When it comes to keeping their homes warm and comfortable throughout the winter, gas heaters are a popular option for many homeowners. Vaillant is a well-known brand in the industry that is distinguished by its dependability and effectiveness. Knowing how to use your Vaillant gas heater correctly is essential for both safety and best performance, whether you currently own one or are thinking about purchasing one.
A variety of gas heaters from Vaillant are available to meet different requirements and tastes. Vaillant offers a range of models to suit different needs, including compact models for small spaces and powerful units for heating larger areas. There is something for everyone, ranging from the adaptable turboTEC series to the environmentally friendly ecoTEC models.
It’s important to become familiar with the parts and safety features of your Vaillant gas heater before getting into the specifics of turning it on. A seamless and worry-free heating experience is ensured by knowing how your heater operates and being aware of safety precautions. Every component, from the ventilation system to the control panel, is essential to the heater’s overall operation.
Let’s now go over how to turn on your Vaillant gas heater step-by-step. The specific steps might differ slightly based on the model you own, but overall the process is the same. You can quickly and easily turn on your heater and have a warm, cozy house by following these instructions.
- Information about the manufacturer Vaillant
- Design of Vaillant gas boilers
- Operating principle
- Popular models
- Technical characteristics of popular models of flow columns
- Instructions for connection and operation
- Possible faults and remedies
- Video on the topic
- Vailant MAg column overview
- Vaillant User Manual
- recall video, link below. VAILLANT gas heater. Water heating adjustment.
Information about the manufacturer Vaillant
The most well-known heating brand in Europe, Vaillant, recently commemorated its 145th anniversary. The company is well-known worldwide for its products. Today, the company employs 12,000 people across 14 businesses in eight countries. Vaillant is interested in alternative energy sources in addition to heating systems.
Officially, the Vaillant brand began in 1874 as a pump workshop. Then the industry saw a technological revolution with the introduction of the Johann Vaillant, an enclosed gas water heater. Vaillant started producing wall-mounted water heaters for homes in 1905.
Over the years, the company has not only updated its creations with the newest production technologies, but it has also looked for substitute technologies to meet the utility needs of homes. Vaillant introduces sophisticated models featuring a zeolite-gas heat pump in 2010. Zeolite’s inherent heating qualities can now be used by households for water heating. The heat pump uses secondary energy and lowers CO2 emissions, making it a novel technology for energy and heating equipment.
The first ecoPOWER 1 home water heater was introduced in 2011.0 with the production of heat and electricity. The pre-programmed, intelligent universal system is incredibly effective and eco-friendly.
The company introduced a 3 kW hybrid heat pump model in August 2012 that is paired with a boiler to provide optimal energy efficiency when operating.
More details! The company’s first Green iQ labeled products are ecoTEC exclusive, flexoTHERM exclusive, and flexoCOMPACT exclusive. Vaillant launched this line of high-quality, eco-friendly, and efficient products in 2015.
Design of Vaillant gas boilers
The heat load is a heater’s most crucial parameter. It varies from 10.0 to 30.0 kW at Vaillant. This size determines the water heating rate in liters per minute. When choosing a model, consideration is given to the weight, dimensions, and chimney cross-section size—all of which are crucial factors. These days, Valiant gas columns come with automatic start-up control via an electronic device and semi-automatic ignition via piezo ignition.
The user initiates piezo ignition by pressing the start button, which causes a spark to appear and ignite the wick, which in turn ignites the gas in the burner device. The wick burns continuously while the device is operating, which causes the gas to be consumed excessively. Therefore, electronic ignition, in which the spark appears automatically, is a more effective and ideal starting system.
The source of sparking could be regular batteries or the main electricity supply, depending on which mode the user chose when the boiler started up. An integrated generator that is powered by the incoming water’s movement provides the electronic ignition’s power supply in GRX type units with water flow rates higher than 2.2 l/min.
A draught overturning sensor, fitted to flow devices of the RXI and GRX types, senses the discharge in the column and, should it equal "0," automatically cuts off the gas supply to prevent flue gases from entering the room. The RXI type of vacuum column is designed to prevent overheating in the heat exchanger by shutting off the gas supply when the allowable limits are surpassed. The burner is a chrome-nickel steel device used for gas combustion. Two knobs on the front panel operate as the column’s control unit.
Crucial! The GRX and RXI units come with a copper heat exchanger coated with SUPRAL anti-corrosion coating and a gas pressure regulator that enables the device to operate steadily at gas parameters between 13 and 20 mbar.
Operating principle
Utilizing a vaillant gas flow water heater is simple. The draught in units featuring an open combustion chamber arises organically and is contingent upon the chimney’s height.
- When the hot water tap is opened, it passes through the gas valve reducer with integrated diaphragm.
- Due to the increase in pressure in the water pipe, the rubber diaphragm bends and acts on the plate, pushing out the water rod, which presses with a pressure of about 50 kg on the gas valve, opening it, after which the gas supply to the combustion area begins.
- At the same time the rod presses on the plate, as a result of which the batteries are switched on, providing a spark for ignition.
- After ignition of the flame, the flame sensor sends a signal to the module, which switches off the spark plug.
- After closing the hot water tap, the pressure in the water supply network decreases, the gas valve cuts off the gas supply to the devices and the heating process stops.
- The ionization sensor, when no flame is detected for 6-7 seconds, sends a signal to the control board, which shuts off the gas supply. This protection system does not allow the accumulation of carbon monoxide and its entry into the room.
- The temperature sensor is responsible for the degree of water heating, if the limit values of heated water are exceeded, the electronic control board also cuts off the gas supply.
Kindly take note! The regular flow of flue gases, their release into the atmosphere, and the avoidance of gas explosions within the room are all under the control of the draught sensor. The sensor sends a signal to the control unit, which turns off the gas supply, when it falls to"0," which might happen, for example, when the gas duct becomes blocked with soot.
Popular models
Vailant AtmoMAG exclusiv RXI gas heater with automatic battery-operated ignition and modulating burner. The burner device’s potential heat output ranges from 30.0 to 100.0%. The process is automated, and the rate of burning is set in response to variations in the heated medium’s pressure.
The semi-automatic column with piezo ignition, draught sensor, and overheating protection AtmoMAG exclusiv RXZ is another well-liked model. It features an electronic flame control sensor and an integrated modulating burner. This universal modification offers stable operation at low gas parameters and is compatible with two fuel types.
Technical characteristics of popular models of flow columns
Model | Column Vaillant atmoMAG 14-0/0 RXI |
Vaillant atmoMAG mini exclusiv 11-0 RXI | Vaillant atmoMAG pro 11-0/0 XZC+ |
Brief description | Equipped with LED indication | Presented in ergonomic and stylish design. | Presented in a modern classic design and has excellent productivity. |
Price, as of 1.07.2019, ths.rub. | 27.690 | 21.900 | 12.760 |
Capacity, l/min | 14 | 11 | 11 |
Ignition type | battery operated (electronic) | battery operated (electronic) | piezo ignition (push button) |
Color | white | white | white |
Output | 24.4 kW | 18.6 kW | 19.2 kW |
Warranty, months | 12 | 12 | 12 |
Chimney diameter, mm | 130 | 130 | 130 |
Weight, kg | 14 | 12 | 10 |
Dimensions, cm | 68×35×26.9 | 58×31×25.6 | 63.4×31×27.2 |
Instructions for connection and operation
Kindly take note! As mandated by the warranty terms, it is advised that a qualified Vaillant service perform the installation and initial start-up.
Guidelines for turning on and maintaining Vaillant gas boilers:
- Before turning on the Vaillant gas heater open the gas and water taps.
- Ignite the igniter, for this purpose press the load regulator and turn from the position "Off" to "Ignition", at the same time press the piezoelectric ignition button.
- Check the presence of the flame through the viewing window.
- Release the piezo ignition button and keep the power regulator pressed down for a while longer
about 10 sec. - If the device is not ignited, hold the regulator knob for up to 60 seconds to ventilate the gas duct and repeat the start-up with piezoelectric ignition.
- After creating a stable burning flame turn the power regulator from "Ignition" to "On" position. In this mode, when the hot water tap is opened, the heater will automatically switch on and when it is closed, it will automatically switch off.
- The water temperature is set by the thermostat on the unit"s panel. To increase it turn the knob to the right and to decrease it turn it to the left.
- To turn off the heater, turn the power regulator from the "On" position to the "Off" position while it is pressed down.
- Close the shut-off valves on the gas and water lines.
Possible faults and remedies
Since vapourant gas water heaters operate in harsh and hot environments, they will eventually malfunction; this also applies to other models of a similar nature. The reduction of such appliances’ service life is influenced by the quality of the raw water and the breaking of factory operating regulations.
Principal flaws in Vaillant models
- Wick does not light – thermocouple or gas valve is not working, they will need to be replaced.
- Unit overheats and makes noise – heat exchanger clogged with limescale. In this model it is not repaired but replaced with a new one.
- Water under the heater – leaks from the heat exchanger.
- Igniter spark does not turn on – the flame controller will need to be replaced or the igniter spark will need to be repaired.
- The appliance smokes, gases penetrate into the room – the gas duct or heat exchanger on the gas side is clogged, cleaning from soot is recommended.
- Failure of the water unit due to stretching or contamination of the rubber diaphragm pushing out the gas valve stem. It is recommended that it be replaced with a silicone diaphragm that is more resistant to constant stretching.
Model | Steps to Turn On |
Vaillant EcoTEC Plus | 1. Make sure gas and electricity are on. 2. Turn the thermostat to the desired temperature. 3. Press the power button to turn on the boiler. 4. Wait for the boiler to ignite. |
Vaillant EcoTEC Pro | 1. Check gas and electricity are on. 2. Set the thermostat to your preferred temperature. 3. Press the power button. 4. Wait for ignition. |
Especially in the winter, gas heaters—especially those manufactured by reputable brands like Vaillant—provide a dependable and effective way to heat homes. It is essential to know how to use these heaters correctly if you want to make sure that your home is comfortable and safe.
First, become acquainted with the particular Vaillant gas heater model that you own. There may be differences in features and controls even though the fundamental workings of each model are generally the same. For thorough instructions specific to your device, consult the user handbook that was sent with it from the manufacturer.
Make sure everything is in working order by doing a thorough inspection before turning on your Vaillant gas heater. Look for any indications of damage or malfunction, such as flame irregularities, strange noises, or leaks. Make prompt contact with a qualified technician to address any issues.
Pay close attention to the instructions provided by the manufacturer when lighting your Vaillant gas heater. This usually entails turning the control knob of the heater to the ignition position, pressing the ignition button, and holding down the control knob at the same time. Hold the knob in place for a few seconds after it ignites to give the flame time to stabilize.
As soon as your Vaillant gas heater starts up, keep a careful eye on it, especially at first. Make sure the flame burns evenly and steadily to indicate that the combustion is occurring properly. Keep an eye out for any strange sounds, smells, or indications of a problem in the vicinity.
In conclusion, maintaining a warm and cozy home while lowering risks requires knowing how to use your Vaillant gas heater safely and effectively. Efficient heating can be achieved without sacrificing safety if you adhere to the manufacturer’s instructions, perform routine maintenance, and exercise caution when using the system.
We’ll walk you through the easy process of turning on popular Vaillant gas heater models in this article. Understanding how to run your gas heater efficiently is essential, whether you’re bracing yourself for the harsh winter weather or simply want a comfortable space. We’ll go over the fundamentals of safety inspections, where the control panel is located, and how to ignite your heater step-by-step. Being aware of your Vaillant gas heater helps to safeguard your home’s safety and energy efficiency in addition to comfort. Let’s get started and make sure you’re warm and comfortable quickly!