The main faults and error codes of gas boilers Wismann and recommendations for their maintenance

Gas boilers are vital appliances in many homes because they effectively heat and heat water. Wismann boilers are well-known for their dependability and efficiency among other respected brands on the market. They are susceptible to errors and faults, though, just like any complicated system, which could prevent them from functioning properly. Maintaining a cozy and useful home environment requires an understanding of these flaws and knowing how to fix them.

Error codes are frequently displayed by your Wismann gas boiler when a malfunction occurs, indicating the type of issue. These error codes can indicate anything from straightforward problems like low water pressure to more complicated problems needing expert assistance. Understanding how to decipher these codes can help you avoid further harm to your boiler and save time and money by allowing you to promptly address minor issues.

One common issue with Wismann boilers is that they sometimes have ignition issues. A malfunctioning electrode or a blocked burner are two possible ignition system problems that could be the cause of your boiler’s inability to ignite. Cleaning or replacing the faulty parts can frequently fix ignition problems, but it’s crucial to seek advice from a qualified technician or the manufacturer’s handbook.

A common problem is a decrease in boiler pressure, which can result in less effective heating and even system damage. Error codes on the boiler display frequently indicate low pressure, which can be brought on by system leaks, bleeding radiators, or a malfunctioning pressure relief valve. These problems can be avoided by routinely checking and maintaining the boiler’s pressure within the advised range.

Regular maintenance is crucial for maintaining the best possible performance and longevity of your Wismann gas boiler, in addition to fixing specific issues. This entails performing maintenance on the heat exchanger, examining and changing worn-out parts, and looking for leaks in the system. It is possible to reduce the likelihood of unplanned malfunctions and prolong the life of your boiler by adhering to a thorough maintenance schedule.

Main errors and malfunctions

In the event of an operational issue, the Wiesmann boiler has the capacity to produce a sizable number of errors.

Error code 06

Alerts the user that the system’s burner is blocked. The water heat exchanger’s inadequate pressure buildup is the cause of the issue. The diaphragm drum’s working pressure must be maintained in order to stop this code from appearing. It shouldn’t be less than 0.8 bar at the inlet. It is sufficient to bleed extra air from the radiators and top off the heating medium volume using the make-up tap in order to fix the failure.

The lower section of the boiler’s front side is where the make-up valve is situated in Viesmann gas boilers.

Error code 0A

In addition to being blocked, the burner will malfunction. An indicator of the dynamic pressure of the incoming gas is too low, which is the root cause of the violation. For the system to continue operating without interruption, a dynamic pressure norm of 8–25 mbar is acceptable.

Wisman boiler error codes

Using a gas pressure gauge to check system pressure is necessary for troubleshooting. To increase the pressure if the gas is not flowing with enough force, give the gas service company a call. If the gas moves with normal force, the pressure control switch isn’t working properly. In this instance, only a service center can assist.

Error code 0C

Additionally, the burner is instantly blocked. The low voltage of the network that the boiler is connected to is the cause. This typically occurs when multiple powerful appliances are simultaneously connected to the power grid. When one of them is disconnected, the voltage will return to a sufficient level. To eliminate concerns about potential issues with the boiler’s power supply, a stabilizer installation is sufficient.

Insufficient voltage levels in the network are frequently caused by the owner themselves. Select cables with enough cross-section to supply the system when installing the cable.

Error code CC

This infraction indicates that the external expansion module is malfunctioning. Restoring communication between the boiler controller and the module is required to remedy the situation. Checking that the cable is connected to these two system components is usually sufficient because occasionally they come loose. A complete cable replacement will be necessary if the wires are damaged.

Error code F02

When the burner malfunctions, the infraction appears. Once the error code appears, the coolant level in the system needs to be checked. Excess air is vented when necessary; otherwise, it typically condenses in circulation pumps or radiators. It will be necessary to examine the temperature limiter’s operability if these adjustments prove ineffective.

In order to accomplish this, the following manipulations must be performed:

  • Disconnect all cables connected to the sensor;
  • check if the current is flowing through the limiter;
  • if the limiter is not faulty, it should be removed;
  • after dismantling, the place of the element is lubricated with heat-conducting paste;
  • A new temperature limiter is installed;
  • To unlock the element in the system, it is required to dial the mode and ok buttons in turn;
  • reignite the boiler.

It is necessary to determine whether or not the gas burner automatic unit is blocked if adjusting and checking the temperature limiter does not resolve the issue. It is best to get in touch with a service center if it breaks down.

This error code occasionally appears when there is damage to the connecting cable. Until the elements’ connection is fully restored, the issue won’t be resolved.

Error code F03

The flame start signal appears prior to the burner starting when this issue occurs. Usually, this code means that the ionized electrode needs to be fixed. In rare circumstances, it will be sufficient to restart the system, reset it, and make sure all of the contacts are connected. However, a more significant repair is usually needed.

We’ll dissect the typical problems and error codes unique to Wismann boilers in our guide to gas boiler maintenance, providing useful advice for homeowners. Whether the issue is related to pressure, ignition, or a sensor error, knowing these codes can prevent expensive repairs and guarantee that your house is kept warm effectively. We’ll give you step-by-step maintenance guidelines and troubleshooting advice to keep your Wismann boiler operating efficiently all year long. With these insights, you’ll be more prepared to maximize energy efficiency, maintain a comfortable living space, and respond to issues quickly.

Error code F04

The system does not receive a flame start signal in this instance. Restarting the entire system usually solves the issue. The ionized electrode and ignition electrodes need to be inspected for damage if this doesn’t work. It will be essential to get in touch with a service center if they are mechanically damaged.

Additionally, the integrity of the ignition module and the gas supply pressure must be checked when this error code appears.

Error code F05

The combustion apparatus is the source of the issue. The air supply relay cannot open after the burner has been started. The "Air and combustion products" system holds the key to solving the issue.

These tricks will assist in solving the issue.

Error code F08

Appears when there is blockage in the solenoid valve. The burner is also entirely blocked as a result of this error. To remedy the situation, make sure the valve, relay, and connecting wires are in good working order.

The solenoid valve is the one that requires careful inspection:

  • A new thermocouple must be installed first;
  • After that, a soldering iron is lit and brought to it;
  • If the automatic system is triggered after the combustion signal, the valve is faulty.

In this instance, if the relay is the issue, you will need to check the cables or get in touch with the service.

Error code F10

The boiler will continue to function normally in the event that this fault materializes, but it is probable that new room or outdoor temperature sensors will be required. When the sensors in the gas boiler short circuit, a signal is sent out. Repair is necessary if the devices’ allowable values deviate from one another.

Error code F18

Occurs when there is a loss of communication between the room temperature sensor and the outdoor sensor. It only needs to be repositioned if it is lost due to a disconnected terminal. Should the cable break, a full replacement is required.

Error code F30

It indicates that the boiler temperature sensor has shorted circuit. Check it right away for damage and to make sure all of the cables are attached. It will be necessary to check the resistance if everything appears normal from the outside. Disconnect the cable and check the resistance values to accomplish this. Should they fail to meet the manufacturer’s specifications, the sensor will require replacement.

Error code F38

Appears when the boiler temperature sensor is not in communication. Restoring communication requires either swapping out the damaged cable or reinstalling it. The sensor needs to be changed if this is ineffective.

Error code F51

The boiler’s inability to heat the water is the root of the issue. The sensor that gauges the temperature of the water at the outlet shorts, resulting in the violation. It is essential to verify the element’s operability before replacing it. Disconnect the cables and measure the resistance to accomplish this. If it is not normal, it needs to be repaired.

The capacitive water heater’s sensor resistance is also measured in case this issue arises. Disconnecting the plug from the controller’s cable harness is required prior to performing diagnostics.

Error code F59

Occurs when the temperature sensors for the tank water heater and the water are both open. Verify the plug’s continuity and replace it if needed. If it’s just disconnected, all you have to do is carefully reinstall it.

Error code F70

Alerts the external module to a problem. appears solely as a result of a short circuit in the external module-connected collector temperature sensor S1. To get the system working again, the sensor must be completely replaced.

Error code F78

It is necessary to verify that the collector temperature sensor S1 and the external module are communicating. The cable needs to be pulled more tightly if it is unplugged. It is easily replaced if it is damaged. There is nothing more to fix.

Error code F80

The external module is also connected to the issue. appears only when the temperature sensor in the collector S2 is shorted. It is essential to replace the element with a new one after determining the resistance level.

Error code F88

Appears only when the tank water heater’s bottom S2 sensor is not sending out an electrical signal. It is linked to the external module directly. It might be required to swap out the sensor or the cable connecting it to the external module entirely in order to resolve the issue.

To be certain the sensor is broken, always take a pre-measure of its pressure. If it is typical, another source of the issue needs to be investigated.

Error code F90

The external module is involved in this violation. appears when the tank water heater’s upper sensor S3 has a short circuit. If necessary, diagnostics are performed before the element is fixed or replaced.

Error code F98

Appears only in the absence of an electrical signal from the cylinder heater’s upper sensor S3. Like other components of this kind, it is also linked to an external module. Either the sensor or the cable connecting it to the external module needs to be completely replaced in order to fix the issue. In certain cases, inserting the cable into its terminal suffices.

Main Faults and Error Codes Recommendations for Maintenance
1. No Heat Check if the gas supply is on. Reset the boiler and monitor for error codes.
2. Low Pressure Refill the system with water to the recommended pressure level. Check for leaks.
3. Ignition Failure Clean the ignition components and ensure proper fuel supply.
4. Flame Failure Inspect and clean the burner assembly. Check for obstructions in the flue.
5. Overheating Check the thermostat settings and ensure proper ventilation around the boiler.

Our homes require gas boilers to be heated effectively and consistently. They are susceptible to malfunctions and mistakes, though, just like any mechanical system, which could cause them to stop working. To guarantee the longevity and efficiency of their heating systems, homeowners must be aware of these frequent problems, particularly with Wismann gas boilers.

Error codes are among the most frequent issues that arise with Wismann gas boilers. These codes, which identify particular system problems, are shown on the boiler’s control panel. Every error code indicates a possible issue that needs to be fixed, from ignition problems to sensor malfunctions. Ignoring these codes or not addressing them right away may cause more serious problems later on, which may require expensive repairs or possibly a new boiler.

Wismann gas boilers require routine maintenance in order to avoid and lessen these problems. This includes arranging for yearly boiler maintenance by a licensed specialist who can examine the boiler, clean its parts, and make sure everything is operating as it should. In addition, homeowners can prevent problems with their boilers by keeping them clear of debris, inspecting them for leaks or strange noises, and routinely checking on their performance.

Moreover, homeowners can self-diagnose minor problems by learning the specific defects and error codes linked to Wismann gas boilers. Common problems can frequently be fixed without the need for professional assistance by performing simple tasks like resetting the boiler, inspecting for blocked pipes or vents, and making sure there is adequate ventilation. But it’s important to use caution and, if in doubt, seek advice from a technician or the boiler’s handbook.

In conclusion, despite their reputation for dependability and efficiency, Wismann gas boilers are not impervious to issues and mistakes. Through education about typical problems and error codes, homeowners can prevent problems with their boilers and guarantee continuous heating during the winter. To ensure that Wismann gas boilers last as long as possible and give homeowners comfort and peace of mind, regular servicing, timely attention to error codes, and proactive maintenance are essential.

Video on the topic

Viessmann (Viessmann) boiler error F05 how to do

Boiler output setting #viessmannVitopend100

Viessmann vitoped 100 boiler,reset error F2 and F4

Viessmann boiler error f4. How to reset the boiler via the REZET function

Viessmann Vitopend 100 Opentherm On activation

F2 error on gas boiler. MASTER CALL? Gas boiler repair

Viessmann Vitopend service and overview

Gas Boiler Board Repair. Everything the owner needs to know not to get caught out.

What type of heating you would like to have in your home?
Share to friends
Sergey Ivanov

I like to help people create comfort and comfort in their homes. I share my experience and knowledge in articles so that you can make the right choice of a heating and insulation system for your home.

Rate author
vDomTeplo.com
Add a comment