimney (the presence of traction) are faulty. With a value of up to + 82 0C, the sensor is in a closed position, from above this temperature, its bimetallic plates diverge and the chain opens. Violate normal contact between the two plates can oxidize the surface, mechanical or thermal damage.
  5. The electrical circuit of the flame control system is impaired. All the elements of the flame control system are interconnected by wires. Their malfunction will inevitably lead to a violation of the entire system.
  6. A nozzle or a gas supply tube into a wick is clogged. The internal diameter of the tube is 2.5 mm (external 4 mm) diameter of the outlet of the nozzle 0.1 mm. These elements can clog with soot, dust, etc. D.
  7. The work of Piezoelent, from the sparks of which the gas ignition is broken, is disturbed.

Search for a malfunction due to which the gas column does not ignite

A gas column that is turbocharged and has electric ignition is present. The column clicks when the hot water is opened, but it does not light up. The fan turns on when it hears an electric discharge.

You must perform an inspection first, and in order to do so, we remove the column cover. Four bolts hold it in place: two from below and two from above. The handles for the temperature, winter-summer mode, and flame regulator are also removed. Upon inspection, everything appears to be in working order; no wires have burned out, and there is no water flow.

The way it works is this: a gas valve opens in response to the appearance of water flow, creating an electric discharge and lighting the gas. At the same time, the fan is turned on to extend the combustion products out into the street. The column shuts off if there is not enough water pressure, the hood is broken, or the gas is rotten.

Now let’s open the crane and observe what transpires. The fan turned on, the electrodes discharged, water rustled through the heat exchanger tubes, but the gas did not light up. Verify the functionality of the relay, or microswitch, which opens the gas supply valve when there is enough water pressure. This requires turning on the tap once more, which moves the relay tongue.

It functions, indicating that there is enough pressure to keep the gas column operating. Check the gas valve’s functionality now. Without opening the water, we use a screwdriver to move the same tongue in order to accomplish this. The gas valve operates if there is a spark on the electrodes and the fan has gained momentum.

The smell electrode did not spark, and the problem was discovered quite quickly. Extreme is one of two of them. The control in the middle shuts off the gas supply when there is no flame.

Blocks in the system

The previous post explained how to clean the mesh filter. Additionally, the heat exchanger system needs to be cleaned because scale builds up there while it is in use. To do this, take out the heat exchanger and submerge it in citric acid-infused water. It is necessary to preheat the solution-containing container on the stove. These solutions should also be rinsed inside the heat exchanger.

Burners in "Junkers" and other comparable gas devices frequently become clogged. The reason the column won’t ignite is because of a big cluster of soot. It is worthwhile to clean the burner during the heat exchanger cleaning process. The exterior of the device is cleaned with a citric acid solution. Cleaning the burner’s interior on the street is preferable.

This post will explain how to diagnose and fix a household gas semi-automatic water heater’s wick that won’t light. For many homes, a gas water heater is a necessary appliance because it provides hot water for a variety of everyday tasks. It can be annoying and inconvenient when the gas column does not light. If you know how to fix the wick, though, you can avoid paying for professional repairs and save time and money. These easy steps and safety measures will help you restart your gas water heater quickly and guarantee a continuous supply of hot water for your home’s requirements.

What to do if the column does not turn on

Low pressure in the water supply system or the pressure in the pipeline should be systematically determined if this phenomenon is the reason for the work column’s refusal.

If the system experiences frequent pressure drops, you can install a pump in the apartment to raise the water pressure or swap out the column for one that is better suited to the water supply’s operational parameters.

Gas speaker models that have a water pressure control lever are also available. If the tap pressure is adequate but not high enough to allow the column to operate normally, then this kind of model will be helpful. It will be feasible to "adjust" the column under the current pressure with the use of a lever. The apartment owner’s financial situation will determine which option to select.

Should the water intake unit (mesh filter, rubber membrane) malfunction and prevent the column from turning on, these components need to be replaced or cleaned.

After using the equipment for two to three years, the membrane frequently becomes deformed. Replace the part if it has mechanical damage (such as breaks) and is elongated in a single direction. By taking off the water supply unit’s lid, you can examine the membrane’s condition. Silicone has a longer service life than rubber, so switching to it is preferable.

In order to determine the level of clogging in the filter, you need:

  1. Extract a water intake node from the equipment housing;
  2. Disassemble the block by unscrewing the nut;
  3. To inspect the filter cells for pollution.

Strong water pressure can be used to clean the filter. The equipment’s gas and water supplies should be cut off before beginning any repairs.

How a gas column works

Firstly, it is important to learn about the arrangement of the gas column before becoming acquainted with the fundamentals of diagnosing malfunctions, as this will have a significant impact on the repair. We will confine ourselves to familiarizing ourselves with general principles, rather than delving deeply into the intricate workings of numerous column models.

By historical standards, centralized hot water supply is a relatively recent development. There are several ways to solve the problem of heating water at home, but the titanium storage solid fuel heater was the most widely used solution. With coal, summed up as a titan; less frequently with firewood or fuel oil. The boiler’s water needed to be preheated. I had to spend at least an hour in order to adopt the bath. Of course, it was very inconvenient to use such a device. The issue of quickly heating water in gas columns was resolved.

The gas water heater’s apparatus

It involves using gas from the city line to heat tap water. A heat exchanger, which is situated directly above the gas burner and distributes the water flow through a network of thin tubes, speeds up the heating process. That way, hot water can be heated sufficiently quickly while in use, negating the need to build up hot water in the tank beforehand.

This is the main component of the gas column; the remaining filling controls the water’s temperature, ignites the gas, and ensures safety.

The primary burner’s butt occurs:

  • From the faint. A constantly burning smell, in turn, is turned on with a piezor -zero (automatic or manual from the button) or is manually ignited from the match. Unless, of course, you are lucky to get such a rarity into the property.
  • Piezorozzhig without a frying carrier.
  • Electronic ignition. In its device, an electronic ignition is similar to the ignition of a car

Systems of safety are:

  • Mechanical. Almost any column, even stuffed with electronics, is equipped with a simple device – a mechanical connection between the membrane in the water supply device and the valve in the gas pipe. The gas valve opens only if the pressure of water with sufficient force presses on the membrane. The principle is simple: no water – gas is not supplied to the burner, turn on the water – the burner turns on.

Problems of external nature

In the event that your column has stopped functioning, you must address external factors first. Their top concern is improper pipe placement, which is why even the stench frequently does not catch fire.

In the event that there were no prior issues, you should think about the following options:

  1. Problems with traction. The easiest way to check it is to substitute a burning match under the chimney. If there is a traction, the fire will reach for ventilation. If not, it"s time to clean it.
  2. Antenna near ventilation. Some negligent neighbors install antennas in such a way that they partially overlap the chimney. In this case, get ready for long quarrels demanding to remove the device. Such installation of antennas is strictly prohibited.
  3. Protective relay. It is necessary to turn off the column in case of overheating. Therefore, if the burner first ignites, and then goes out, you need to consider the probability of this problem. It is especially often manifested in the summer. The only way to solve is to replace the relay.
  4. Critically low battery charge or battery. This problem is characteristic of the speaker speakers. Solution – charging or replacing a power source.

Weak pressure is another major issue. This is particularly typical in older homes with inadequate water supplies.

In order to restore pressure to normal in your home, you will need to buy a specialized pump. If only one tap exhibits low pressure while the other tap functions normally, check the mixer for issues and see if there is a blockage in the pipeline.

A diaphragm of the gas unit

It is not possible to include a gas column if there is a rush of membranes. From robust and elastic rubber: it directs the gas supply to the product based on the water pressure.

Repairs are fraught with challenges: locating a replacement aperture, composed of resilient rubber, is particularly difficult in the retail sector, and dealers charge exorbitant fees.

Counseling! A silicone product can be used to replace the ripped membrane because it is a more dependable and long-lasting detail.

You should inspect the entire gas block of a working column in addition to the diaphragm because there are numerous components that can break. On the Internet, there are a ton of instructions for disassembling and then repairing.

Does the pressure of water affect the performance of the column

The equipment isn’t lit because there isn’t enough water pressure in the water supply. Check that it’s easy; all you have to do is turn on the cold water tap next to the sink. This is the exact cause if you notice that the pressure is low. However, if the pressure is very good, the gas device’s water node itself is the source of the malfunction. Most likely, a special membrane was distorted or the filters are clogged. A hot water supply crane that is covered from the inside can become clogged occasionally.

Work scheme for gas columns.

Very rarely, a deep cleaning filter that is added can be the source of low pressure. How can the malfunction be eliminated? Should you notice extremely low cold water pressure in the main water supply system, you should contact utility services to find out why. If the obstruction is preventing the column from igniting, the filters need to be taken out and thoroughly rinsed using specialized techniques.

Filters that are heavily contaminated need to be replaced because cleaning them is already pointless. If your hot water pipes become clogged, you should contact a professional to unclog them; do not attempt to do this task on your own. It is not advisable to attempt to straighten a deformed membrane; instead, a new one must be purchased and installed. The column should be turned off, the casing should be removed, and the nodes should be cleaned of any soot residue when it becomes clogged with combustion products and soot.

Because the hot or cold water supply is not adjusted, the column either instantly goes out or refuses to ignite when turned on. Simultaneously, one should avoid attempting to dilute hot water by increasing the flow of cold water, as this will cause the flame to gradually weaken and eventually shut off the column. This kind of incorrect action shortens the device’s service life. During installation, all of the taps must be adjusted correctly; if you are unable to do so, it is best to call a master.

Neva gas column does not ignite the reasons

Why is there no light in the Neva gas column? This can occur with any water heater, even the priciest ones, not just those from the well-known domestic brand. You must have a clear mental image of the gas column’s mechanism and operating principle in order to comprehend the cause of the issue. The list of components that are included is below.

Water circuit

A heat exchanger, which is a comparatively thin spiral-curved tube that heats water, makes up the majority of this shape.

Another crucial component of contemporary automatically-operating columns in the water circuit is an elastic membrane that is linked to a gas valve via a metal thrust.

The circuit’s water pressure is at its highest when the hot water crane is closed. The gas valve is kept closed and the membrane is bent as a result. A vacuum forms in the deputy space when the crane is opened and the water in the pipe starts to move. The membrane then bends inside the pipe to release the gas supply.

You should be aware that the water circuit’s input and output pipes are not interchangeable, so you cannot mix them up. As is customary to identify the taps for cold and hot water on the mixers, the input is typically marked in blue and the output in red.

Gas contour

The burner, which is situated beneath the heat exchanger, is the primary component of this contour.

Certain models have an additional burner called the smell, which is meant to burn continuously while using the column and is attached to the main burner rod.

In front of the primary burner is a gas valve that is managed by the security system’s multiple sensors and actuators in addition to the membrane.

Ignition system

We have already mentioned one of the options, which is a smell burner. The more recent type uses an electronic ignition that creates a spark to ignite the main burner. It is produced in one of two methods:

  • using batteries;
  • With the help of piezoelectric element.

The latter is powered by a water circuit-installed turbine.

The ignition system spare part

Safety system

Every component that makes up its structure is linked to a gas valve, and in the event of a freelance situation, it will instantly shut it off. There are some mechanical ones as well, but almost all of them (traction sensors, overheating, and flame) are electronic.

Therefore, a bimetallic plate or other heat-sensitive element that only opens the gas supply to the column when well-warmed is installed next to the smell burner, if there is one.

After a lengthy period of inactivity, filling the water heater is required for 20 seconds. ensure the gas supply by physically pressing a designated button. The safety element warms up sufficiently during this period, at which point the button can be released.

The electromagnetic valve is installed on the gas supply line, and an element that produces the electromagnetic field (EMF) is installed in place of the bimetal plate in modern gas columns.

This valve is forced open by the user upon starting, and an electric current produced by a heated safety element holds it in place.

As you can see, there could be a wide range of reasons for the water heater strike, and they might be concealed in both the device itself and the engineering networks that link it. Examine both in great detail.

Why the gas column does not light up

The purpose of a gas water heater is to provide hot water for residential and commercial buildings. When used properly, a complicated but dependable device can function continuously for a very long period. However, it can happen at any time that the gas column doesn’t light up. The main nodes’ existence and the mode of operation are independent of the equipment’s make and model. There may be variations in the way things look and the additional features they offer.

The following components make up the column’s design:

  • Frame
  • Traction saboteur (to stabilize traction)
  • Heat exchanger
  • Burner (serves for the formation and uniform distribution of flame)
  • water node (opens a gas valve and regulates the amount of liquid)
  • Gas node (regulates the flow)
  • Control block
  • Sensors.

The main burner’s burning gas heats a copper tubular heat exchanger with ribs that cold water passes through. Traction-related combustion products are redirected into the chimney.

Reasons why things break and how to fix them

Businesses selling gas equipment ought to be shut down by specialists with limited experience. However, there are some malfunctions that can be fixed by hand, such as repairing a gas column. In any case, the cranes’ gas and water supplies must be cut off before the fasteners can be undone and the device’s handlebars and shell can be taken off.

Typical circumstances in which there is no light in the gas column:

1. Nutritional elements are released in columns using automatic ignition. In contrast to the manufacturers’ approval, the purpose of the batteries is to maintain the electromagnetic valve open during operation, which means that they need to be changed more frequently and their service life does not reach a year.

When it comes to speakers that have an integrated generator, the reasons why the gas burner isn’t producing sparks could be due to issues with the electrode, the piezoelectric element, or damage to the supply cable. After cleaning the automatic ignition contacts to prevent oxidation, the electrode and wire are inspected for gaps both inside and outside. The inclusion button and piezo element may need to be replaced if the steps taken have not completely stopped the breakdown.

2. Using a lit match brought to the well of a gas column, it was determined that there is no traction. Should the flame not veer toward the grate, it becomes imperative to have the ventilation passage cleaned by experts.

3. Inadequate pressure, which prevents the column from sensing the duct. The heater node or the water supply could be the source of the problem. It is advised to clean, rinse, or replace the filter in the pipes.

4. The rod is moved to the gas supply when the duct’s speed bends the water node’s membrane. After three years of use, the rubber plate may develop defects that cause it to stretch or get damaged, which will prevent the gas water heater from starting.

It only takes removing the gas and water unit, separating the water portion, and carefully opening it like an oyster by unscrewing six screws around the circumference to replace the membrane. It is preferable to pay close attention to the location of any rubber parts before removing them. The inside of the lid needs to have its cavities cleaned of pollutants and a new membrane installed; it should use a rod to "hug" a plate. It is preferable to use silicone in place of the plate because it has a far longer service life. The connecting screws are twisted diagonally to guarantee a uniform clamp.

5. "Water duct regulation" is a feature of some species. For instance, if the mechanical switch is set in the incorrect position, the Neva 4510 gas column will not ignite. The handle is inserted in the far left position and moves to the right until the device turns on if the tap’s pressure speed is good but not high enough to activate the water heater. Typically, the stream adjustment is done only once when first starting.

The safe operation of the gas column is crucial for the comfort and safety of the user. In addition to keeping hot water equipment in top operating order and averting costly repairs and complicated breakdowns, routine maintenance also helps to prevent emergencies that could endanger lives or cause serious health problems.

Typical breakdowns

Issues can vary between manufacturing companies’ units, and many of them are typified by the emergence of specific malfunctions over time.

  • "Aster" – does not turn on or turns on from several attempts if the flow of cold water is inaccurately adjusted. The unit valve itself regularly fails. In this case, almost everyone who purchased this column indicates that the main drawback is the lack of automatic ignition, which is why you have to keep the fanner on, which quickly stops working if it is offered or moved.
  • "Ariston" – a water block breaks, the membrane is easily deformed. Customer reviews are mostly positive, people note that the column is lit quietly, well maintains the temperature and has an affordable price category, and is also easily controlled.
  • "Oasis" – faulty burner, which needs to be often replaced, deformation of the membrane. Buyers are attracted by price and design, but otherwise they often say that the device breaks quickly, batteries fail, the column itself almost does not heat water and requires frequent a water filter replacement.
  • "Amin" – lights up several times and turns off before heating, the batteries quickly sit down. Users note a combination of the low price and good quality of the column, but they are not satisfied with the fact of frequent replacement of batteries. As a plus also note the presence of a special scoreboard that displays the temperature.
  • "Russian ms" – often failing a valve block, quick clogging of the filter system. Reviews show that the column slowly lights up with a weak pressure of water, the liquid temperature itself jumps when the tap is switched to a shower, and the device quickly goes out.
  • "Dion" – The body of the heat exchanger is burning. There are almost no negative reviews here, buyers are satisfied with the simplicity and ease of use, the design of the column, the security system and the fact that the unit can work for a long time.

We can conclude that every gas column has a unique set of drawbacks related to its various components, poor manufacturing quality, the manufacturer’s own carelessness, and other factors. It is best to speak with experts or production masters before making a purchase.

Users claim that certain models not only malfunction frequently but also pose a major risk to life, so it’s important to weigh the advantages and disadvantages.

If the gas column does not light up

Gas columns are a reasonably dependable water heating system. The column can function quite simply in theory and, with the right care, will continue to function continuously for a considerable amount of time.

But occasionally, the gas column can malfunction for entirely different reasons. They may be linked to both external factors unrelated to the column’s issues and infractions pertaining to the operation of the gas column’s nodes themselves. The inability to light a column is frequently the primary symptom of an issue. So, the following factors may be at play if the gas column does not light up.

Common circumstances and reasons

The most frequent cause of the column failing to ignite is lack of traction. The most frequent cause of this situation is an obstruction in the air duct. It is very easy to check for traction by placing a lit match against the duct bell and directing the flame toward the direction of the air flow. The only way to clean air ducts is mechanically.

Windows that are closed too tightly may result in inadequate thrust. The result is a disruption in the air’s natural flow. In this sense, the overheated protective relay—which is fitted in certain column models—sets off the overheating protection mechanism. In this case, the column shuts off right away after a short while of operation. In this situation, opening the window or turning it into ventilation mode is required.

Another frequent and typical reason is insufficient water pressure. Furthermore, the design of the water supply system itself may be the reason for low pressure. Simply put, the pressure is insufficient on its own, and the only way to fix this is to swap out the column for one that can function even with very little water pressure.

However, if the lack of water is the reason why the gas column does not light, the issue might be related to the device’s water unit malfunctioning. For instance, a metal mesh filter that is placed in front of a gas column’s water unit block on a pipe may clog.

Lime deposits that build up on the mesh filter during water flow are the cause of the clog. To check the amount of clogging in the filter cells, simply spin the nuts. Additionally, there are two options: either purchase a new filter or clean the old one (which is not that hard to do).

A membrane defect inside the water unit could be the source of the issue. The only way to find out this is to take the cover off the block. Only a few of the screws holding the lid on need to be undone. Beneath the lid is a rubber membrane that should be free of rips and obvious dents.

The cause of the column’s malfunctioning operation is most likely the membrane if it is a single, stretched membrane. The new membrane replaces the old one. If the membrane was made of rubber, you could replace it with one made of silicone. The silicone membrane has a far longer lifespan than rubber.

In order to prevent deformation during installation, it is crucial to correctly install the membrane. To do this, the screws are twisted in the opposite direction from the order in which they are fastened, gradually squeezing the water block lid.

A gas column with automatic ignition that doesn’t light up could have as simple a cause as sat batteries that provide an electric pulse to the column’s rod. Additionally, the batteries may need to be changed sooner than the instructions specify.

In this instance, changing the batteries is sufficient. But initially, nothing will happen while the batteries are idle. However, it occasionally happens that the wick burns, after which either nothing happens at all or the column starts to function and instantly enters the wick’s operating mode.

The reasons for the column’s inability to start have already been disclosed, but there might be more issues. For instance, issues with protective valves, gas supply valves, heat exchanger tube blockage, and buttocks on different nozzles could arise.

Naturally, you can handle these issues on your own, but any gas equipment needs to be handled by a professional. As a result, you should contact gas service experts if the gas column is not lighting and the cause is unclear.

Когда Вектор зажигается с запозданием

Here, too, there are multiple variations. In this case, opening and cleaning the unit—especially the nozzles—is the first thing that must be done. If none of the above worked, you should try the following in order to identify the point of failure:

  • Electronic ignition unit
  • The traction sensor
  • Microsword
  • solenoid valve.

It is necessary to short the microswitor in order to check its working capacity if there is a crack but no spark with roser.

Vector of microswater in a gas column

First, you have to take off the casing. To do this, pull the handles and take them off. Then, unscrew the two screws on the left and right from below. Lift the casing until the pins at the top by pulling the bottom of the column on yourself. The outer shell is taken off. A microswell is located in the lower part of the center. Once the hot water crane is powered on, a lever will release the switch button from its submerged position. If not, it needs to be pushed with a screwdriver and lubricated. One last thing to do is remove a roser.

Should this fail to occur, a replacement microswell is needed. In instances where a spark occurs and no ignition occurs, the electromagnetic valve is rendered inoperable. You should replace it as well because it won’t be able to be repaired. It is required to inspect the electronic ignition unit if there is no spark, no cod, and no clicks but the microswitch is verified to be operational. This block is hard to repair; replacement is necessary.

We recommend reading through the content of the article on column repair as a way to assist. Additionally, the following video provides more details on changing the rod:

While some of these issues are self-solvable, others result from misuse of the device or disregard for the usage guidelines. In any event, it should be considered that if the issue involves gas equipment, it is best to leave the repair to the experts, particularly if the unit fails to ignite and the cause is unclear.

Lack of traction in the chimney

Presence of this reason usually means that the column will eventually rot. It is easily detected by bringing a lit match or stick up to the viewing gap on the front panel. The match’s flame is drawn inside when everything is in its proper place, and this is evident to the unaided eye. The second step is to disconnect the chimney from the mine shaft and repeat the check while bringing the match to this hole if the flame does not move. Once more, there is no traction? There could be two causes:

  • The vertical mine is blocked by extraneous objects or packed with soot;
  • In the room where the heater is located, there is no air flow, and without it there is no hood and the column goes out.

I have to admit that the first reason doesn’t come up very often. Furthermore, it is not possible for a craving to exist for years before abruptly ceasing. Unless, that is, someone deliberately dumped trash down the mine. Particularly during the summer, soot builds up gradually on the inner walls and causes a slight decrease in traction. But, you need to confirm that the room enters the room before calling the stoves to check the exhaust shaft.

The house’s old wooden windows were replaced with metal and plastic, which causes the heater to stop working. The thrust vanishes as a result of the street’s air flow overlapping.

To ascertain whether there is no influx, carry out the same procedure using a match and an open window. If the craving did arise, make sure the room is properly ventilated; avoid sitting with the windows open all the time.

Additionally, there are times when a craving exists in the mine but not in the column’s observation window. Therefore, the device’s gas air tract is the cause. These are typically heat exchanger soot ribs that are almost completely airless, preventing the device from operating normally. The traction sensor’s failure is the final factor related to the chimney. It is preferable to call in an expert to replace it and clean the heat exchanger.

Prevention

Follow these guidelines to avoid having to fiddle with the unit too much or call the repair service frequently.

  • Set the temperature at the optimal level so that there is no need to dilute water, then the scale will not appear so fast. In order not to have to regulate the column every season, it is preferable to choose a model that memorizes tuning for winter and summer modes.
  • To remove salts from water with high stiffness, you can install an electromagnetic system that will clean the liquid.
  • It is necessary to regularly clean the chimney and parts of the water heating system.
  • Modern speakers, which have a built -in electronic controller, are best connected to the network via a stabilizer and not turn off at night.
  • If the hose in length exceeds 3 meters, then the pressure during gas supply will decrease greatly.
  • When working, the column is better to open the window, such a simple way will allow you to get a lot of air for the normal functioning of the unit.
  • The chimney and the rapidly dusty parts of the column should be periodically checked for the presence of dirt, web and the like things and get rid of them using brushes and vacuum cleaners.

Indications that it needed an expert’s technical inspection and unscheduled preventive measures:

  • The pressure in the water supply is normal, but the heat exchanger still works a small amount of time;
  • The unit is constantly turned off or does not function in principle, although gas and water is supplied in optimal mode;
  • Often, for no reason, thermal protection provokes a shutdown of the working system;
  • the heating of water is reduced, although there are no disabilities notable to the eye to the eye.

You must remove the upper body in order to inspect the column from the inside. This is accomplished by unscrewing the screw on the handle of the gas lock crane mount with a cross-shaped screwdriver. Stretching removes the pen itself. The housing can then be removed by unscrewing the screws that held it in place with a flat screwdriver.

The primary responsibilities of planned prevention include evaluating overall performance, examining the column from the inside out to identify areas that need to be cleared of dust and debris, and precisely determining the heat exchanger’s state.

Periodic prophylaxis and verification allow you to increase the life of the apparatus due to the timely detection of problems in the functioning of the column. The work itself should usually be carried out once a year, but if the column is already old and often junk, then if it is impossible to replace the check, it is worth arranging more often. It is better to trust the annual audit to professionals from specialized gas services, since they will be able to determine exactly the condition of the unit is located. High -quality maintenance usually includes a complete analysis of all equipment, the search for defects and areas with damage, which can cause interruptions in the operation of the columns. Each main part (wet and dry cleaning), regulation of all components of a gas water heater or their drive to the original position, reverse connection and testing of readiness for work are also carried out.

The following video will cover the primary gas column malfunctions.

The gas column does not ignite

Reason 1. There is not enough traction

Soot in a chimney or an unnecessary object could be the source of the issue. In this instance, the water heater’s protection mechanism is activated, causing the gas to automatically blow, and the thrust to be reduced.

To verify the assumption, simply open the window, place your palm over the chimney opening, or strike a match close by. There will be a discernible breath and a noticeable deviation in the light if the craving is good.

Cleaning the ventilation channel is the solution. It is unable to complete the task on its own. Call chimney sweepers and the management company, please.

Reason 2. The supply elements were discharged

This occurs with gas columns that are automatically ignited by power sources such as generators or batteries. This typically occurs 8–16 months after the operation begins.

  1. Check the column.
  2. Change the saturated batteries for new.

Reason 3. Weak pressure of water

To verify the pressure, turn on a cold water tap. Should the flow of cold water be as poor as that of hot, the issue lies in the water supply. The case is in the water node by the column if the cold water pressure is significantly higher than the hot water pressure. It might have had clogged filters or a distorted membrane. Alternatively, it is possible that the deep cleaning system’s installed hot water or filter pipes are clogged.

  1. Call the communal service: they can give an answer there if problems arose throughout the water supply network.
  2. Rinse water purification filters or change the filter in the mixer.
  3. Clean the column from soot and soot.
  4. Replace the membrane of the water node of the column.
  5. Leave an application in the communal service for flushing of hot water pipes.

Reason 4. There is no gas supply

Typically, a distinctive sound and the faint scent of the entering gas are detected upon column ignition. Gas does not arrive if there is neither a sound nor a smell.

  1. Call the communal service to find out if repair work is underway on your site: gas could be turned off in centrally.
  2. Check if the gas was paid for: it could be disconnected for non -payment.
  3. Call a gazovik specialist.

Other problems when using a gas column

When utilizing a gas column, additional issues could surface if the apparatus malfunctions or has blatant violations. Potential solutions to fix such issues and malfunctions include:

Diagram of a gas column device.

Pops can be heard, but the gas column turns on. Pop, or Mikrovskvyes, emerges for various reasons:

  • lack of traction for the operation of equipment in the ventilation channel;
  • the discharge of batteries, that is, the ignition simply does not work;
  • Jicks and other structural elements are very contaminated;
  • The influx of gas is too large.

The following techniques can be applied in order to remove such a malfunction:

  • cleaning the chimney with a lack of traction (it is best to call a specialist, and not try to do this work yourself);
  • replacement of batteries with non -working ignition;
  • For repair in other cases, it is necessary to immediately contact the gas service, the gas column must be turned off, and the gas supply is blocked.
  1. When the equipment is turned on, a strong smell of gas occurs. This is a clear sign that the column is faulty, since the equipment should in no case smell of gas. If such a situation arose, then you need to immediately block the supply valve, open the windows to ventilate the room, call the gas service to determine the malfunction. Do not try to repair the device yourself, as this can lead to the explosion.
  2. When turning on, there is no gas supply. At the time when the gas column turns on, the characteristic sound of the incoming gas should be heard, that is, a slight hissing. If the column does not ignite, then listen. If there is no sound, then the gas mixture simply does not act. Such a malfunction involves this procedure:

  • The column must be turned off, the gas supply from the pipe is stopped (it does not matter that you can’t hear the sound, the tap must be blocked);
  • After that, you should call the appropriate gas service to find out if any work is being carried out on your site, which involve gas disconnecting;
  • If there is no repair, that is, gas in the highway is supplied properly, it is necessary to call the master who will examine the condition of the column, perform the necessary repairs if the gas column is subject to the repair.

Automatic gas column does not light up

Make sure the v. / Off. is in the first position if the smell burner is not sparking. Use the sowing batteries if a red light bulb blinks when the column is turned on. Purchase fresh food and swap it out. An error in the functioning of an automatic system is indicated by a blinking red light in the Vaillant column. In this instance, the servomotor bears the brunt of the malfunctions.

The locksmith most likely misinterpreted the entrance and the water release if the column remains off following plumbing work done on the apartment (replacing pipes, installing a new column, or installing a central riser). Verify that a malfunctioning mixer isn’t causing the water duct to become mixed. Open the hot water tap and disconnect the water heater’s cold water supply. In order to replace the mixer, you must contact plumbing if the water originates from the tap.

The gas column won’t start if the water pressure is low. The water flow drops to 7 liters per minute when you turn the temperature adjustment handle clockwise to the stop, increasing pressure and turning on the column. The water consumption rises to 13 liters per minute when you turn the handle counterclockwise to the stop; the pressure falls and the column does not turn on.

The water flow will be restricted if the filter element is dirty. The first thing you should do is clean the filter of any dirt and rust if the gas column fails to ignite the weak pressure. This is particularly true following plumbing and supply pipe replacement work.

Microswell with faults. When opening the mixer’s crane and hearing no clicks from the burner’s ignition, you should get in touch with our business for gas column repair services. Our technicians will fine-tune the mechanism, which has significant wear.

The interior of the water reinforcement should be spotless. For the first three or four years of operation, the reinforcement will rust and clog if the water is hard and contains a lot of lime. In this instance, it ought to be swapped out for a brand-new one or fixed entirely, including the replacement of all rubber parts. The membrane should be fully replaced if there is even the slightest suspicion of tiny cracks or holes in it.

The column will likewise "be silent" if the cliff is in the electrical circuit. Examine the column’s automation and, if required, swap out every damaged component. Our masters can assist you in fixing it; all you need to do is get in touch with the business’s operators and submit a repair request.

Causes

It is important to keep in mind that breakdowns can occur in a variety of ways. As an illustration:

  • The flame did not light up (clicks, there is a spark, but or not no reaction to inclusion in general);
  • goes out immediately or by the incident of a short time (both with automatic and with manual ignition);
  • The fire goes out when trying to turn on water, strengthen the pressure or its weakening;
  • The flame is lit, the water is slightly warm, and then the column goes out;
  • The column claps, cracks, mini-explosions appear when turning on;
  • piezo -Zhizhig does not work;
  • Pierge is constantly working, but when igniting, the flame is extinct;
  • The automatic column does not burn, while the smell of gas is underway;
  • When opening the tap, the stem does not move.

The column’s malfunctions can be classified as either entirely internal or as a result of external influences. The former rely on extra information or exposure from the outside and are unrelated to the details within the unit itself (for example, adding temperature).

The second occurs if there is a malfunctioning or clogged component within the device.

External factors

These are the breakdowns that occur externally.

  • The most common situation is Lack of traction in the chimney column. If you do not clean it, then it will be clogged with dust, dirt, and combustion products will not find the withdrawal and extinguish the burner. Then, when the security system is triggered, gas supply will be blocked.
  • The chimney accidentally could be An extraneous subject.
  • The unit could just discharge a battery or battery. This type of malfunction exists only in the presence of ignition, which automatically acts on batteries.

  • If the device does not work, after the first installation or due to repair work with the tap system, that is, there is a high probability that The hot water supply line was simply connected not where it should.
  • Reduced water pressure. It is necessary to evaluate the water supply (it will be weakened, the water is overlapped with a thin stream). The ignition will stop working with weak pressure, so the reason is no longer in the column, but in water pipes. Although, it is likely that the filter installed in front of the column is clogged.
  • Failed mixer, adding too much cold water, so the water in the column itself heats up too much and extinguishes it.
  • Electronics. In modern columns there are a large number of control modules and sensors that control the work of the entire unit. Their malfunctions can lead to the fact that the gas will cease to ignite.

Internal breakdowns

There are internal factors.

  • Incorrectly configured water heater. Due to the change of seasons, the water temperature also changes, so the column must be adjusted, which is often forgotten to do.
  • The membrane on the water node failed. If the membrane for many years, then she could lose elasticity, crack, deform, cover with lime deposits.
  • Zakor filters or heat exchanger soot and scream.
  • The smalle or main burner turned out to be Closed with mud.
  • Problems With a gas output sensor.
  • Clap or small explosions When trying to enable equipment, they may occur due to insufficient thrust in ventilation or blockages of different parts of the water heater.

The ignition button not being fully held when turned on could be a separate source of the issue. It needs to be held for roughly 20 seconds before it goes out.

Water supply problems

The pressure will drop to the point where the column cannot ignite if the blockage in the heater spreads to the input mixer. In this case, there is nothing more that can be done without acting quickly. In this scenario, you must disassemble the entrance node entirely and use a rubber hose to wash it with running water right away. The gas column’s filter and its surrounding components are cleaned at the same time.

Thus, neglecting to take care of household appliances on time is the root cause of low water pressure and one of the reasons the column started to shut off. For this reason, specialists advise preventing it on a regular basis (at least once a year).

Low highway pressure can lead to issues with the water supply. However, in this instance, the customer has very little influence and is limited to trying to add a second pump to the system. But only private home owners are allowed to use such a tactic. You can file a complaint with the service provider in apartment buildings.

Internal breakdowns

The water heater itself may experience the following issues:

Ignition system does not work

There could be no breakdown at all.

Batteries may run out of power if they are the source of the spark.

Despite the manufacturer’s claims of a longer service life, experience indicates that the batteries in the column need to be changed approximately once a year.

When starting, if the user did not hold down the forced gas supply button for a prolonged period of time, the column with a faint may go out. There was not enough time for the safety element to fully warm up and set the gas valve to the "Open" position.

The water heater is incorrectly configured

The water’s temperature at the column’s opening determines the performance that is needed. The device’s gas regulator needs to open slightly more during the winter months because the water in the water supply cools down. However, the water temperature rises by several degrees during the summer, necessitating the screwing of the column. However, users do occasionally overlook this. The water heater overheats and is consequently turned off almost instantly.

Select a model with memory settings and winter modes to avoid having to deal with the column adjustment before each season.

The water knot membrane failed

This is collapsing already. The membrane may have developed in the following ways:

  • loss of elasticity due to aging;
  • the appearance of cracks or deformations;
  • overgrowing with lime deposits.

After the water node has been disassembled, the membrane must be examined; if it appears noticeably abnormal, the element is replaced.

The heat exchanger clogged

The heat exchanger is constructed from a tube with a narrow passage section to maximize efficiency. And this element quickly becomes clogged with a scope if the water has a high concentration of hardness salts. You can definitely get rid of it on your own. It is preferable to use a tool made especially for the speakers in order to avoid having to disconnect the heat exchanger.

You can make the composition at home by dissolving 100 g of citric acid in 0.5 l of water; it’s not necessary to use the one you bought.

Soot accumulated on the heat exchanger

The security system responds to this phenomenon by causing the thrust to deteriorate. The simplest way to remove soot from the heat exchanger is by using a vacuum cleaner, but first you need to take the column’s casing off.

The main or smell burner clogged with mud

On a weak flame with a yellow cone at the top, you can make an educated guess. When there is dirt present, the main burner may only partially burn. You should contact a master in this case, who will clean the burners and replace them if needed.

What to do if gas does not enter the gas column

The main burner of gas equipment is unlikely to leak gas if it does not light and does not emit the distinctive sound or smell. Why is this possible? The gas shut-off crane must first be checked; it should be 90 degrees open.

Additionally, low gas distribution system pressure could prevent fuel from entering the column. Contact Gorgaz to find a solution to this issue. Gas workers are able to increase pipeline pressure to a height of 300 mm above a water column.

It is not advised to solve this type of issue on your own. If the gas does not enter the gas column, the issue might be related to pipeline malfunctions.

The incorrect connection of the column to the gas pipeline may be the cause of the fuel supply issue for the gas water heater.

So, only use a special tee to cut a gas column into a gas pipeline. You must ensure that the connection is tight if the gas is summed up through a flexible hose. Furthermore, the hose should not bend in any way as this could endanger people’s lives and health.

Possible reasons why the column does not ignite

Although the gas column is very dependable, equipment of the highest caliber occasionally breaks down. Of course, the column can go for many years without needing any repairs as long as it receives appropriate, on-time maintenance. But things break down sometimes. When the equipment is turned on, why might it not ignite?

When the column turns on, does the flame ignite or does it just go out right away? The ventilation channel’s apparent lack of traction is the cause. This could happen if there is an object blocking the channel or if combustion products have accumulated.

The water heater’s unique safety mechanism is activated if there is no traction, which causes the gas supply to the burner to automatically shut off, thereby stopping the flame rowing.

Diagram of the connections in a gas column.

Check if the lack of traction was the cause of such a malfunction, you can independently. To do this, the window opens in the room where the column is located, a lit match or just a palm is applied to the hole of the chimney. If there is a craving, then the flame of the match fades or deviates, and the palm will immediately feel the movement of the air. If this does not happen, then there is no traction. What to do in this case? Malfunctions can be eliminated by channel cleaning. But it is not recommended to do this with your own hands, it is most correct to call the service organization right away, to call a gazumor.

The device’s automatic ignition system’s power elements being completely discharged is another reason why the column does not ignite when it turns on. If our system is similar, keep in mind that the batteries or generator are frequently discharged, even though the manufacturer claims that you won’t have to worry about them changing for a year. Experience demonstrates that nutrition components are changed far more frequently than once a year. It’s easy to check the battery category; all you have to do is press the inclusion key. If the panel doesn’t respond, replace the discharged batteries with new ones.

Why the gas column does not light up

1. The gas column is not lit automatically

First, check the power elements (batteries) if the gas column is fully automatic and you do not hear the crackling sound of electric lighting when you open the water tap. Certain Bosch gas column models come with a light indicator that alerts you when a red light briefly blinks, indicating that the batteries are sitting.

Change out the damaged batteries for new ones. If, following replacement, neither the situation nor the column light up, the breakdown may have been caused by a minor automatic job failure. It is preferable in this case to bring in a specialist equipped with the right tools for a complete diagnosis at home.

But what should you do if the gas column suddenly lights up and starts to rush?

2. The gas column with open wick does not light up or goes out after letting go of the button. First of all, pay attention to a burning wick. The flame of the wick should be blue without red species and completely wash the thermocouple installed later. The role of the fragrant is not only the ignition of the main burner when the column is launched, but also the stable heating of the thermocouple. If the heating of the thermocouple is weak – The column is poorly light up. In this situation, the nozzle should be cleaned by the litter of dust and blow all the supply tubes with air. How to clean a wick with your own hands, see this article on the example of a Neva-3208 column.

3. Because of membrane deterioration, the gas column is not illuminated. The very working element of the gas stems, which is continuously under pressure from flowing water, is assigned to the membrane of the water part. The gas supply is opened by the mechanism as the membrane is pressed by water. It is constant loads that cause the membrane to tear. The pressure drops as a result of the openings, and the column stops lighting. Try using your hands to alter the membrane in order to escape this predicament.

Typical situations and causes

Only when every component of the gas flow water heater is functioning properly will it operate as intended. This is what they have listed:

  1. Water circuit: This is just a pipe of a special configuration (heat exchanger) through which water flows. The main condition for this component is sufficient bandwidth.
  2. Gas-burner: will only work if the valve is open on the gas supply line.
  3. Ignition system: This is a device that at the right time sets fires gas coming from the burner. If it is boring, the column, of course, will not be able to turn on. In some ignition systems there is a duty burner (Selloille).
  4. Smoke removal system: On the path of combustion products from the burner itself before reaching the atmosphere, there should not be insurmountable obstacles. The main part of this system is not a component of the column – it is a vertical or horizontal chimney that goes out into the street.
  5. Automation: This system includes a whole set of devices and sensors, and all of them control the operation of the gas valve.

One type of automation is mechanical.

  • a membrane mounted in a water circuit and associated with a gas valve. Reacts to a change in water pressure;
  • Bimetallic plate. If the burner on duty suddenly goes out, the plate will cool and block the gas supply.

… as well as electronic

  • The traction sensor: blocks gas supply if there is a danger of getting products of combustion into the room;
  • A flame sensor installed in the columns without a duty burner: it works when the main burner is faded;
  • Overheating sensor.

Any of these systems’ operational infractions take the following forms:

  • The burner does not ignite at all;
  • The flame flashes, but immediately goes out (the gas column lights up and rises);
  • It is not possible to light a smell.

Examine in greater detail the causes of these kinds of phenomena.

It can be very frustrating to have a gas water heater that won’t light. On the other hand, you can avoid risks, waste money, and waste time by learning the common causes of this problem and how to solve it.

First and foremost, you must make sure there are no leaks or disruptions in the gas supply by inspecting it. Examining the gas water heater’s wick comes next, assuming the gas supply is still operational. The wick may get dirty or worn out with time, making it difficult to ignite properly. Your water heater’s functioning can usually be restored by cleaning or replacing the wick.

It’s also important to make sure there are no obstructions in the burner assembly or gas line. An obstruction in the gas flow caused by debris or buildup in these areas can result in an ignition failure. Such problems can be avoided with routine maintenance, which includes cleaning the burner assembly and making sure there is enough ventilation.

In the event that wick troubleshooting and blockage checks prove ineffective, professional help may be required. A skilled specialist can conduct a comprehensive examination of the gas water heater to find any hidden problems and carry out the required maintenance or repairs.

In conclusion, a gas water heater that won’t ignite can be a frustrating issue, but with the correct approach, it’s usually a manageable one. You can guarantee dependable operation and safety in your home by being aware of the typical reasons for ignition failure and taking preventative maintenance steps for your water heater.

Video on the topic

The gas column does not light up.

The gas column does not ignite- we eliminate in 5 minutes.

Bosch gas column does not ignite. The wick goes out…

The gas column rises or does not light up

What type of heating you would like to have in your home?
Share to friends
Anna Vasilieva
Rate author
vDomTeplo.com
Add a comment