Knowing the fundamentals of heating systems is crucial for maintaining a warm and comfortable environment in our homes. The three-way valve is an essential part of many heating systems. Although it may sound complicated, its basic working principle is very simple, and it is a key component in controlling the hot water flow throughout the house.
The primary function of a three-way valve is to regulate the flow of water in a heating system. It accomplishes this by controlling the hot water flow between various system zones or parts. This implies that, based on the heating requirements at any given time, it may prioritize heating some parts of the house over others.
A three-way valve’s installation usually entails incorporating it into the heating system’s piping system. It is positioned carefully to control the hot water flow and make sure that the proper amount of heat reaches every area of the house. Ensuring the efficiency and effectiveness of the heating system requires proper installation.
Understanding how a three-way valve works and where to install it can help homeowners optimize their heating systems for maximum comfort and energy efficiency. Whether you"re looking to upgrade your current heating setup or simply curious about how it all works, delving into the world of three-way valves is a worthwhile endeavor.
The three-way valve | controls the flow of fluid in a system by diverting it in one of three directions. |
Principle of operation: | It has three ports: one for the input, one for the output, and one for diversion. Depending on its position, it directs flow to one output port while blocking the other. |
Installation scheme: | The valve is placed in the pipeline with connections to the input, output, and diverter ports as per the system design. |
- Where this device is used?
- Installation of thermal controllers on heating radiator
- The principle of valve operation in the heating system
- The purpose of the device
- Classification of valves
- Video – device in the boiler group
- Types of executive mechanism of three -way valves
- Budget elements with a fixed water temperature
- How to choose the right three -way valve
- Maintaining a comfortable temperature using a three -way valve for heating
- Qualitative change in the properties of the radiator
- Quantitative control of the heat flow using a three -way tap for heating with a thermostat
- The limit of heat flow adjustment
- Design and functionality of the device
- A three -way mixing valve with a thermogram
- Three -way valves with an electric drive: features and advantages
- The principle of operation of the three -way valve with electric drive
- Three -way valves for warm floor and other use options
- Valve connection schemes to the heating system
- Choosing a three -way valve: features of models of different companies
- Three -way valves ESBE: Installation instructions and features
- Three -way valves Navien: features and advantages
- Danfoss three -way valves: features and advantages
- The scheme of the valve with the saddle mechanism:
- Areas of application
- Best famous manufacturers and models: characteristics and prices
- TIM
- ESBE
- Stout
- Watts
- Installation recommendations
- Installation of the mixing valve
- Video on the topic
- Three -way valve principle of work from www.Watershome.RF
- Three -way electrical valve
- 2, 3 and 4 running control valves
- How the mixing unit for water warm floors works.
- Three -way valves Valtec
- TEPLOMIX Schemes of the gap of trichous thermostatic valve
Where this device is used?
A three-way valve is used in many different applications. Its working principle was previously discussed. Examples of its variations, like an electromagnetic device or one with a thermogram, are readily observed in contemporary roadways, where it is necessary to modify the proportions when combining two distinct fluid flows, but the volume or power should not drop.
The most widely used thermostatic mixing device in daily life is the one that helps regulate the coolant’s temperature, as was previously mentioned. It can be supplied to radiators that heat as well as the pipe underneath. Furthermore, temperature control will operate without any issues if the valve has an automated control system.
Be aware that the heating system uses three-way heating to balance temperature variations. This not only creates comfortable and convenient surroundings, but it also conserves energy.
The bottom line is that you can significantly reduce the amount of fuel used by adjusting the coolant temperature at the heating device’s "return." Additionally, this will increase the system’s efficiency. Installing a valve is just required on some systems. For instance, the "warm floor" system prevents users from experiencing uncomfortable sensations by not allowing the floor covering to get hotter than is required for comfortable conditions.
These kinds of adjustment devices are also used in water supply systems to achieve a constant temperature in the flow. The most typical illustration is a traditional mixer, where the temperature of the water is changed by opening and closing valves.
Installation of thermal controllers on heating radiator
There are thermal controllers installed on moving traffic bottlenecks. A crane might be necessary for their location, but in this instance, temperature adjustments must be made on a regular basis. The thermostat is more practical in this regard. The required parameters only need to be set once. Moreover, no human is involved in any of the work. The amount of hot coolant available drops during warming and rises during cooling.
The principle of valve operation in the heating system
The device on the left is where the stream meets. It warms up gradually, and at a certain point, a unique fluid in the thermogram starts to expand. In the end, this results in lowering the rod and opening the bottom pipe to allow for a reduction in the amount of hot water from the heating return line. With hot water, it is combined. Warm floors are already experiencing a less hot flow. The rod is lowered and the thermal element is compressed.
The rod keeps falling as the coolant gets hotter. Could sink to the bottom and open the warm pipe, cutting off the hot water flow. This process will persist until the coolant reaches the desired temperature. After that, the upper valve will open, allowing hot water to flow from the front once more.
The purpose of the device
Even with an accurate heat calculation, external factors such as the hot sun, strong winds, or heat-releasing household appliances owned by the owners may still cause excess heat to appear when designing the microdistrict houses within the apartment. There is no way to lower the coolant temperature for a specific apartment because a heat exchanger in a basic boiler is a weak point because it cannot withstand low temperatures. We require a different kind of boiler, which is condensation, but it costs a lot more. You can lower the quantity of hot water that is supplied to the radiator if you have a basic boiler.
For this purpose, a three-way heating valve connection is provided.
Particular scenarios where a three-way valve is used:
- Ground heating (warm floors). On the two valve entrances, the return and filing are supplied respectively. A mixed (cooled) flow goes through the exit. On the rest of the circuit, this is not reflected in any way.
- Maintaining the temperature in the return. The boiler works fine while the water that comes into it is not colder than 600. For this, water from the feed is separated, and part of it is sent to the return for its heating.
- So that the condensate is not going. The water in the heat exchanger should not pass the dew point. Therefore, it is cooling.
- So that the boiler does not overheat. It is achieved by similar cooling.
- The joint operation of the boiler with the boiler – the valve thermostat is triggered when the water in the boiler is cooled below the given level, the mechanism opens.
- If you need a bypass – a parallel path, then the easiest way to use the valve.
Classification of valves
In terms of operation, we observe that there are two types of devices that can exist in the absence of long-term administrations. It might be:
- dividing;
- mixing.
Each type’s characteristics are immediately apparent from its name. The entrance and two outputs make up the mixing device. To put it another way, mixing fluid flows is essential and may be necessary to lower their temperature. This is, incidentally, the best way to configure the desired mode in the "warm floor."
The process of changing the temperature regime is very easy to follow. To obtain the desired indicators at the output, all you need to do is accurately calculate the necessary proportions of each of the current temperature indicators of the incoming fluid flows. Additionally, this device can be used to separate the flow with proper installation and adjustment.
However, the separation valve has one entrance and two exits since it shares one stream between the two. The primary purpose of this device is to divide the hot water flow in hydraulic devices. However, it happens in the strapping of air heaters quite frequently.
Both options are nearly the same from the outside. Upon familiarizing yourself with their drawing within the context, however, their primary distinction becomes instantly apparent. There is a single ball valve on the rod that is installed in the mixing type device. It spans the main passage and is positioned in the middle.
Regarding the dividing devices, the rod contains two of these valves, which are situated on the outputs. They operate on the following principle: when one of them is crushed to the saddle, passage No. 2 is opened, and when the other is parallel to this, passage No. 2 is closed.
The management approach states that contemporary models can be:
- electric;
- manual.
Most of the time, a manually operated apparatus that looks like a regular ball crane but has three output pipes is utilized. However, automatic electrical models are primarily utilized for heat distribution in private homes. For instance, the user can set the temperature regime for each room, and the working fluid will adjust its behavior based on how far away the room is from the heating source. You have the option to pair it with a "warm floor."
Video – device in the boiler group
The diameter of the supply and the system pressure are used to determine the selection of three-way valves and other devices. GOST regulates all of this. Furthermore, it will be considered a flagrant violation if the latter’s requirements are not met, particularly when it comes to the pressure indicator on the highway.
Low-pressure polyethylene pipelines and brass fittings
Types of executive mechanism of three -way valves
Devices with varying executive mechanisms that establish the principle of valve operation are available from manufacturers.
Types of the executive mechanism | The principle of functioning | Devices |
Saddle | Has a rod that makes progressive movements up and down during the work. | The saddle located inside the case is blocked by a cone fixed on the output of the working rod. |
Turning | There is a ball or sector capable of performing rotational movements. | In the process of work, a ball of a special opening closes or partially opens the opening between the pipes. |
Take note! You can safely buy a valve with a rotary executive mechanism for use in your home.
Rotating mechanism devices are pertinent to home systems.
Budget elements with a fixed water temperature
Simple three-way valves of the autonomous type are permitted in suburban homes’ basic heating systems that get thermal energy from TT KOTLLs. He doesn’t require a thermal head with a temperature sensor in order to function, and the rod is absent. Installed inside the case, the control thermostatic element is set to a specific water temperature at the output, such as 60 or 50 °C (as indicated on the case). Operating system and valve with integrated regulatory component
This kind of thermosynthetic crane is always compatible with a fixed coolant output temperature; this setting is not modifiable. Here’s where there are benefits and drawbacks to using this kind of reinforcement:
- The advantage is a lower price than the cost of a unit with a thermogram. The difference is significant – about 30%.
- Disadvantage – you can not regulate the heating of the outgoing coolant. When the element from the plant is 55 ° C, it will always supply water with this temperature of ± 2 ° C.
Suggestions. Examine the solid fuel boiler’s technical documentation thoroughly before purchasing a valve with a simplified design, as it frequently outlines the reverse coolant’s minimum temperature. Further details regarding the application of mixing reinforcement can be found in an independent publication.
In understanding the mechanics of a three-way valve for heating and insulation systems, it"s crucial to grasp its principle and installation scheme. Simply put, a three-way valve regulates the flow of hot water in three different directions. This valve plays a pivotal role in balancing temperatures across various zones of a building. Its operation involves directing hot water either to the heating system, the domestic hot water supply, or a bypass line, depending on the needs of the moment. Installation follows a specific schematic, ensuring proper connection to the heating system"s piping layout. By comprehending the role and installation of a three-way valve, homeowners can optimize their heating and insulation systems for efficient and comfortable living environments.
How to choose the right three -way valve
Simply buy a standard ball valve if the system needs to be adjusted manually. It is not the same as simple. You can guarantee forced regulation of the heating circuit with its assistance.
It is worthwhile to select a three-way thermostatic valve for automatic adjustment, as it has an electromechanical device that lets you adjust the rod’s position. A private home’s temperature can be adjusted by the user provided the thermostat is connected correctly.
When selecting a gadget, consideration should be given to:
- Joining diameter. It can be 2-4 cm. In the absence of a device with the right size, you can use special adapters.
- The throughput of the pipeline showing how much the liquid is capable of passing through the cross section of the pipe over a certain time.
- The possibility of installing a servo drive. In this case, a three -way valve will be able to work in automatic mode.
Adapters should be used when the connecting sizes are not in compliance.
Maintaining a comfortable temperature using a three -way valve for heating
The radiator’s energy release can be modified in two ways:
Manipulations involving liquid flowing through pipes are required in both scenarios.
Qualitative change in the properties of the radiator
You can switch the heat generator to a different mode of operation, which will alter the temperature of the water entering the radiators, to control the microclimate in the space.
With any kind of heating, you can modify the room’s temperature thanks to the three-way valve.
When discussing a country house, you can change the setting on a wall cauldron. But when it comes to the city microdistrict’s boiler room, things are far more intricate.
Quantitative control of the heat flow using a three -way tap for heating with a thermostat
You can change its number even if you are unable to control the radiator’s water’s temperature. Purchase three-way valves for thermostat-controlled heating in order to accomplish this. With the same area of the battery, these devices let you control how much water flows through the radiator. Naturally, this means that, within the system’s power limitations, more or less heat will enter the room.
A mixing valve with three settings and a thermostat
Although a temperature controller mounted on a radiator and a three-way valve for the heating system can be used independently, a combination approach is frequently employed to boost efficiency in the self-contained heating systems of contemporary apartments and private cottages. Purchasing a three-way valve for heating with a thermostat is therefore advised.
The limit of heat flow adjustment
It is crucial to remember that the radiator’s temperature can only be raised or lowered within the predetermined range by the three-way mixing valve’s operating principle. These limitations are determined by the thermal device’s technical attributes, specifically the amount of its maximum heat transfer, and are unique to each radiator.
Design and functionality of the device
Bronze and stainless steel are the two different materials used in three-way valves (TC). Polymer and metal can both be used to make the case. Even so, the latter is not very well-liked.
Varieties of valves
Three holes make up the design: an input, two weekends, and an internal drive that regulates the flows to achieve a specific temperature.
The product functions structurally as a pair of two-way valves acting in tandem. The primary distinction is that the TC controls the intensity of the medium’s duct rather than stopping it. 3x-logo devices, which can be used in conjunction with thermogram Hertz, are distributed to groups based on the "Shtok-Sedlo" and "Gnesdo Ball" adjustment system.
The rod is typically controlled by an electromechanical type drive, and it is installed in the Boiler Potter and other contemporary solid fuels’ thermal processes that are subject to automatic control systems.
Design of valves
The coolant mixture at the supply and return points of the general flow, with the user-specified temperature, forms the basis of the LC’s operation principle.
The device’s inner cavity environment shifts from one pipe to another until the temperature indicator reaches the appropriate size.
A three -way mixing valve with a thermogram
The thermostat valve ensures that the system will operate in an efficient and practical manner. Three-way heating valves are made to control the flow of heat, ensuring both user efficiency and comfort in the space.
Thermal calculations are done prior to starting the heating system design process. Based on the findings, the kind and power of heating equipment that will best maintain the ideal temperature range in the space are chosen.
The room’s area is considered first, and then any potential heat loss is examined. In light of this, the heating system’s performance is required to establish a cozy microclimate in the rooms. Following that, a thermal balance is compiled for each room.
Nevertheless, the conditions under which these computations are performed may vary while the system is in use.
-
The factors affecting the operation of the radiator are different:
The room gets hot as a result of the calculated temperature balance being upset. It is not feasible to block out heat radiation or remove a portion of the radiator from the room, though. Controlling the energy produced by thermal devices becomes essential as a result in order to keep the room’s microclimate comfortable.
-
There are two ways to adjust the energy released by the radiator:
If, however, you are unable to control the radiator’s water temperature, you still have the option to change its number. Purchase three-way valves for thermostat-controlled heating in order to accomplish this.
With the same area of the battery, these devices let you control how much water flows through the radiator. Naturally, this means that, within the system’s power limitations, more or less heat will enter the room.
A mixing valve with three settings and a thermostat
Although a temperature controller mounted on a radiator and a three-way valve for the heating system can be used independently, a combination approach is frequently employed to boost efficiency in the self-contained heating systems of contemporary apartments and private cottages.
Purchasing a three-way valve for heating with a thermostat is therefore advised.
It is crucial to remember that the radiator’s temperature can only be raised or lowered within the predetermined range by the three-way mixing valve’s operating principle. These limitations are determined by the thermal device’s technical attributes, specifically the amount of its maximum heat transfer, and are unique to each radiator.
Three -way valves with an electric drive: features and advantages
This kind of device is not appropriate to lower the coolant flow rate because the circulation continues regardless of the rod’s position in the three-way valve. The primary distinction between two-way cranes, regulators, and other devices and the ball three-way crane with an electric drive is this.
You can automate the heating three-way valve’s operation with the help of the electric drive.
The principle of operation of the three -way valve with electric drive
The purpose of this valve is to divide or mix the distribution of flows. By allowing the liquid to follow the bypass route rather than a direct one, the separation valve controls the amount of water. One device is used for the entrance, and two are used for the exit.
Mixing the colder or colder to the cold coherent coolant to the hot coolant is the foundation of the three-way mixing valve’s operation when combined with a thermal tower. The temperature of the heat flux changes as a result, and the degree of this change is determined by the predetermined percentage of the linked jets.
A dividing function can also be carried out by two ports—one for the exit and one for the entrance. These valves can be applied to different types of shots.
Three-way valves are frequently used in the chamber where condensate falls at the start of the firebox of solid fuel boilers. In this instance, the valve assists in momentarily shutting off the cold water supply and the heated liquid’s brief path along the short circuit.
The electric drive-based three-way valve scheme
Three -way valves for warm floor and other use options
There are numerous ways to use these kinds of valves:
Controlling a warm floor with a three-way valve
Valve connection schemes to the heating system
Knowing what a three-way valve is and how it functions will help you think through different connection options based on the element’s use and function in the home’s heating system. There are four situations where a 3-leaf valve installation is done:
- To protect a solid fuel boiler from condensate and temperature shock after sudden power outages.
- The coolant in the circuits of warm floors should warm up to 45 ° C, the temperature supports the mixing node with a three -way crane.
- To maintain the necessary water temperature in different branches of the system.
- When you need to connect an indirect heating boiler to a single -circuit gas boiler.
It is not possible to allow the supply of cooled water from the radiator network while the heat unit on solid fuel is warming up in order to prevent condensate from forming. In order to accomplish this, a boiler with bypass and a three-way mixing valve are connected using the following diagram:
This is how the plan operates. The water makes a tiny circle through the bypass even though the heat generator hasn’t warmed up. The valve starts to open and mix the system’s cold coolant when the coolant heats up to between 50 and 55 °C. The bypass is blocked and the entire stream passes through the radiators when the heater is in the operating mode. See the video for more information on this subject:
This component serves the same purposes in the warm floor system. The coolant is pushed through the warming circuits by the circulation pump until it begins to cool. The three-way valve will then add hot water from the boiler to the closed circuit as soon as this occurs, activating the sensor and thermal head. How to install a warm floor, pump, and valve collector as indicated in the diagram correctly:
The valve keeps the floor’s temperature between 35 and 45 degrees while the pump moves water through the warm floor’s contours.
An example of utilizing and attaching this crucial component is the strapping of a heat generator powered by solid fuel and a heat accumulator buffer capacity. The supplied coolant, which is not required in the radiator heating system, should be between 70 and 85 °C in order to fully warm it. Just reduce it with the assistance of a separate circulation pump and a three-way valve that is mounted behind a container.
Two mixing valves are used in the diagram with a heat accumulator and TT-cat; each one controls the temperature in its contour.
Vital. Keep in mind that the pump should be placed on the side of the three-way crane where there is always an open pipe when installing the mixing valve.
Many consumers can be connected to a large cottage’s complex heating system via a distribution collector and a hydraulic shooting. Furthermore, you must use a different temperature coolant in each contour. There is no regulatory reinforcement on the eyeliner because indirect heating requires the highest boiler. Three-way valves are used to connect the remaining consumers since they require colder coolant.
Since you must cook water at various temperatures, there is a three-way valve in each circuit. The only item directly connected to the comb is the hot water boiler.
You also need a 3-year crane in the diagram with the indirect heating boiler and the single-circuit gas boiler. At the controller’s command (the electric drive is triggered), the element’s job is to switch the coolant flow to the hotel boiler’s coil.
The valve alternates the flow between two lines, so even though the coil is warming the boiler, the heating is not actually occurring.
Choosing a three -way valve: features of models of different companies
It is vital to compare all the features of various models, including the type of executive mechanism, drive type, presence and type of thermoregulator, manufacturer, and cost of a three-way crane for heating, in order to select the right valve. It is worthwhile to consider the models made by top producers.
Three -way valves ESBE: Installation instructions and features
The affordability and ease of use of ESBE models are two of their key benefits.
A three-way valve to warm up ESBE production
Excellent guidance!Simple models have the main disadvantage of not allowing you to stabilize the temperature regime at the output if you need to adjust the crane.
The following features need to be considered when installing the valve:
- The mixing node allows you to create an additional outline in the system connected to the distribution collector with two points, which guarantees continuous circulation of water at the output.
- At the entrance, the flow is ensured in case of need for additional heat.
- The thermostat valve is attached to the mixing unit.
- To increase the consumption of pumping equipment, which is often not enough due to the narrowness of the valves converging at one point, it is required to create an additional line that reduces the electrical consumption of the pump. However, such measures are not relevant for all Esbee models.
- In case of need for the second line, it is planned to install a balancing crane or connect the pump to this additional line, which leads to equalizing the temperature of the input and output flows.
A heating system-integrated ESBE valve
Three -way valves Navien: features and advantages
The manufacturing of heating boilers is the focus of the Navien company. This equipment’s three-way valves are made to switch the order in which the heating system and the water supply get heated. These valves ought to be purchased along with Navien equipment since a single manufacturer’s parts and apparatus are essential to the system’s prolonged and effective operation.
Danfoss three -way valves: features and advantages
Systems for water supply and heating employ Danfoss production valves. The following are some benefits of this kind of equipment:
- stability and accuracy of adjustment;
- ideal compatibility with other thermostatic elements of Danfoss;
- reliability and long service life without loss of operational characteristics;
- simplicity in installation, maintenance and operation;
- entirely automatic work;
- the possibility of installation on the pipeline in any position, except as a valve down.
Three-way Danfoss valve
You can select the ideal device for a particular room and operating conditions after carefully reviewing the technical specifications and recommendations for selecting a three-way valve for heating systems.
The scheme of the valve with the saddle mechanism:
Utilizing a saddle executive mechanism
Overlapping the saddle (5) is the cone (3), fixed on the rod (4).
There are two types of varying valves with different executive mechanisms: dividing and mixing.
A mixing valve (SK) with two entrances for a single exit. The primary use is for heated flooring. Numerous streams arrive at the entrances and combine to bring the temperature down to the desired level.
The situation with the separation valve (RK) is the opposite: one input has two exits. A valve splits the flow of water into two directions.
There are variations in the quantity of balls: one in the UK and two in the Republic of Kazakhstan. On the weekend nozzle, they are constructed. So many ball valves – so many outputs. Arrows indicate the flow of water.
More SK are utilized in heating lines. For DIS, divide. While the quality of the liquid in one separated stream will always be present, the mode in the second stream may fluctuate (only the quantity matters).
You can attain the required temperature in the continuous circuit by adjusting the rod. There is full overlap possible in the alternating circuit.
Areas of application
A three-way valve, whose working principle was previously discussed, has a plethora of applications. Because of this, variations of it, like an electromagnetic device or a device with a thermogram, are frequently seen in contemporary highways, where it is necessary to mix two distinct fluid flows in certain proportions without lowering power or volume.
Thermostatic mixing devices, which allow you to modify the working fluid’s temperature as previously mentioned, are thought to be the most widely used in daily life. This liquid can be used in heating radiators as well as the "warm floor" pipeline. Additionally, if the valve has automatic control, it will be easy to regulate the temperature in the house!
Remark: Not only is it very convenient and comfortable, but it also saves money when a three-way valve is used in the heating system to balance temperature drops.
The truth is that fuel consumption can be greatly decreased by controlling the liquid’s temperature at the heating device’s "return," though this will have an impact on the system’s overall efficacy. The valve is just required in some systems. For instance, the "warm floor" system shields users from discomfort by preventing the floor covering from overheating above a predetermined degree of comfort.
Water supply systems also employ these kinds of regulatory devices to maintain a constant flow at the proper temperature. The most basic example is a regular mixer where the cold crane can be opened or closed to change the water’s temperature.
Safety valve for boilers
In our previous post, we covered the internal device, its areas of use, and how to select and connect a safety valve for a boiler. Apart from reading this piece, we advise you to familiarize yourself with: Here are all the specifics.
Best famous manufacturers and models: characteristics and prices
In order to make it simpler for you to select an appropriate model, I’d like to now discuss the most widely used and dependable three-way valves.
TIM
Chinese manufacturer. provides reasonably priced, high-quality water supply and heating products.
Photo | Model | Specifications | Peculiarities | Cost, rub. |
![]() |
(Zeissler) BL3110C04 | Material: brass Temperature range: 35-60 WORKS ATSENTION: 2-5 bar DIAMETHER: 1 inch |
Mixing, for heating and DIS | 2 300-3 000 |
![]() |
BL8803 | Material: brass Temperature range: 38-60 WORKS ATSENTION: 3-10 bar DIAMETHER: ¾ inch |
Mixing, external connection through American | 2 800-3 500 |
![]() |
BL8804A | Material: brass Temperature range: 38-60 WORKS ATSENTION: 3-10 bar DIAMETHER: 1 inch |
Mixing, electric drive | 2 000-2 600 |
ESBE
This company located in Sweden produces a range of controller and valve models. I think this company produces the best-quality goods. though pricey.
Photo | Model | Specifications | Peculiarities | Cost, rub. |
![]() |
Vta321 | Material: brass Temperature range: 35-60 WORKS ACTION: 2-10 bar DIAMETHER: ¾ inch |
Mixing, for heating and DIS | 6 000-6 500 |
![]() |
Vta372 | Material: brass Temperature range: 20-55 WORKS ATSENTION: 3-10 bar DIAMETHER: 1 inch |
Mixing, high throughput | 7 000-8 000 |
![]() |
VTC511 | Material: cast iron Temperature range: 60-75 WORKS ATSENTION: 3-10 bar DIAMETHER: 1 inch |
For solid fuel boilers | 8 000-9 000 |
Stout
Germany, Italy, Spain, and Russia all produced together. The products fit the Russian environment perfectly.
Photo | Model | Specifications | Peculiarities | Cost, rub. |
![]() |
SVM-0120-164325 | Material: brass Temperature range: 20-43 WORKS ATSENTION: 3-10 bar DIAMETHER: 1 inch |
Mixing, for heating and DIS | 4 500-5 000 |
![]() |
SVM-0125-186520 | Material: brass Temperature range: 30-65 WORKS ATSENTION: 3-10 bar DIAMETHER: ¾ inch |
Mixing, for heating | 4 000-4 300 |
![]() |
SVM-0120-256025 | Material: brass Temperature range: 35-60 WORKS ATSENTION: 3-10 bar DIAMETHER: 1 inch |
Mixing, high throughput | 5 200-5 800 |
Watts
One of Europe’s biggest producers of heating apparatus. an enormous selection of goods.
Photo | Model | Specifications | Peculiarities | Cost, rub. |
![]() |
Aquamix 61c | Material: brass Temperature range: 32-50 WORKS ATSENTION: 3-10 bar DIAMETHER: ¾ inch |
Mixing, for DIS | 5 200-5 700 |
![]() |
Aquamix 63c | Material: brass Temperature range: 25-50 working pressure: 1-10 bar DIAMETHER: ¾ inch |
Mixing, for warm floor | 5 500-6 000 |
![]() |
V3GB Watts Classic | Material: brass Temperature range: 20-50 WORKS ATSENTION: 3-10 bar DIAMETHER: 1 inch |
Mixing, electric drive | 12 500-14,000 |
Installation recommendations
Even though it might seem easy to install the unit in the heating system, there are a few things you should be aware of. You can prevent a lot of issues by carefully reading the instructions before beginning any installation work. This first pertains to the device’s proper placement. Arrows pointing in the coolant’s direction of motion are visible on its case. Install the device following these guidelines.
Furthermore, mounting the device using a thermogol or a drive down is not feasible. You must stop the coolant flow and inspect the pipeline for water residues before beginning the installation. Selecting the installation location is equally crucial since the gadget must be made freely accessible.
Installation of the mixing valve
The method used to connect the heating system determines which of the various installation schemes is selected. It is impossible to prevent the appearance of excess pressure if the heat generator’s operating conditions permit the return to overheat. Installing a jumper to reduce the excessive coolant pressure is required in such a scenario. It is positioned in line with the valve.
The balance valve needs to be installed if the device is directly connected to the heat generator. The most common heating system connection scheme in autonomous heating systems is a three-way crane scheme. It should be kept in mind that it cannot ensure that the heat-growing fluid will not circulate through the source. It is worthwhile to connect a hydraulic delimiter and circulation pump in order to complete the task to its contour.
It is essential to comprehend the functioning of the three-way valve in order to ensure effective insulation and heating in your house. This valve is essential for regulating the flow of hot water through your heating system, which enables you to maximize energy efficiency and control temperature.
A precise plan is followed during the installation of a three-way valve to guarantee optimal operation. It usually has one inlet and two outlets and is positioned in line with the hot water supply. It assists in achieving the ideal temperature in different areas of your home by directing water flow in different directions.
To get the most out of a three-way valve, installation must be done correctly. It should be placed thoughtfully within your heating system, considering things like how far it is from the boiler and how close it is to radiators or underfloor heating components.
A three-way valve can greatly increase the efficiency of your heating system when it is installed properly, which will reduce energy costs and create a cozier living space. Maintaining optimal performance also requires regular monitoring and maintenance.