How to disable the heating radiator if hot is the nuances that you need to know

Maintaining a warm and comfortable home becomes increasingly important as winter draws near and the temperature drops. The radiators in your heating system are an essential part of keeping your home comfortable. But occasionally, whether it’s for renovations, maintenance, or just changing the temperature in a particular room, you might need to temporarily turn off a heating radiator.

In order to avoid energy waste and maintain the effectiveness of your heating system, you must know how to turn off a heating radiator correctly. Even though it might appear like a straightforward task, there are subtleties and things to keep in mind in order to prevent problems or damage to your heating system.

Prior to disabling a heating radiator, it’s crucial to comprehend the operation of your heating system and the connections between each radiator. A network of pipes is typically used by a central heating system to transfer hot water or steam from a boiler to radiators throughout the house. Every radiator has a valve that regulates the amount of steam or hot water that enters the radiator.

Disabling a heating radiator starts with figuring out which valve to turn off. Thermostatic (TRV) and lockshield (LS) valves are the two valves found on the majority of radiators. By automatically modifying the hot water flow according to the predetermined temperature, the thermostatic valve controls the room’s temperature. Conversely, the lockshield valve, which is normally found on the other side of the radiator, is used to balance the water flow throughout the system.

After locating the valves, you can turn off the radiator that provides heat. Depending on the type of valve, begin by turning the thermostatic valve to its lowest setting or to the "off" position. By doing this, the hot water supply to the radiator will be cut off, gradually bringing down the room’s temperature. Next, slowly close the lockshield valve by rotating it clockwise with a radiator key or wrench. Avoid overtightening the valve as this may cause harm to the mechanism.

Step Nuances
Turn off the radiator valve Make sure to turn the valve fully to the closed position to stop the flow of hot water.
Bleed the radiator If the radiator still feels warm after turning off the valve, use a radiator key to bleed any trapped air from the system.
Check the thermostat Ensure that the thermostat is set to a lower temperature or turned off completely to prevent the radiator from heating.
Consider using a lockshield valve If you want to prevent others from adjusting the radiator, consider installing a lockshield valve and keeping the key in a safe place.

Alternative methods

The purchase and installation of a special valve will be one of the alternate methods to guard against the living room getting too hot. With a device this simple, you can store the battery’s value in ruble equivalent and control the amount of thermal energy it receives. Since the distribution of heat depends on the atmospheric conditions, apartment owners must consider the importance of the savings principle.

The plumbing device market is currently in a position where you can buy a specific protective screen that functions similarly to a blind. This screen’s wings can be turned to lessen the amount of thermal energy that is dispersed throughout the apartment and to lower the possibility of burning a hot battery. The simplicity of the lulzic screen’s device, which eliminates the need for labor-intensive installation, is another benefit of installing one. It won’t take more than ten minutes to install this kind of equipment.

Making a request to the management company’s office is the most drastic method of limiting the amount of heat that is supplied to your apartment. This appeal will cover the corresponding common house valve, thereby mitigating the thermal effect of the apartment battery. If you are the only one who needs the heat supply to the apartment restricted, then this method is not a cure-all. Using this option may have an adverse effect on your neighbors, which is not ideal.

If you need to block and remove the radiator

The best time to complete radiator removal work is after the heating season has ended. There are several considerations to make if work needs to be done during the heating season. You can only remove the battery in a single-pipe heating system with vertical wiring if there is a bypass.

Pipes indicate such a system; one originates from the ceiling and joins the radiator, while the other exits the radiator and vanishes into the floor. A jumper that connects the input and output pipes is called a bypass. This pipe is either slightly smaller or about the same diameter as the main pipes. The idea behind bypass is this: when the radiator is unplugged, water starts to move along the riser and through the bypass instead of the battery. In this instance, the riser is operational, and the heating in the apartments next door remains on.

In the event that the system consists of two pipes, shutting off the taps is sufficient before removing the battery.

Remember that the battery is always filled with water

The battery is filled with liquid throughout the year. Water drainage is carried out only for a short time in the process of centralized repair work. Therefore, if it is planned to replace the battery, just turn off it is not enough – you need to drain the water. Why the system is constantly filled with the coolant? It is extremely undesirable for oxygen to fall into the heating system. When the water merges, its place takes air with water vapor. This leads to active oxidation – that is, the appearance of rust on the surface of steel and bimetallic batteries. Oxygen dissolved in the coolant does not destroy the metal, t.e. does not lead to corrosion. Therefore, for the heating system to serve for a long time, it is always filled.

What else should you know

There is a solution here if you’re wondering how to block the battery in the absence of a crane. It’s true that in this case, the riser overlap option is unavoidable. In this instance, a portion of the heating system will also be blocked in addition to a separate battery. Small cities frequently employ the technique of independently disconnecting the heating system by simply covering the riser. A valve located in the basement is used to disconnect it. He moves toward the sunbed there. Usually, water valves are visible.

Find out from technical documentation which fittings are appropriate to block the heating. Additionally, skilled plumbers who are acquainted with local communications should be aware of this. The heating system is typically stopped by a valve or a brass valve.

In the event that the window sill overflows the battery, there is no single solution. It all depends on the degree of overlap. So, for example, if the windowsill completely blocked the battery, then this is considered unacceptable. This is explained by the concept of convection, in which warm air rises up. There he replaces the cold air, which goes down, after which it heats up with the battery. Thus, the room is heated. If the windowsill completely blocked the battery, then the convection process is difficult, and the room is poorly warmed up. But there is a solution to from this situation. You can make several rectangular holes in the windowsill and close them with decorative grilles.

  • So, the overlap of the batteries in the apartment can be carried out and, in some cases, you even need. It is most convenient to do this in the presence of special cranes.
  • After the end of the heating season, it is recommended to close one of them, and leave the second open.
  • On the day of heating, we close both taps for 1-2 days so that rusty water leaks and the possibility of blockages was excluded.
  • If there is no crane, then you will have to block the riser using a special valve or the valves that are most often in the basement of the building, and usually in a prominent place.

The most important thing is to follow all rules and regulations with meticulous thought and execution. When the heating season comes to an end, avoid closing both taps as this may cause deformations and cracks in them. Remembering the fundamental guidelines will ensure that you safely and correctly block the battery in your apartment.

In what order it is necessary to open and close the taps (valves) in batteries?

The battery has two taps on it. They warn that there could be a hydraulic blow if you close them out of order.

In order to receive heat, the air from the radiator must first be lowered. To do this, we first open the Maevsky crane (descent) and create space for additional steam (water) receipt.

We open the main crane (at the entrance) as soon as the air is lowered and wait for the batteries to warm up. While hydraulic blows are a real phenomenon, they are extremely uncommon in apartments; therefore, following basic instructions is essential to preventing accidents.

  • When starting a heating radiator, you first need to lower the air from the battery.
  • Therefore, first open the air valve, then the tap for the opening.
  • After water will go from the battery through the air valve, it will mean that the air is lowered.
  • We open both taps for the whole, the system will begin to work (water circulate).

Heating adjustment or return

With the use of "hydraulic balancing," one can modify the temperature of each heating appliance in an apartment or home to a partially adjustable degree. All batteries are equipped with cranes and thermostats to ensure a more even distribution of water throughout the system. The radiators’ "return" temperature is checked during system setup. There ought to be a 1-degree Celsius difference.

When balancing, thermal heads are left fully (maximum) open. A contact thermal attemptor, such as one found in a multimeter, is used to measure the return temperature.

Reduce the input cross section of radiators with high temperatures using the output pipe, then recheck the system.

Some tips for adjusting batteries and heating systems

  • To install regulators on radiators, only special taps and valves should be used.
  • For the batteries to give heat to the maximum, try to optimally correlate the number of angles, inclinations and pipes of pipes during installation. With an excessive amount of bends, the performance of the entire system will be ineffective, but at the same time, pressure will decrease in pipes and batteries.
  • Thoroughly isolate batteries and pipes in those rooms where heating is not so important. For example, in the pantry, garage, etc. D. Isolation will prevent the inappropriate consumption of heat on those segments of the path where its feed, in general, is not so important.
  • At the time of adjustment of the heating batteries, the premises should be fully used according to their intended purpose. This approach will make it clear what optimum temperature will be required for the comfortable operation of rooms.
  • To avoid irrational heat consumption, consider all additional sources of heating in the room, as well as factors that help cool air and the appearance of drafts: air conditioners, open windows, etc. D.
  • Start adjusting the temperature of the heating batteries with the determination of the cold room. As a rule, this is the largest and non -residential premises in the house. To do this, close all the taps and measure the temperature in the rooms. After the coldest room is determined, start tuning the batteries from it, completely opening a shut -off crane there. The room will warm up more efficiently, but at the same time the duct of the hot water will not decrease.

  • In order not to guess the temperature in personal sensations, spread the thermometers in the rooms. They do not have to be in a prominent place and have the form of a thermometer (if you worry about breaking harmony in the interior). Moreover, for example, with +20C one person can feel quite comfortable, and another temperature will seem a few low.
  • To bring the temperature in the rooms to the most comfortable value, set up the regulator on the boiler. In this case, in warmer rooms, the temperature will slightly exceed the required value.
  • Remember that the heated rooms are cooled slowly enough. Therefore, if the temperature seemed to you in the room a little high, do not lock the tap completely, but only slightly lower it. To adjust the temperature of the heating batteries to go as efficiently as possible, screw the taps in turn in each room.

Emergency shutdown of the battery

And in the event of an accident where hot water spills into the room without a shut-off valve, what should one do? Or are the nozzles not bypassed to connect to the battery? The neighbors’ brief discomfort will have to be put on hold in an emergency and prevented from obstructing the water in the battery in any way.

Yes, in the event of a breakthrough, you could lose a great deal of materially, but so could your neighbors down below, where water would also eventually reach.

Suggestions. You should have ample time to fix the problem if the leak is minor and the water only drips at the intersection. You must replace some containers and give the home locksmith or the heat supply company a call.

You have to take immediate action if there is a large leak and there is a chance the room will flood. Regardless of the absence of bypas, the cranes that are accessible on the eyeliners to the radiator must be blocked. In the event that reinforcements are not present, you must phone every emergency service that is available before attempting to block the entire riser until help arrives. You must locate the heat station of your entrance by delving into the house’s basement in order to accomplish this. Put more simply, two vertical pipes rising from a horizontal collector with a bigger diameter must be located.

It is necessary to close the taps or valves on the inserts of both pipes into the collector. Simultaneously, the riser will leave the entire building without heat, not just your apartment. It is imperative that you inspect every apartment building, inform the neighbors of the current circumstances, and post a notice on any closed valves to deter future openings while repairs are being made. You will have to wait for the locksmith or the arrival of the emergency service if you were unable to locate the required valves.

In conclusion. In the middle of winter, you can overlap your steel or cast-iron battery in two situations: first, when it permits the binding scheme, and second, in case of emergency, under any circumstance.

Opening and closing valves

Depending on the type of installed device, there are multiple ways to determine if the valve is open or closed.

Determination of the position of the ball valve

You can use the following to ascertain the ball valve’s condition:

  1. control pen;
  2. stitch.

A ball valve may have one of two handle configurations:

  • the handle, which is an oblong element attached to the body of the device;
  • Back-handle consisting of two similar parts located symmetrically relative to the fastening point.

When the handle rotates in the direction of the pipeline and the device axis, the valve opens; when it rotates perpendicular to the device and pipeline, the valve closes.

Valve condition as determined by the device’s handle installation

It will be useful for the upcoming video to ascertain the state of the valve on the handle.

Is it possible to determine the position of the valve if the handles are damaged or, for some reason, nonexistent? You can use the latch on the rod to find out how the device is doing under the conditions you are considering.

A component that lets you know where the valve is located

The valve is open and the liquid (gas) passes through if the back is parallel to the pipeline. The valve is closed and the fluid cannot move in accordance with the system if the back is positioned perpendicular to the direction of the pipes.

Using the back to determine the valve’s position

Determination of the position of the cork valve

If the device has no handle, how should one unscrew the cork valve and how can one determine the position of the valve in this situation?

In order to find the position of a valve without a pen, you will need:

  1. find on the upper part of the risk rod (risk);
  2. Visually find out the condition of the device.

Assessing the cork crane’s state when its handle is missing

Any type of valve must have its control handle or fastener rotated in a clockwise direction in order to close. The handle must rotate in the opposite direction—that is, against the clockwise movement—in order to open the valve.

Is it possible to leave a heating system without water in the summer?

Don’t let the water flow to the radiator completely overlap. Disconnecting the radiators is limited to the time that the heating system is being crimped, which is a process that involves checking for problems.

Never go more than fifteen days a year without water heating when using aluminum radiators.

Temperature norms in the room

To ensure that he has a comfortable place to live during the winter, every resident of an apartment building would undoubtedly like to have a heating regulator. Actually, not everyone is aware of it or the reasons the apartment needs heating.

Actually, it enables the following:

  1. The carrier move freely through the pipes of the heating circuit, avoiding importance. This allows him to fully give heat to the room, creating a pleasant microclimate.
  2. Makes it possible to reduce costs to 20-25%, reducing the heating of radiators. As practice shows, a decrease in air heating in a room by only 1 degree gives saving up to 6%.
  3. The adjustment of the temperature of the heating battery in the apartment allows you to increase heat supply if it is not enough.

It is best to complete any system setup or adjustment work before the heating season begins.

You must ascertain what is regarded as the norm in order to calculate how much to raise or lower the system’s temperature. According to SNiP, the temperature is +20–22 degrees in corner rooms and +18 degrees in the remaining rooms.

Based on these data, the customer can determine that if he independently cooled the apartment, adjusting the temperature of the heating radiators helped him save money, or vice versa.

Regretfully, not every residential structure can have heat regulators installed.

  1. If in a multi -storey building a vertical upper wiring of the pipeline, then installing the control valves is impossible. This means that the supply of the coolant begins with the upper floors, so there in any frost “Africa” and tenants are forced to open the windows, while on the lower floors the radiators are slightly warm.
  2. In the presence of a single -pipe system there is no such problem in the building, since the carrier, passing through all the batteries, returns back to the central riser. This allows the heat to be evenly distributed throughout all rooms, regardless of their number of storeys, and regulatory valves are installed on all heating batteries in all heating batteries.
  3. A two -pipe system, although it is considered somewhat more expensive, however, the best, both in heat supply and its adjustment. It provides for separate pipes for the supply of the carrier and returning it to the system. In this scheme, the adjustment of the heating radiator in the apartment is carried out separately in each room, since they are all equipped with special valves or automatic devices.

You can consider those who have heat transfer regulators in their apartments to be fortunate, as experience has shown. They are able to maximize spending and provide themselves with a comfortable living environment as a result.

In the article "How to Turn Off a Radiator When It"s Too Hot: Key Points to Remember," we"ll guide you through the process of effectively managing your home heating system. When your radiator is pumping out too much heat, it can make your home uncomfortably warm and increase energy costs. First, locate the radiator valve, typically found at the base of the unit. Turn the valve clockwise to reduce the flow of hot water into the radiator, which will lower its temperature. If you still find the room too warm, bleeding the radiator might be necessary to release excess air trapped inside. Remember to use caution and a cloth to catch any water that may escape. Additionally, if you have a thermostatic radiator valve (TRV), you can adjust it to control the temperature automatically. Lastly, always be mindful of any changes in temperature and adjust accordingly to ensure comfort and energy efficiency in your home.

Energy consumption for an Obvodny pipe with a thermostat

The cost of the energy carrier is positively impacted by thermostat installation. In a system with a roundabout pipe, hot water consumption drops by 30–35% and radiator heat transfer drops by 10% when compared to a conventional running pipe. When the heating system is overheating, or when the apartment is overheated, this is very important. This demonstrates how well the system uses the bypass to provide comfortable conditions in the room and how much less energy is paid for.

The correct procedure

A bypass is a short pipe that branches off of a common riser and acts as a jumper to connect the pipes. Bypass ensures that the battery is only being blocked in your apartment and not throughout the entire house. Use the taps to block the battery if your heating system is connected exactly as shown in the above figures. It becomes unclear which crane—upper or lower—should be utilized.

You should be aware from the start that you don’t have to turn off two taps! As we already know, during the winter, hot water travels through the pipes to heat the heater. There will be a dramatic drop in the interior water temperature if both taps are blocked. It appears that we require it! However, less water will be added to the radiator at the same time. Additionally, pressure inside a vacuum is created by empty space filling it.

Excessive pressure can cause the battery to crack or even explode! You only need to shut off the lower tap if you’re hot in order to easily assign blame for heating. In order to prevent vacuum and air traffic jams, the upper one stays open and the heater is fully charged.

In other words, your process consists of three steps:

  • Feel that you are hot.
  • Make sure your system is equipped with cranes and bypass.
  • Close the lower tap, but do not touch the upper.

What to do with a jammed ball crane

Ball valves can sour and jam if they are not rotated for an extended period of time. Under no circumstances should you attempt a physical resolution or rape the "butterfly" with pliers or a gas key. Due to its delicate alloy composition, it is bound to break. Take this action:

  1. Unscrew the fixing nut and remove the “butterfly” type handle from the rod.
  2. On most of these valves, a nut that clips a plastic oil seal will be found under the handle. Loosen it, turning the key to half a turn. If there are no nuts, go to the next point.
  3. Take a divorce key or another device that allows you to reliably grab the baldness on the rod. Without making great effort, turn it as much as possible.
  4. When you feel the resistance, turn the stem back to the stop and again forward, trying to crank it a few more degrees. Work carefully and without haste!
  5. In this way, develop the rotation of the valve 90 °, then tighten the tank nut and set the handle in place.

One can firmly grasp the divorce key from behind.

Suggestions. Apply WD-40 aerosol lubricant, if available, to the stem and let it sit for five to ten minutes before rotating.

During the heating season, take extra precautions to avoid blocking the batteries with acidic cranes. You will exert too much effort and rush the situation, which could result in the valve housing bursting or breaking off a metal rod or ball. A burst of steaming water could come from a crevice and burn you. As you descend to the basement and turn off the heating, the coolant will corrode the interior of the room. You can roughly estimate how much the apartment will cost to fix at this point.

Dial the masters, the plumbers, if you are unsure of what you are doing. See the video to learn more about how to close the jammed ball crane and turn off the heating batteries.

Is it possible to block the battery in winter?

It is forbidden to interfere with the operation of centralized systems during the heating season. Certain emergency scenarios, such as holes, leaks, and so forth, are exceptions. However, you won’t freeze any of your neighbors if the radiators are connected to the system sensibly and block the battery during the heating season. This is referring to the typical schematic, as seen in the picture, that connects the radiator with two ball valves and a bypass line:

Everything is very easy if your heating devices are connected to the riser in this manner: shut off both taps if needed, then reopen them after working. You can manually turn off the battery for a while, even in the sweltering heat, to avoid opening the windows. However, in these circumstances, it is preferable to equip radiators with thermostatic valves to maintain the room’s appropriate temperature.

The heating radiator can be disconnected from the system at any time of the year if needed, thanks to the proper connection:

  • make its color;
  • perform washing;
  • change the battery without overlapping the riser.

What is required for safe work?

Installing a temperature control controller on the battery is an option to think about when the apartment gets really hot and the owners want to block the heating radiator. When bypas are present, the room’s temperature is controlled by a thermostat that is mounted on the radiator. The regulator, which controls the temperature in this apartment as well as the riser shared by the neighbors, cannot be adjusted if the bypass is missing. All you have to do in this case is install the bypass and replace the heating radiator.


Bikes node and functions

When there is hot water circulating, you can perform repairs with bypass at any time of year, even during the winter. Blocking the crane in front of the radiator is the only worthwhile endeavor. The circulation will go through the bypass itself as soon as the water stops entering the pipes. By doing this, the apartment’s owners will be able to avoid using the common riser and going down to the basement.

The actual device is made up of pipes with a smaller diameter than the feed and lifting line pipes. The two ball valves that are present enable you to properly overlap the radiator and steer the water circulating through the bypass.

The purpose of Bypas is to control the energy carrier. It enables you to temporarily block the system in the room when it is extremely hot. The room will instantly cool as a result of the hot water not reaching the radiator. You must first block the water when changing the battery and then open it back up when the installation is complete.


The bypass will stop the hot coolant supply to the pump when the water circulation in the system with an electric pump fails. This will take place via a redirected pipe. Simultaneously, the valve opens, directing the water directly along the central pipe, resulting in circulation without the need for a pump.

Put the bypass and the battery in place. However, experts advise making the bypass immediately.


Thermostat: role and possibilities

Nonetheless, you can adjust the thermostat to better control the room’s temperature. When needed, the battery can be turned off from the system as a whole with this device. You can reduce your water usage by installing a thermostat. After all, the second consumption drops to 35 percent when comparing the hot water in the bypass pipe with regular running water. When the room is hot, it matters.

The thermostat functions as a control valve, regulating the amount of water that enters the radiator. These thermostats come with a number of features. The water enters the battery at full support if it is fully open. There is absolutely no water entry into the radiator when the thermostat is closed.

It’s important to remember, though, that jumpers are the only way to install the thermostat. These models facilitate unobstructed water circulation. Additionally, they guard against clogging the thermostat itself. The valve is protected by jumpers that are placed in front of it. Ultimately, the thermostat will cease to pass water if it becomes contaminated. Jumpers should therefore always be left open. When batteries need to be flushed, which is an uncommon circumstance, you can temporarily close them.

Drill hole and ball valves

Installing ball valves on the pipes makes it much easier to overlap radiators. Any overlap will happen very easily with their assistance. Simply rotate the crane to make the water stop penetrating the battery.

The work of overlapping the radiator will be much easier if there is a drain or specialized crane available.


Gases divert

Remember that distinct chemical processes will still occur inside the room’s radiators even if you block them, leading to the differentiation of gases. They won’t be able to move since the radiator is blocked. And a battery break could result from this. Consequently, in order to remove gas, the radiators must always be installed.

These days, batteries come fitted with them. Both manual and automatic are available. The former eliminates the gas buildup as it occurs within the battery. For the summer, heating devices can therefore be blocked, but only after a gas device has been opened. With a manual crane, the valve is turned counterclockwise to release extra gas.


What are heat regulators?

The heating battery’s electronic thermostat

The heat regulator is a unique adjustment valve that regulates how much water enters the battery. Five regulatory requirements are usually established: when the valve is fully open, hot water flows into the radiator to the full extent of its diameter in the pipe. When the valve is fully closed, water cannot enter the battery.

Take note! Without jumpers, thermostats cannot be installed. It is not acceptable for the system as a whole to have less hot water flowing through the radiator due to a decrease in its duct. There is no obstruction to the water’s circulation when jumpers are present.

Dirt and trash inside the heating battery

In addition, jumpers protect the thermostat from clogging during the first connection, as well as an accident on the heating main. The valve must be placed after a jumper, in this case it will be sufficiently protected from pollution. Do not forget that the thermostat is not adapted to pollution. As a result, the formation of a mound that does not pass hot water through the batteries is not excluded, and this is fraught with the capture of the entire riser. Therefore, jumpers should be left open all the time, with the exception of the situation when the radiators are clogged, and their washing is required. In this case, the valves overlap for the duration of the washing of the batteries, and then open again.

Heating battery cleaning and flushing

How to correctly block the heating battery if it becomes hot

When turning off the heating for the summer and before the heating season to repair or replace radiators, as well as when the apartment is heated, the batteries will need to be blocked. The topic of how to properly block the battery in the event that the room is heated is one that interests us. When a clever device known as a bypass crossbar is placed between the supply and removal pipes and is frequently outfitted with shut-off valves and a heat regulator, it becomes quite easy to accomplish this. The apartment’s rags offer the chance to obstruct water flow and set up workarounds when installing heating equipment.

Turn off the heating battery.

Because the system still circulates hot water in the winter, repairs can be made thanks to the bypass. All that is needed to accomplish this is to shut off the hot water supply by simply closing the tap in front of the battery, which directs circulation through the bypass. Because you will need to disconnect the riser for the duration of the repair work, you do not need to go down to the basement for a temporary overlap of the system, which would cause inconvenience to the neighbors. Installing a second shut-off crane at the apartment’s heating system entrance is the best course of action.

Baypas thermostat installation

Take note! Water must always be blocked in the system when replacing pipes and batteries in order to prevent corrosion. Precautions should be taken in the winter to prevent hot water burns.

Three-way valve

A three-way valve, as seen in the below photo, is an unconventional method of regulating the temperature of heating appliances. It is positioned on the supply pipe that leads to the battery and the bypass. To ensure that the radiator’s heating level is consistently maintained, the device needs a thermoregulatory head.

  • In case of temperature rises near the head, the supply of the coolant to the battery stops above the required, the fluid flow moves through the bypass.
  • When cooling occurs, the valve opens again, and the radiator heats up.

This adjustment technique is applied to vertically wired single-pipe systems.

Crucial! The coolant in apartment buildings with central heating typically contains foreign particles that cause thermostats to become clogged. As a result, three-way valves and manual cranes can be installed in apartments without raising any red flags.

Installing automatic regulators necessitates placing filters in front of them, which need to be cleaned on a regular basis.

Councils of specialists

Experts recommend using the following devices consistently during the heating season to prevent the heating batteries from being blocked:

  • Ball valves;
  • Bypass with a valve;
  • drainer;
  • thermal regulator;
  • Gas excess removal device.

The best course of action is to contact special services in order to block the apartment’s heating battery while also preventing any harm to the neighbors. On the other hand, in an emergency, you should immediately turn off the heating rather than panicking. Studying the locations of currently installed overlapping devices is important in order to accomplish this.

Watch the video below to learn how to reduce the air coming from a radiator in a multi-story building.

The owner of a private residence with an autonomous heating system is free to disconnect the boiler whenever the street’s weather warrants it or for other reasons.

In order to prevent the heating device from operating, ball valves must exist.

For those who reside in homes with central heating, there are typically two scenarios in which inquiries about blocking the heating battery come up:

  • If warm weather has been installed on the street, and the central heating has not yet been disconnected, since the officially heating season is not completed;
  • If necessary, replace, repair or paint the radiator, repair the wall behind the battery.

It’s important to remember that coolant is continuously present inside the battery at this point. It is only emptied when system repairs are necessary. This is because the majority of the heating equipment that was installed in the old building’s homes, along with the wiring within each individual home, are composed of steel.

A certain amount of dissolved oxygen is present in the fluid inside the heating battery. This oxygen eventually reacts with the metal completely, stopping corrosion.

A steel or cast-iron battery’s inner surface has moisture that does not evaporate over time in a closed space, making it impossible for the system to remain empty for an extended period of time or for a separate heating device to be fully functional.Corrosion processes are accelerated dramatically by this. As a result, the heat carrier only merges in rare circumstances.

How to turn on the heating battery for the first time for the first time

A very important point is the first inclusion of a central heating battery in your home. Когда прошел длительный интервал времени, и ТЭЦ начинает подавать нам воду в батареи, то обычно первая вода, идущая через отопительные системы, самая грязная и ржавая. Imagine. You have just put a brand new battery, you can say from the conveyor, and there you gave a powerful stream of dirt there once. It is not surprising that many batteries clog precisely from the first such inclusion, and then we are surprised that out of 12 knees, only 8 batteries, the rest remain cold. So that this does not happen, when installing the battery, just a jumper (bypass) is necessary. If you correctly made installation, then set the position of ball valves as shown in the figure:

In this instance, the jumper will be completely filled with dirt when it is first turned on, protecting the integrity and preservation of your battery. For a few days, hot water is preferable in this scenario. Naturally, a lot of people are eager to see when it turns on. My recommendation is to wait at least one day if you are unable to wait a few days. A thorough guide explaining how to disconnect the battery, on the other hand, is available.

Do I need to put the taps on radiators

There is an opinion that if there is no need to adjust the power of the battery, then you do not need to put the taps on it. This judgment is not true … Each heating radiator, sooner or later, needs to be maintained or replaced, and without cranes this procedure will be more difficult and more expensive. In other words, nothing happens eternal, it also applies to heating radiators. Each heating device can clog sooner or later, lose the appearance (in this case, we can offer you to paint the heating radiator) or fail (flow). If cranes are installed in front of the radiator, then its dismantling and re -installation (or installing a new same radiator) is not problems. If there are no cranes, then the maintenance or replacement of the radiator is a complex and expensive process. Therefore, the answer is definitely yes, you need to put cranes on any battery.


It’s crucial to understand how to correctly disable a radiator when it comes to controlling your home’s heating system. Knowing the ins and outs of radiator shutdown can be very helpful, whether you’re doing repairs, remodeling, or just trying to save energy.

The most important thing should always be safety. Make sure the heating system is completely off before attempting to disable any radiators. This keeps hot water from spilling through the radiator while you work on it, preventing any accidents or injuries.

Next, become acquainted with the particular kind of radiator you own. Different systems might use different techniques to turn off individual radiators. It will save you time and aggravation to know how to correctly disable your radiator, whether it is a steam radiator or a conventional hot water radiator.

It’s time to find the shut-off valve after you’ve turned off the heating system and determined which type of radiator you have. This valve is usually found on the radiator itself or on the pipe that goes to it. This valve can be turned clockwise to completely disable the radiator by stopping the supply of steam or hot water.

It’s crucial to bleed the radiator after closing the valve in order to release any pressure that may have built up and guarantee a thorough shutdown. The bleed valve at the top of the radiator can be opened with a flathead screwdriver or a radiator key. There may still be steam or hot water, so proceed with caution. You will know the radiator is completely deactivated when all of the pressure has been released and only water is dripping out.

In conclusion, it takes close attention to safety precautions and knowledge of your particular heating system to disable a heating radiator. When it comes to repairs, renovations, or energy conservation, you can safely turn off a radiator by following these instructions and understanding the subtleties involved.

Video on the topic

Two cranes on the battery are already the problems of residents

The apartments are hot

How to block the battery

Video: how to block the heating battery if the apartment is hot?