How to correctly install an expansion tank in the heating system

Maintaining a dependable boiler or furnace is not the only thing needed to ensure effective heating in your house. It all comes down to comprehending the many parts of your heating system and how they interact to maintain a cozy and warm environment in your home. The expansion tank is one such important part. We’ll go into the significance of the expansion tank in your heating system as well as the proper installation techniques to ensure maximum performance in this guide.

Let’s first understand the function of the expansion tank before moving on to the installation procedure. Water is heated and expands as it absorbs heat in a heating system. Pressure within the system may build up in the absence of a mechanism to handle this expansion, which could potentially damage valves, pipes, and other parts. The expansion tank enters the picture now, serving as a buffer to take up the extra water volume and keep the system’s pressure levels at ideal levels.

You may be wondering how to determine whether an expansion tank is necessary for your heating system. An expansion tank is probably required if your heating system is closed-loop, which means that water constantly circulates through pipes and radiators. Indications that your system is missing this essential part include noise coming from the boiler or frequent pressure relief valve discharge.

Precision is essential when installing an expansion tank. Your heating system’s effectiveness and safety can be jeopardized by even the smallest error. The procedure entails determining the tank’s ideal placement, making sure it is the right size, and correctly attaching it to the system’s plumbing. Despite the installation’s intimidating appearance, it can be completed successfully with the correct assistance and close attention to detail.

Additionally, it’s critical to select the appropriate expansion tank type for your particular heating system. Diaphragm tanks and bladder tanks are the two main kinds. Whereas bladder tanks have a detachable bladder inside, diaphragm tanks use a flexible membrane to keep the water and air apart. Making the right decision can be aided by speaking with an expert or consulting the specs of your system. Each type has benefits and works best for specific applications.

You can make sure that your heating system runs effectively and safely for many years to come by being aware of the importance of the expansion tank and by following the right installation procedures. The longevity and efficiency of your heating system depend on the expansion tank being installed correctly, which is an investment worth making when it comes to your family’s comfort and well-being.

Where the expansion tank for heating is installed

Thus, the type of heating system and the tank’s intended use determine how the tank should be installed. It’s not a question of what the expansion tank is used for, but rather where it should be placed to account for water expansion. That is to say, there might be several of these vessels in a private home’s heating network rather than just one. These are the roles that have been allocated to the different expansion containers:

  • compensation for thermal expansion of water in closed heating systems;
  • In open networks, the tank performs 2 functions – perceives the excess volume of the coolant and removes air from the system to the atmosphere;
  • Under certain conditions, a membrane tank serves as an addition to the standard expansion tank of a gas boiler;
  • absorb excess heated water in a hot water supply network.

The water in the tank comes into contact with ambient air in open heating networks. As a result, the expansion tank installation is situated on the riser that emerges from the boiler, which is the highest point. These systems are frequently gravity-based, with large numbers of coolant and larger pipeline diameters. The tank’s capacity should be suitable and equal to roughly 10% of the water’s total volume. Where to put such an overall tank if not in the attic?

Citation. Tiny expansion tanks for an open heating system are situated in the kitchen of one-story old buildings next to the floor gas boiler. It makes sense that a container beneath the ceiling would be simpler to manage. It’s true that the interior does not look too good. To say it softly.

The membrane expansion water for water in closed heating systems is totally sealed, setting them apart from other systems. The best place to install is next to the other equipment in the boiler room. In a small house, the kitchen is another area where a closed expansion tank may need to be installed for heating because the boiler is located there.

When operating on non-freezing coolant in closed systems, the tank’s volume ought to be raised to 15% of the total amount of liquid. The cause is that glycol antifreeze has a higher coefficient of thermal expansion.

About additional containers

Wall heat generators with built-in tanks that detect an excess of heated coolant are available from manufacturers. Sometimes there is insufficient capacity, and the tank’s dimensions don’t match the wiring for the home heating system. An extra expansion tank for a wall boiler is installed and the liter calculation is done in order for the heat carrier pressure when heated to be within the typical range.

For instance, without replacing the highways, you converted an open gravity system into a closed one. Heat load was used to choose the new heating unit. It takes more than a built-in boiler container to cause water to expand that much.

Another illustration would be heating a two- or three-story building with warm floors in every room and a network of radiators. Here, the coolant volume will also be very high; the small tank will not be able to handle the increase, and the system pressure will rise as a result. For a boiler, a second expansion tank is required.

Notably, the room contains the second reservoir, a closed membrane container that aids the boiler.

A similar issue occurs when the house’s indirect heating boiler is powered by the hot water supply: where to store extra sanitary water from the driveway? Installing a reset valve, like on an electric water heater, is a straightforward fix. However, a 200–300 liter indirect heating boiler will lose an excessive amount of hot water through the valve. Selecting and installing an expansion tank for a boiler is the right course of action.

Reference: A compensating tank can also be connected to some manufacturers’ buffer containers (also known as heat accumulators). Additionally, professionals advise installing it even on large, spacious electric boilers, as demonstrated in the video:

How to put a tank correctly

Some guidelines to follow when installing an open tank in the attic are as follows:

  1. The container should stand right above the boiler and connect with it a vertical riser of the supply line.
  2. The body of the vessel must be carefully insulated, so as not to waste heat to heating the cold attic.
  3. It is imperative to organize emergency overflow so that in an emergency, hot water does not flood the ceiling.
  4. In order to simplify the control of the level and recharge, it is recommended to bring 2 additional pipelines to the boiler room, as shown in the tank connection diagram:

Note: Sending an emergency overflow pipe to the sewer is standard procedure. However, some homeowners bring it back under the roof straight to the street to make the task easier.

An expansion tank of the membrane type can be installed in any orientation, either vertically or horizontally. Large containers are typically placed on the floor and small ones are typically clamped to the wall or suspended from a special bracket. One thing to keep in mind is that, unlike service life, a membrane tank’s performance is independent of its orientation in space.

If a closed vessel is positioned vertically upward, it will endure longer. As the membrane eventually runs out of resources, cracks will start to show. Air from the camera will swiftly enter the coolant when the tank is positioned horizontally, and he will replace it. It is imperative that you install a new expansion tank for heating. The effect will manifest sooner if the container is hung "upside down" on the bracket.

When the chamber is in a normal vertical position, the coolant will grudgingly rise to the top while air from the upper chamber gradually enters the lower through the cracks. Heating will function correctly up until the size and quantity of cracks reach a critical point. You won’t notice an issue right away because the process is lengthy.

A decrease in pressure within a home heating network is a clear indication of significant wear and cracking of a membrane in an expansion closed tank. Monitor the manometer’s testimony in the security group on a regular basis.

But regardless of how you position a vessel, you should follow these guidelines:

  1. The product must be placed in the boiler room so that it is convenient to serve it. Do not install floor apparatus close to the wall.
  2. During the wall installation of the expansion tank of the heating system, do not put it too high so that when servicing do not have to reach the cutting tap or air spool.
  3. The load from the supply pipelines and the cutting reinforcement should not lie on the tank pipe. Fix the pipes together with the taps separately, this will facilitate the replacement of the tank in case of breakdown.
  4. It is not allowed to lay the supply pipe through the floor through the passage or hang it at the height of the head.

Methods of connection

Correctly connect the tank hydraulically at a point on the reverse line that is in front of the circulation pump and boiler (if you look in the direction of the water flow). One requirement must be met before the tank can be connected to the supply: the pump needs to be on the feed line and remain in front of the compensating capacity.

In a split second: a supply-connected tank will start to fill with ferry when a solid-fuel boiler overheats. Since steam and air are compressed environments, the rubber "pear" will no longer be able to offset the expansion of the water.

The expansion tank should always be connected to the heating system correctly using an American operating a cutting ball crane. The reservoir can then be rapidly changed and disabled whenever necessary without having to wait for the coolant to cool. The container can be pre-emptied if the tee and second valve are installed on the eyeliner in the manner indicated by the connection diagram:

Suggestion made. A connection between the expansion tank and the cold water supply line at the drive entrance should be made when strapping an indirect heating boiler with a boiler and DHW. Here, a unique tank designed to withstand the pressure of the water supply network is utilized. Hydraulic accumulators or heating containers are inappropriate. Watch the video to learn how to tell them apart:

How to check and pump up an expansion tank

It is essential to verify that the pressure within the tank’s air chamber matches the pressure within the heating network prior to connecting and adding coolant to the tank. To accomplish this, unscrew or remove the plastic plug from the side of the air compartment. Underneath the plug is a standard spool that you may recognize from car chambers. Pressure can be measured using a manometer, lowered by pressing the stitch on a spool, or pumped using a pump.

For instance, the network’s estimated pressure following filling ought to be 1.3 bar. The expansion tank’s air compartment must then be filled to 1.1 bar, or 0.2 bar less than before. The main point is that the water side of the rubber "pear" of the tank is being pursed. If not, automatic air vents will cause the compressed coolant to tighten the air during cooling, which is unacceptable. Once the boiler is tuned, turn on the water, add coolant to the entire system, and then gently start the boiler.

Note: Some manufacturers list the factory pressure in the air compartment on the packaging for their products. You can select a suitable tank and avoid messing around with pumping on it.

Step Description
1 Choose the right location for the expansion tank, preferably near the boiler.
2 Turn off the power to the heating system to ensure safety.
3 Shut off the water supply to the heating system.
4 Drain some water from the system to relieve pressure.
5 Mount the expansion tank in a vertical position using a bracket.
6 Connect the expansion tank to the system, ensuring proper alignment.
7 Repressurize the system according to manufacturer"s instructions.
8 Turn the power back on and check for leaks.

Your heating system needs an expansion tank installed in order to operate safely and effectively. An accumulation of pressure that could harm pipes, valves, and other parts is lessened by the expansion tank, which allows water to expand and contract as it heats and cools. Your heating system will function efficiently and dependably if it is installed correctly.

It’s crucial to install an expansion tank that is the proper size and type for your system. Think about things like your heating system’s size, the volume of water, and the operating pressure. An expert in the field can assist in determining the right tank capacity and guarantee system compatibility.

The expansion tank’s placement is also crucial. It ought to be situated close to the boiler inlet on the boiler’s supply side. This shields it from potential harm by enabling it to absorb excess pressure before water enters the boiler. Make sure the tank is firmly positioned and appropriately sustained to avoid leaks or impairment.

Maintaining the longevity and efficacy of your expansion tank requires regular maintenance. Check the tank for damage, leaks, or corrosion on a regular basis. Replace the tank if needed. To maintain peak performance, you should also periodically check the pressure in your heating system and make any necessary adjustments.

All things considered, keeping your heating system safe, long-lasting, and efficient requires proper expansion tank installation. You can make sure that your system runs smoothly and dependably for many years to come by adhering to the recommended guidelines and getting expert assistance when necessary.

In our guide on installing an expansion tank in your heating system, we emphasize the importance of doing it right for optimal performance. The expansion tank acts as a buffer, accommodating the water"s volume changes as it heats up and cools down, preventing pressure buildup that could damage your system. Firstly, choose the right size tank based on your system"s specifications and needs. Then, install it correctly, ensuring proper positioning, secure connections, and appropriate pressure settings. Regular maintenance, including checking for leaks and ensuring adequate pressure, is essential for long-term efficiency and safety. By following these steps, you"ll ensure your heating system operates smoothly, saving you both energy and money in the long run.

Video on the topic

How to install an expansion tank more correctly.

How to install an expansion tank correctly.

How to install an expansion tank correctly.

Where to install an expansion tank correctly

90% of people do not know about it! / How to install an expansion tank correctly?