Malfunctions of gas columns – a description of breakdowns, calling the master

Many homes depend on gas columns as necessary appliances to provide hot water for cooking and bathing. But just like any other appliance, gas columns can break down or malfunction. These malfunctions can be anything from little troubles to major issues that need a professional’s quick attention. In this post, we’ll go over typical gas column problems, how to spot them, and when to get in touch with an expert.

Absence of hot water is among the most frequent problems with gas columns. A malfunction may be indicated if your gas column stops producing hot water or if the temperature of the water changes suddenly. Many problems, such as a broken thermostat, a broken gas valve, or a problem with the pilot light, could be the source of this. While the homeowner may be able to resolve some of these problems on their own, others might call for professional assistance.

A peculiar smell emanating from the gas column is another frequent issue. It’s critical to take immediate action if your gas column begins to smell strongly of gas. Gas leaks should be fixed right away because they can be very dangerous. You might detect additional indications of a gas leak, such as sounds coming from the appliance, like whistling or hissing, in addition to the gas smell. It’s critical to turn off the gas supply to the appliance and get in touch with a professional straight away if you suspect a gas leak.

Sometimes, you might hear odd noises coming from your gas column while it’s working. These sounds can be anything from soft knocks or rattling to loud, frightening noises. While some noise is to be expected from gas columns, particularly from older models, excessive or unusual noises may indicate a problem. Unusual noises in gas columns can be caused by a malfunctioning burner, sediment accumulation in the tank, or issues with the gas line. It’s best to have a professional inspect your gas column if you hear strange noises coming from it in order to identify the source.

It’s critical to take immediate action to fix any of these typical gas column problems in order to stop additional damage and guarantee the security of your family and house. Even though a homeowner may be able to fix some small problems, it’s always advisable to err on the side of caution and seek professional assistance. A skilled specialist will be able to identify the issue and swiftly and safely complete any required repairs to get your gas column operating properly again. Make sure your home is operating safely and smoothly by calling a professional as soon as you notice any indications of gas column trouble.

Gas column malfunction Calling the master
No hot water Contact a certified technician immediately
Strange odors Turn off the gas, open windows, and call a professional
Water leaks Shut off the gas, water, and call for professional help

Reasons for the lack of flame on the wick of a gas column

  1. The air supply hole into the wick is clogged. Air is carried out through this hole to ensure the combustion of natural gas on the tip of the fabric.
  2. The coil of the electromagnetic valve burned. The electric magnet holds the valve rod, after its breakdown, the valve will be closed.
  3. The thermocouple. The thermocouple, while in flames, produces the voltage supplied to the electromagnet.
  4. The sensors of monitoring the temperature of the water and the state of the chimney (the presence of traction) are faulty. With a value of up to + 82 0C, the sensor is in a closed position, from above this temperature, its bimetallic plates diverge and the chain opens. Violate normal contact between the two plates can oxidize the surface, mechanical or thermal damage.
  5. The electrical circuit of the flame control system is impaired. All the elements of the flame control system are interconnected by wires. Their malfunction will inevitably lead to a violation of the entire system.
  6. A nozzle or a gas supply tube into a wick is clogged. The internal diameter of the tube is 2.5 mm (external 4 mm) diameter of the outlet of the nozzle 0.1 mm. These elements can clog with soot, dust, etc. D.
  7. The work of Piezoelent, from the sparks of which the gas ignition is broken, is disturbed.

Fast prevention

Device occasionally needs to have a preventive inspection

Finally, a few words about basic operating guidelines that should help you steer clear of the majority of malfunctions. Which operating guidelines then need to be followed:

  • Ensure a sufficient amount of air, with insufficient oxygen intake, the column does not work. Open windows and windows during the operation of the unit;
  • Do not turn on cold water with hot. If the water that is supplied with a column is too hot, then it is better to adjust the water temperature than to dilute it with cold.
  • Carry out periodic examinations, prevention, this will help to timely identify problems and quickly repair them;
  • Do not install flexible hoses with a length of more than three meters, this can significantly reduce the pressure of the gas supply, which will lead to interruptions in the operation of the column.

Keep in mind that handling gas devices responsibly is necessary. It is extremely important to consult a specialist if you lack confidence in your abilities, as this can have disastrous outcomes.

Liquidation of the problem

Transient. You can open the window to let the room’s temperature drop. The water heater will not shut off at the same moment because of a drop in temperature, which will prevent the relay from overheating and prevent it from turning on.

Finally. The only way to fully resolve the issue is to swap out the faulty relay.

There is an ignition system flaw.

Scent burners are one kind of gas column that is available. However, more recent models come with an electronic ignition system as standard. There are two ways to generate a spark: using nutrition elements (batteries); or using a piezoelectric element that is activated by a turbine-like device inserted into a water system.

Hot water heater

Maybe the batteries just need to be changed if using them to generate sparks is the option. Experience has shown that, despite manufacturers’ claims that power elements will function dependably for a long time, replacement is required roughly annually.

Low or nonexistent cold water pressure.

Enough pressure must be present in the cold water entering the system to initiate a gas column. The oasis’s heater will just shut off when the cold water pressure drops. As in the event of the crane closing, the protection will cut off the column and cause it to go out. In this instance, you ought to identify the root of the issue. Any cold water crane can be opened.

  1. If the water pressure is weak and there, then you will not be able to do anything, since such a pressure comes from the city system.
  2. If the water from the tap comes normally, then, probably, cleaning or replacement of the filter is required. If the problem is not in the filter, then you have to clean the radiator of the gas column.

The steps involved are as follows:

  • Overlap the gas supply valve;
  • Unscrew the pipes;
  • Remove the water heater from the loops;
  • We turn upside down and, in this position, place on the table;
  • Pre -purchased fluid in a specialized store for flushing is drained into the syringe and insert into the column;
  • We leave in this state for two to three hours;
  • After that, drain the liquid, rinse with water and mount in the reverse sequence.

Certain models come with a unique pen that controls how much water flows through. Should the tap’s water pressure be sufficient to initiate the column, the handle should be shifted to the far left and then to the right until the water heater activates. Typically, the duct needs to be adjusted once during the launch.

A malfunctioning membrane is one of the reasons the gas column is not lighting up. The column can no longer function normally if it has mechanical damage or has lost its elasticity.

This malfunction falls into the more complicated category. The membrane must be disassembled by keeping track of each part’s location in order to identify the cause of the malfunction. In order to accomplish this, you must take the water unit out of the water heater. After disassembling it, you can remove the membrane. Silicone membranes are worth the extra money because they last longer than other types of membranes.

The column does not ignite

Think about the causes that led up to this issue.

Absence of momentum. Generally speaking, a malfunction happens when an extraneous object gets into the exhaust channel and stops the system’s air flow from operating as it should. The accumulation of numerous combustion products is the second factor contributing to the problem’s formation. Consequently, a protective machine starts operating automatically.

To check the thrust in the ventilation system, a match must be brought in. In the event that it is available, the flame will flow in the channel’s direction; otherwise, the fire does not flush.

Since some soot settles directly on the column’s surface in the second scenario, it’s critical to vacuum the column and clean the channel as soon as possible. The room where the gas water heater is installed must be periodically ventilated in order for the device to operate continuously. This is because the system may only operate briefly in the absence of oxygen, which increases the risk of gas poisoning.

  • Old batteries. One of the most common reasons why the water heater is not turned on is the end of the service life of the power elements. To eliminate the problem, it is enough to replace the batteries in the device.
  • Faint pressure of cold water. In this case, you need to call the technical support service and leave a request. As a rule, within 3-4 hours, an authorized person will come to identify the cause of the malfunction.
  • Fearing the shower. There are times when hot water after switching from a crane to shower disappears sharply, as a result, the column quickly goes out. To eliminate the problem, it is worth examining the aerator, as well as a flexible hose, followed by its cleaning if necessary.

Recall that when the litter is operating properly, its flame is bluish in color and ignites evenly and on schedule. Should an orange hue be observed, it is imperative to cleanse the nozzle—the gas supply tube.

Lights up, but rotten

Think about the following situations when the column fades after ignition and possible solutions:

One of the causes is the device’s inadequate thrust, which results from the absence of airflow inside.

Verifying the traction power

When the doors and windows are securely shut, this occurs. As a result, the overheating sensor triggers a protective relay overheats.

By opening a window or windows and letting a draft enter the space, you can get rid of it. The gas heater needs a steady supply of fresh air to operate because it burns a lot of oxygen when it is operating.

A lack of time to hold the ignition button could be the second cause of the column’s attenuation. It must be held for a minimum of 20 seconds; otherwise, the column will disappear.

The next instant is when the combustion product removal sensor fails. It must be called in and two terminals connected in order to inspect the sensor. The resistance should typically display infinity. It will be necessary to replace the sensor if the indication changes.

High cold water pressure and hot low temperatures are common causes of the water heater’s stinginess. This occurs when you open the tap with cold water while using hot water. You must set up the water supply so that you can dilute hot water without opening the cold one in order to solve this kind of issue. Additionally, the heater may malfunction as a result of this improper device operation.

The water pressure may rise as a result of the attenuation. This particular issue is unique to the Lux Eco model device, which is made to function at low pressure. Here, the water node’s membrane is bent by the high duct pressure, which also causes the gas supply rod to move. Setting the gas supply or, if it’s feasible, modifying the water pressure is necessary.

This prevents the device from overheating because the temperature sensor is functional.

The column vector’s temperature sensor

After you turn on the heater, he fades once more for a while. The device won’t turn on if you try to turn it on right away. The burner lights up for about twenty-five minutes, but it soon goes out again. An overly sensitive sensor is the issue. Only its replacement will be helpful in this situation.

Thermocouple and electromagnetic valve have poor contact.

The automation unit and its contacts need to be cleaned if the thermocouple is operational.

The fractional itself is designed to produce an electric spark. The comb is welded to the edge of the gas burner approximately 12 mm away from its output, and the electrode is positioned so that the spark lands on it. The gas exits the burner with a small volume and slow speed, assuming that the gas supply has been set to low water pressure.

Because a tiny reverse traction almost always forms inside the system, the pressure of this traction causes a weak gas level to drop, but it never reaches the spark. This can be fixed by bending the electrode away from the comb until the spark passes through the gas precisely in the burner’s center rather than the comb. Almost always, after such adjustments are made, the ignition is quick, steady, and gentle.

The development of holes between the individual sections of the gas outlet, the annexing pipes of the gas outlet and the chimney, and the gas outlet tube. It is identified visually, and in order to remove it, gaps must be sealed with heat-resistant self-adhesive tape or other materials.

Problem: The heat exchanger was clogged

The most frequent cause of gas column malfunctions is clogging in one of the heat exchanger’s (radiator) caps. The overgrowth of tubes is the result of water. When the water temperature reaches above 80 degrees, the deposition of scale starts, and this process intensifies at 82 degrees.

Avoid using water that is too hot to avoid the buildup of scale. The water temperature is just right for swimming at 42 degrees, for removing fat from dishes at 45 degrees (since products that do this can handle cold water), and for washing in an automatic machine at 60 degrees or less.

Because it’s convenient and eliminates the need to constantly incite and configure the column, many people leave a gas column to operate on the faint. Nonetheless, the heat exchanger has enough hours to reach a temperature of 90 degrees, which is why the scale exists. As a result, don’t be lazy and turn the column on and off as needed. You should also avoid redoing the heater automation; instead, use a magnifying pump if your pressure is low.

In that case, you must clean the heat exchanger in order to repair the Chinese gas column.

To accomplish this, you must recognize that the heat exchanger is in fact clogged by keeping an eye out for the following symptoms: low pressure in the hot water tap while there is adequate pressure in the cold water tap; When used in conjunction with this, the column either never turns on at all or turns on and off right away. Naturally, it’s possible that the crane at the gas column’s entrance is broken, but if it’s in working order, move on to dismantling the column.

You will need a rubber hose, a set of paranite gaskets, a set of core keys, and a cross-shaped, flat screwdriver to rinse the column. Furthermore, anti-Nakipine (available in a plastic bottle and as a dry powder) must be purchased in advance by the household. Since vinegar essence is the least expensive, you can also use it.

Remove the casing from the column after removing the fittings. Subsequently, the water supply at the entrance must be blocked and opened closer to the column of any hot water tap. After that, remove the heat exchanger’s supply tube by unscrewing it and set it aside. Water will start to exit the heat exchanger after the nut has been unscrewed. It needs to be nearly completely empty.

After that, attach the hose to the heat exchanger’s input, raise it so that it is higher than the speakers, put the funnel inside the hose, and then slowly pour the prepared solution into it. Leyite gradually; otherwise, anti-Nakipin sentiment will surface and push back. It is recommended that the solution remain in the heat exchanger for a few hours. Furthermore, the material can be heated on a burning carrier to shorten the reaction’s duration.

Replace the basin or plastic bucket beneath the crane, then gradually open the gas column’s water supply. Watch what emerges from the hose. The process will need to be repeated if there is a lot of sludge and the pressure improves after washing. If not, everything went wrong. But you won’t need this if you use anti-Nakipin.

Her error codes in a gas column

An explanation of error causes and correction techniques

Inadequate water heating. Reasons: high water pressure and nozzle contamination in the burning apparatus.

The burning apparatus is not supplied with any gas. Reason: either a cervical system failure or a closed crane.

There is no incendiary flame. The automation provides a spark, but if there isn’t a flame, it signals to shut down.

No flame, no obstruction in the chimney. Reason: malfunctions caused by inadequate air circulation.

Turning down automation. Even though the water pressure sensor is not signaling, electromagnetic valves are activated.

Including a gas burner too soon. The duct sensor is inoperative, but the ionization sensor detects the presence of flame and sends out a signal.

The water pressure sensor does not provide a signal. Rusting the chain connecting the gearbox and electronic unit is the cause.

A water knot fell. A ruptured membrane necessitates the replacement of the gasket. Other indications of a malfunction include the appearance of condensate and leakage from a water unit.

An ineffective attempt to light. A spark is present. The column is turned off once the main burner has been filled. Reason: inadequate or low gas pressure.

Nothing to grip. The detector for smoke gases is activated. The column works for two to five minutes before turning off and on again after cooling.

The sensor for overheating water is activated. There are multiple causes. from the oxidation of contacts to inadequate pipeline pressure.

Although gas water heaters are necessary for our homes to have hot water, they can be dangerous and inconvenient when they malfunction. It’s essential to recognize the warning signs of gas water heater malfunctions and know when to contact a qualified technician to ensure the safety and effectiveness of your heating system. Early detection of common problems such as leaks, strange noises, and pilot light issues can help prevent further damage and guarantee that your gas water heater is repaired safely and quickly.

Malfunctions of gas water heaters

The device meant to heat water works on the basis of the fluid passing through the heat exchanger. In turn, the latter is displayed as a copper tube with ribs. The gas heating pad is used to raise the temperature of the water through operation.

You can automatically regulate the water’s temperature and pressure as well as the gas supply’s intensity because of the installed protection system.

To keep the family budget as low as possible, replacing worn parts on your own will be far less expensive than purchasing a new gadget or hiring a professional to come to your house.

But keep in mind that you should thoroughly familiarize yourself with the water heater’s design, determine the reason for the malfunction, research the technology to fix it, gather the required supplies and tools, and only then start the repair process.

Unfortunately, the "ideal" gas installation model has not yet been created by manufacturers. Because of this, there are a number of well-known drawbacks to every type of water heater that manifest themselves when the appliance is in use.

Think about the device’s primary breakdown and the causes behind their emergence.

  • Scrap in the heat exchanger. It is not difficult to recognize this breakdown, since it has the following characteristic features: when turned on, the device works only a few seconds or there is no reaction to the command of the control system, while the water pressure in cold, hot cranes is the minimum.
  • Leak in the radiator. As a rule, a sign of this problem is the impossibility of obtaining water, the desired temperature.
  • The water heater does not warm the water well. This is due to the fact that the gas supply, the throughput of the liquid is not adjusted.
  • The burner does not light up. This problem can arise for the following reasons: lack of traction, old batteries, weak pressure of water, clogging of the shower.

Furthermore, the lifespan of the gadget is directly impacted by the quality of natural gas and tap water.

Let’s take a closer look at the techniques for fixing these issues.

The gas column does not ignite

The most frequent cause of the gas column not igniting could be the ventilation well’s lack of traction. It is plausible that the chimney either became obscured by soot over time or an unrelated object fell into it. Under these circumstances, the column’s internal protection system trips, automatically stopping the gas flow within the apparatus.

Diagram for installing a gas column.

Examine the chimney’s traction. It’s very easy to do this: bring the lit match to the well; if the flames move toward him, there’s a craving and everything is OK.

Once the root cause is removed, the gas column will function consistently once more. You can either call the masters directly or clear the well.

In this instance, a straightforward power element discharge could also be the cause of the gas columns’ malfunction; however, this is only applicable to devices that have automatic ignition (from batteries or generators). Battery manufacturers guarantee that their products will last a year, but in reality, batteries need to be changed far more frequently.

  • Check the support and off keys for the gas column;
  • Replace the batteries.

Thirdly, low water pressure is not the only reason the gas column isn’t lit. It’s simple to check; all you have to do is open the cold water crane. If there is little pressure, it’s likely that the water supply or its separate location, not the column, is the cause.

If the pressure in the cold water tap is higher than that of the hot tap, the gas column’s water node may be the cause (the membrane may have been distorted or the filters may be clogged). The additional rough cleaning filters that are installed are frequently the cause.

Diagram of a gas column device.

  • First you need to call the communal service in order to find out the cause of the absence of pressure;
  • Rinse cleaning filters or replace it in the mixer;
  • In the communal service, you can leave an application for cleaning pipes supplied hot water;
  • washing the gas column from soot and from combustion products;
  • Replace the membrane of the water node of the column.

Fourthly, it frequently occurs when a gas column ignites and extinguishes right away. It is necessary to modify the water supply in this situation (cold and hot).

Be careful: diluting hot water with cold water is never a good idea as it will instantly put out the flame and is against the column’s operating guidelines. Removing a malfunction requires lowering the amount of water that comes from the cold tap.

Removing a malfunction requires lowering the amount of water that comes from the cold tap.

The water membrane’s deterioration could be another factor in the burner’s inability to function. The burner loses sensitivity and stops working when water is supplied because the membrane from continuous loads becomes deformed over time. There is nothing you can do about it, not even in the columns of reputable foreign manufacturers who recommend changing the membrane every five to seven years.

Turn on the water supply to its fullest. If the column operates at maximum pressure, the issue is likely with the membrane itself, necessitating replacement.

Problem: the gas column does not ignite

1. The absence of traction in the ventilation channel may be the primary cause of the flame’s extinguishment following the gas column’s ignition. The protection system and gas in the device in the water heater automatically block if an extraneous object enters the chimney or if it is packed with a combustion column. It’s easy to check if your chimney has a thrust: hold an open window and press your palm or a lit match against the chimney hole. If you have good traction, you will either feel a breath or see a significant deviation in the flame.

– The ventilation duct needs to be cleaned. Call the management company, leave a request, and make a call to chimney sweepers to accomplish this.

2. The supply elements’ discharge could be the next cause of the absence of flame in the column. This just holds true for speakers that use power elements (generators or batteries) for automatic ignition. Although manufacturers may try to convince you that the batteries need to be changed at least once a year, actual usage indicates that the lifespan is actually shorter.

Verify the column’s on/off key;

– Purchase and replace batteries.

3. The water’s low pressure could prevent the column from igniting. By opening the cold water crane, you can determine the cause. If the cold water’s pressure is the same as that of a hot water tap, the entire water supply is to blame.

If the pressure from a cold water tap is significantly higher than that from a hot water tap, the column’s water node is the source. Most likely, the membrane was distorted or the filters are clogged at the water node’s inlet. Hot water pipes can become clogged. Deep water filtration filters installed in the system may also be the cause of the low water pressure.

– make a call to the communal service to determine the cause of the low water pressure;

– Change the filter in the mixer or rinse the water purification filters;

– submit a request for the communal service to clean the hot water pipes;

– Clear the column of all combustion products and soot;

– Change the membrane at the column’s water node.

4. Occasionally, the column ignites and extinguishes instantly. The hot and cold water supplies in this situation need to be changed. It is not required to dilute hot water with cold; doing so will cause the gas device to operate incorrectly in addition to extracting the column’s flame.

– turn down the cold water flow from the faucet.

Weak pressure of water at the output

Diagram of a gas column chimney.

The block of the heat exchanger capture is the source of the issue if the gas supply happens and the water pressure in the water intake device is normal. The fabric’s prolonged inactive burning may be one of the causes. The heat exchanger is heated by the smell man, which intensifies the evaporation of water residues. Because there isn’t enough water flowing through it, the accumulated scale stays in place until the column is turned on again. Consequently, the column is not functional.

Hard water can cause filling pipes to become blocked. Scrap deposit happens when the water temperature rises above 80 °C, and this process intensifies at 82 °C. You should not use extremely hot water to prevent an increase in scale. The heat exchanger needs to be cleaned or replaced as part of the repair.

If one has the necessary abilities, one can flush the heat exchanger on their own. This calls for:

Diagram of a gas column device.

  • set of rye keys;
  • cross -shaped and flat screwdriver;
  • rubber hose;
  • set of paronite gaskets;
  • antinakipine or vinegar essence;
  • basin or plastic bucket.

Remove the casing from the column after removing the fittings. Next, shut off the water supply at the entrance and turn on any hot water taps that are closer to the column. After that, remove the heat exchanger’s supply tube by unscrewing it and set it aside. Water will emerge from the heat exchanger after the nut has been unscrewed. Has to be emptied close to a liter.

Next, attach the hose to the heat exchanger’s input, raise it slightly above the column, fit the funnel into the hose, and then slowly pour the prepared solution into it. Pouring slowly is necessary to prevent the anti-Nakipin from pushing back. It is necessary to leave the solution in the heat exchanger for a few hours. The substance can be heated on a burning faint to speed up the reaction and reduce its duration.

Replace the water supply to the gas column with a plastic bucket or basin, and gradually open the water supply.

Be mindful that it will come out of the hose. Everything worked out if there was a lot of sludge and the pressure after washing improved; if not, the process had to be repeated.

This is not necessary when taking antinakipine.

The main malfunctions

Regardless of the model you have installed, malfunctions in its operation will eventually surface. The following issues are not disregarded:

  1. The device simply does not ignite. In this case, there may be clicks.
  2. The device starts, but it goes out during the work.
  3. When the column works, powerful claps are heard.
  4. No water heating.
  5. There are leaks.
  6. During the operation of the unit, the smell of Gary appears.

You can attempt to handle issues on your own. However, you will need to have good experience in this field and a tolerance for gas-powered equipment.

It makes more sense to apply for repairs and get in touch with the local gas service.

You can get in touch with the service department of the store where you bought the equipment if it’s still under warranty. Repairs ought to be done without charge.

You will have to pay for services if the warranty has expired. The price tags seem to be in different places. Everything is dependent upon the nature of the breakdown and the intricacy of the task.

In cases where the device is fatal, it must be replaced.

Typical problems

The following scenarios are the most frequent ones that gas water heater owners deal with.

The heat exchanger clogged

Over time, a scale develops in the heat exchanger as a result of either excessively high water temperature or excessive water stiffness. This means that this part needs to be regularly cleaned using a method that removes the scale (at home, the most common method is to use a lemon-k-you solution). A blockage in the heat exchanger may be indicated if you observe that the pressure of the warm water is low while the water pressure is high. Additionally, after a brief work, the column might not turn on or disconnect if there is too much scale.

Watch the brief video below to learn another method of cleaning the heat exchanger.

Water does not heat up to the desired temperature

After identifying this issue, you should first confirm that the device’s power settings are correct. If all the settings are correct, the cause of the inadequate water heating could be either too low of an incoming water temperature (which is normal for the winter) or contamination of the heat exchanger (both internal from scale buildup and outside from soot).

The column does not ignite.

The most common cause of this situation is insufficient ventilation, which can consist in pollution of the ventilation well (the soot accumulates in the chimney over time, and an extraneous object may also get), and in the absence of a sufficient air flow into the room (for example, after replacing windows). For devices operating on batteries, a situation where the device does not turn on at all, is usually associated with complete discharge of power elements. In addition, the equipment will not be turned on if the water pressure is too weak (this also applies to the pressure of the gas), the membrane was damaged or gas leaks occurred. In these cases, the system will prevent the system for protecting the device.

The membrane in the column’s water block can be independently replaced with the aid of the ensuing video tutorial.

The burner of the device goes out during operation

Poor traction, a malfunctioning electric valve, a problem with the temperature sensor, or wear on the water node’s membrane can all contribute to this kind of issue.

The flow from the heat exchanger

This issue is typical of low-quality details where copper is associated with various contaminants. The heat exchanger’s surface oxidizes in areas where there are impurities, and fistulas eventually form there. Replacing the heat exchanger will be a drastic solution to this issue, but if the damage is not too great, the part can often be sealed with a soldering iron or a gas burner. See our article "How to Pull a Gas Column?" for instructions on how to do it yourself.

The problem with the blockages

Filters that remove tiny solid contaminants from water are frequently positioned at the gas column’s entrance. This is where soils settle and become a barrier to normal, fluid passage. Consequently, the column stops igniting and provides the family with hot water. In this instance, you must unscrew the filter, shut off the water supply, and clean the device. It is simpler to replace the filter if its condition is extremely challenging.

Put the heat exchanger in a water-and-detergent solution to clean it, then fill the tubes to the brim with citric acid and let it sit for 30 minutes.

Additionally, over time, the columns within it may clog heat exchangers or tubes. In this instance, you must ensure that the heat exchanger is cross-country and verify the patency of the water node. Blocks are removed by washing with specific reagents; to purchase them, get in touch with your neighborhood home improvement store. Your gas column’s performance will be restored after cleaning.

Install a good filter at the column’s entrance to keep the interior from becoming clogged with sediments. This will soften hard water and remove small impurities.

For your home’s comfort and safety, it is essential that your gas column functions properly. But just like any other appliance, gas columns can break down. It’s critical to identify these issues early on and contact a trained specialist to stop additional harm and guarantee your family’s safety.

It’s crucial to pay attention to any malfunction indicators you come across, such as strange noises, erratic heating, or a drop in the amount of hot water available. Maintaining the use of a malfunctioning gas column can result in major safety hazards as well as more involved and expensive repairs down the road.

If you experience any problems with your gas column, you should get in touch with a qualified technician right away. Making an attempt to solve the issue on your own can be risky and potentially worsen the situation. An experienced technician has the knowledge and resources necessary to identify the problem and solve it effectively and safely.

Maintaining your gas column on a regular basis can also help keep malfunctions at bay. Plan yearly maintenance with a certified specialist to guarantee the safe and effective operation of your gas column. You can prevent unplanned malfunctions and guarantee the ongoing comfort and safety of your house by being proactive and taking care of any problems as soon as they arise.

Video on the topic

The gas column itself rumps or turns on through time – the repair of the presetate #gasolonkatu will

Repair of a gas column, the main reasons for the breakdown of the gas column

All basic malfunctions of gas columns.

What type of heating you would like to have in your home?
Share to friends