How to enable the gas column – the rules for launching a gas flow water heater

To ensure efficiency and safety when launching a gas column, also called a gas flow water heater, great care must be taken. Because they are economical and convenient for instantaneously supplying hot water, gas water heaters are widely used. On the other hand, poor installation or operation can present significant risks, such as carbon monoxide poisoning and fire hazards. We’ll walk you through all the necessary procedures and safety precautions in this guide to correctly enable your gas column.

Prior to getting into the specifics of starting a gas flow water heater, it is important to stress how important it is to comprehend your unit and its parts. Read the instructions and specifications that came with your gas column from the manufacturer. Being aware of the features and requirements of each model is essential for safe operation, as they may vary slightly.

It is essential that you conduct a comprehensive inspection of the unit and its surroundings before turning on the gas flow water heater. Look for any indications of leaks, corrosion, or damage in the venting system, connections, and gas lines. To avoid dangerous gases building up, make sure the space where the gas column is installed has enough ventilation. During the inspection, if you find any problems or irregularities, stop and speak with a trained technician.

It’s now time to get the gas flow water heater ready for use. Make sure the gas supply valve attached to the unit is closed before proceeding. This keeps gas from entering the heater while it’s first being set up. In order to let water enter the unit, also confirm that the water supply valve is open. Verify again that the device is plugged into a grounded outlet and that all electrical connections are tight.

After making all the required arrangements, you can turn on the gas supply to the water heater. When the unit’s gas supply valve is carefully opened, listen for the sound of gas flowing. A faint hissing sound is typical when the gas enters the system. But if you notice any strong or strange smells, turn off the gas supply valve right away and get help from a professional.

Once the gas flow is enabled, ignite the gas column’s pilot light or electronic ignition system by following the manufacturer’s instructions. In order to properly ignite the burner, you may need to make several attempts, so proceed with caution and patience. Watch the device for any indications of malfunction or abnormalities in operation as soon as the pilot light or ignition system is turned on.

Now that the gas flow water heater is turned on and working, it is crucial to give it regular upkeep and inspections to guarantee its efficiency and safety. Keep an eye out for any wear, corrosion, or leaks, and take quick action to fix any problems that you find. You can safely and effectively enjoy the convenience of hot water from your gas column by adhering to these instructions and using caution at all times.

Step Description
1 Check for gas leaks using soapy water solution.
2 Make sure all gas appliances are turned off.
3 Open the gas shut-off valve fully.
4 Set the gas control knob to "pilot" position.
5 Hold down the pilot button while igniting the pilot flame.
6 Keep holding the pilot button for about a minute.
7 If the pilot stays lit, turn the gas control knob to desired temperature setting.
8 If the pilot doesn"t stay lit, repeat steps 4 to 6.

When you need to turn on the column

  • Columns with a constantly burning wick – the ignition is performed at the beginning of the day. Most consumers set fire to the wick in the morning and leave it to work during the day. After ignition, the column is completely ready for work. The first inclusion occurs with the opening of the hot water tap.
  • Columns operating in automatic mode (not having a wick) – are turned on independently, after the opening of the hydraulic tank is opened. Classic models refuse to work if there is no pressure in the pipeline. In modern water heaters, inclusion at low water pressure (0.3 atm) occurs.

All types of flot gas water heaters share the same disadvantage: time passes between when the DHW crane is opened and when the user receives hot water. Before it reaches a certain temperature, it takes several minutes.

There is a serious breakdown if the column is difficult to turn on, the burner and wick go out while the device is operating, and there is a gas smell in the piezoelectric element’s field. To fix the problem, turn off the water heater, shut off the gas, and contact the master.

Rules for the inclusion of gas water heaters

It is crucial to take safety precautions when using the column. Follow the manufacturer’s instructions to the letter when using the main burner or filter.

  • Modern columns have several levels of protection and work mainly in automatic mode, without requiring special precautions. Ignition and inclusion occurs when the hot water crane is opened.
  • Problems and difficulties arise when using old columns that need to be set on fire with matches or models with built -in piezoelectric element.

How to turn on the old column with matches

There are two primary varieties of water heaters, with variations in the igniting device. Every single model comes with a smaller wick that is continuously burning. The initial Stalino and Khrushchev residents had to operate a column equipped with levers. Subsequently, piezoelectric arsonists integrated into water heaters were developed.

Take caution when using the old-sample gas column. Failure to follow the guidelines outlined in the operating instructions may result in an explosion, a gas leak, or equipment failure. The following guidelines are followed when the gas water heater is turned on:

  • Checking the availability of traction – before turning on, make sure that carbon dioxide will be able to leave the room freely. Air circulation is checked using a strip of paper or a lit match.
    In the case of the column, an audit hole is provided. A piece of paper brought to it must be attached to the water heater body. The tongue of the flame should be pulled into the hole.

  • The lever of the column (in the late models is replaced by a pen) is shifted to the left position to failure.
  • Clamping the electromagnetic valve button. At this moment, the wick is simultaneously painted with matches. After 15-20 sec. The valve is released. The smell must continue to burn. It happens that the wick is turned on only the second time. The reason for this malfunction in failures in the operation of the electromagnetic valve.
  • Open water in a bathroom or kitchen sink.
  • Quickly transfer the right lever to the left position. The main burner should light up. The lever is adjusted to the temperature of hot water.

Lighting an antique gas column is not that hard. switching off in the opposite direction. Water is overlapped after the main burner is turned off.

How to light a column with a piezo element

Traditional columns with lever-operated controls were swapped out for models that had handles-shaped mechanical switches. The gas column could be lit without matches thanks to the piezor-Zhizhig of a wick that was included in the case. The following is the ignition order:

  • Electric valve is clamped-usually enough 15-20 seconds., so that there is enough gas for ignition on the wick.
  • It will be necessary to press 2-3 times on piezoelectric element. With a properly exhibited and serviceable module, it is enough to “click” with a piezo element once to light a wick.

The next steps are the same as if you were lighting a column with matches. In the event that the piezo element malfunctions, the matches are used to ignite the device.

How to light a column with electric bank

Individuals who have experience with automatic gas and storage water heaters are aware that, unlike older models, simple adjustments are not required from the user. Automation has been incorporated into contemporary gas water heaters to provide a signal to activate when a hot water crane is opened.

The automatic ignition system, which draws power from batteries or power grids, is the cause of the spark. A burning device can be started in a matter of seconds, providing the customer with hot water, subject to the water heater’s serviceability.

Why does the column turn on by itself

No matter the year of release, every water heater has an automation system that keeps the appliance from igniting on its own. Thus, circumstances in which the gas column itself activates in the absence of water are not included. This is the fault of the water regulator "Frog."

If a gas column appears on its own without any water, there might have been a leak in the hot water pipeline somewhere, possibly in the wall. The issue will go away once the leak is fixed.

Users are far more frequently confronted with the fact that the column keeps working after it overlaps the crane than with the fact that it turns on by itself without water. The water regulator’s internal diaphragm, which is filled with hard water, is the cause. The membrane continues to press on the stem that opens the gas supply even after the hot water is disconnected, showing no signs of hurrying back to its original position. Replacing the diaphragm will solve the issue.

We will guide you through the necessary steps to safely and efficiently start up your gas flow water heater in our guide, "How to Enable the Gas Column." Knowing these guidelines is essential for keeping your house warm and functional, regardless of whether you’re a first-time homeowner or just want a refresher on the procedure. We’ll go over everything you need to know to make sure your gas column activates smoothly and without any hazards, from looking for gas leaks to properly ventilating the area. Now let’s get started and make sure you have the knowledge necessary to maintain the safety and comfort of your house.

Is it possible to turn on cold water when the column works

This is definitely not advised for a number of reasons:

  • At the same time, manufacturers are prohibited to turn on cold and hot water, as explicitly said in the operating instructions. It is necessary to initially set a comfortable temperature that allows you to do without. The opening of the CVS crane affects heating and causes the rapid failure of the water heater.
  • The main reason why it is impossible to turn on cold water when the gas column works is that this violation of operation leads to a rapid increase in scale in the heat exchanger.

The Winter-School mode is included for ease of use in contemporary automatic gas running columns. This feature aids in rapidly adjusting the heating temperature and minimizes gas usage.

Although operating a gas flow water heater may appear simple, it involves following the right procedures and paying close attention to safety. Above all, make sure you are familiar with the manufacturer’s instructions that correspond to the model of your gas column. These rules are intended to protect both your safety and the smooth functioning of your appliance.

It’s crucial to check the gas flow water heater for any wear or damage before attempting to turn it on. Look for any leaks, corrosion, or strange smells that might point to a problem. If you find any problems, stop using the appliance and get help from a professional to fix the problems.

Make sure the area surrounding the appliance is well-ventilated before starting the gas column to avoid gas fume buildup. Allowing fresh air to flow through open windows and doors lowers the chance of being exposed to potentially hazardous gases.

It’s important to clear any accumulated air from the gas lines before lighting the gas flow water heater. To accomplish this, turn on the hot water faucet that is closest to the gas column and let it run until a continuous stream of water appears. This procedure aids in guaranteeing a continuous and seamless gas flow after the appliance is ignited.

Lastly, be sure to carefully follow the manufacturer’s instructions when lighting the gas flow water heater. This usually entails setting the gas control knob to the "pilot" position, pushing and holding down the ignition switch or button, and lighting the pilot light with a different flame source. Hold down the control knob for a few moments after the pilot light comes on, and then release it.

To sum up, starting a gas flow water heater necessitates paying close attention to specifics and following safety procedures. You can safely and effectively start your gas column for a dependable hot water supply in your home by following the manufacturer’s instructions, checking the appliance for any problems, making sure there is enough ventilation, clearing the gas lines, and correctly lighting the pilot light.

2 / 2

Video on the topic

GAZ34.ru set up the Bosch gas column for the summer period.

Council from Petrovich how to configure the temperature of the water in a gas column!!!

Video Instruction on the use of the EDISSON gas column

How to connect a gas column (water heater).

What type of heating you would like to have in your home?
Share to friends
Anna Vasilieva
Rate author
vDomTeplo.com
Add a comment