Error 4C. Buderus gas boiler. Troubleshooting

Although a gas boiler is an effective way to heat your house, what happens if it begins to display an error code? Error 4C is a problem that many owners of Buderus boilers encounter. Knowing how to solve this issue will help you save money and time. Let’s examine the reasons behind Error 4C in your Buderus gas boiler and how to fix it.

Error 4C on your Buderus gas boiler indicates that there is either a fan speed issue or that the boiler is not operating at all. The fan is essential to the combustion process because it provides the air that the boiler needs to run effectively. However, Error 4C may occur if the fan isn’t operating properly. This error can be worrisome, particularly in the winter months. Don’t worry, though; solving this problem is doable and doesn’t always call for expert assistance.

When you get Error 4C, one of the first things you should look into is the fan’s actual condition. The fan’s ability to operate may be hampered by dust or debris building up on the blades over time. First, let the boiler cool down by turning it off. Examine the fan as soon as it’s safe to do so. If it’s dirty, give it a thorough cleaning with a gentle brush or cloth. Water and strong chemicals should not be used on the fan as they can harm it.

The fan’s wiring and connections should be examined if cleaning the fan doesn’t fix the problem. Error 4C can occur when a fan malfunctions due to a loose or damaged wire. Examine the wiring closely to make sure all of the connections are safe and sound. Gently tighten any loose wires that you find. It will be necessary to replace any damaged wires that you discover.

It might be necessary to replace the fan entirely if inspecting the wiring and cleaning the fan don’t resolve the issue. Error 4C can occur when fans wear out and become less effective over time. A professional technician may be needed to assist with the more complex task of replacing the fan. However, you can do it yourself if you have the necessary equipment and knowledge.

Always put safety first when troubleshooting Error 4C in your Buderus gas boiler. It’s best to get professional assistance if you have questions about any step or run into a more complicated problem. You can make sure your house stays warm and cozy all year long by taking quick care of Error 4C.

Error 4C Buderus gas boiler troubleshooting
Problem The boiler is reporting Error 4C
Possible Cause Low gas pressure, ignition failure, or a faulty gas valve
Solution Contact a qualified technician to check and adjust the gas pressure, inspect the ignition system, and replace the gas valve if necessary

Main Thesis: An issue with the ionization flame rod or the connection between it and the ionization module is indicated by Error 4C in a Buderus gas boiler. This error causes the boiler to stop working, which can be uncomfortable and even cause damage. The ionization flame rod must be inspected, cleaned, and the connection between the rod and the ionization module must be made securely as part of the troubleshooting process. Should the problem continue, it may be a sign of a malfunctioning rod or module that has to be replaced. The Buderus gas boiler can be kept operating efficiently and continuously by performing routine maintenance and acting promptly to prevent this problem.

Error 4C

When the Buderus boiler displays the "4C" indication, the safety thermostat has tripped due to overheating. In any case, you ought to begin disassembling the boiler right away in order to identify the root of the problem. It must cool; this should take no more than 15 to 20 minutes, but first, the following must be done:

  1. Turn off the boiler.
  2. Disconnect the power supply (remove the plug from the socket).
  3. Close the gas supply tap.

A primary heat exchanger’s inadequate heat removal or lack of circulation are frequently the causes of this kind of issue.

The filter, which is situated on the heating system’s return line, must first be checked. If it seems to be clogged, just clear the blockage.

Granular filter

Checking the thermostat

In order to carry out this process, you must take a few easy steps:

  1. Unfold the control panel by removing the two screws at the bottom of the boiler. A Phillips screwdriver is required.
  2. The panel is free. Now it is necessary to lower it down and turn it towards itself.
  3. To remove the front panel, unscrew the 2 self-tapping screws securing it.
  4. The panel is lifted up and removed from the lock.

The gas boiler supply’s safety thermostat

Once the necessary preparations are completed, you can move on to troubleshooting the safety thermostat, which is situated on the main heat exchanger. This sensor opens the contacts when it overheats, but the contacts should close again when it cools down. There are a few easy steps to doing this:

  • disconnect the connectors;
  • turn on the multimeter;
  • set the electrical circuit test mode;
  • Check for contact closure.

Reinstalling the connectors is required if the device indicates that there is electricity in the circuit before moving on to additional diagnostics. This is not the cause of Error 4C.

Circulation pump operation

It’s time to examine how this element functions now. First, place napkins or a cloth underneath it. Next, remove the cap nut with a flat screwdriver. Verify that the rotor is not obstructed by checking it. Using a screwdriver, you must turn it to accomplish this. Replace the plug nut on the plug.

To test, plug the unit in, turn on the boiler, and unlock it by pressing the "reset" button. At this point, the fan and boiler should both start, and you can use the indicator to determine which way the boiler is rotating. If the direction of rotation is not indicated by the indicator, there is a problem with the pump.

Circulation pump for boilers. It could be a different brand for you. It is sufficient to remove the middle screw with a flat screwdriver in order to gain access to the rotor.

You can also visually verify your guesses. Remove the cap nut and closely inspect the rotor’s functioning.

Pump diagnostics

Before troubleshooting the Buderus boiler, disconnect it from the mains. Utilizing a multimeter set to AC test mode with a 1000V limit, examine the 230V power supply that powers the pump from the board.

Disconnect the connections, plug in the power source, and turn on the boiler prior to the test. The unit needs to be turned off as soon as the gas burner ignites. The fan and pump will keep operating in this scenario.

The pump needs to be replaced if the board is providing power to it. Cut off the power source.

Proper maintenance and familiarity with common error codes are essential for your Buderus gas boiler to operate efficiently. One such code that may suggest a number of possible problems is error 4C, but debugging it doesn’t have to be difficult. Most of the time, you can solve the issue on your own without consulting an expert by following a few easy steps.

First off, don’t panic if your Buderus gas boiler displays the 4C error code. Usually, this code denotes a problem with the ionization current during ignition. But, it’s frequently brought on by straightforward issues that are simple to resolve. Make sure the ignition electrode is clean and positioned correctly before proceeding. Oftentimes, the problem can be fixed with a straightforward tweak or cleaning.

The combustion air fan or the gas valve may be the source of the problem if cleaning the ignition electrode is ineffective. To begin with, make sure the combustion air fan is free of obstructions and operating properly. Make sure the gas valve is open and supplying gas as needed by checking it as well. In many cases, resolving problems like a closed valve or clogged fan will remove the 4C error code.

Low gas pressure is another frequent reason why the 4C error code appears. An error code may appear and interfere with the ignition process if the gas pressure is too low. Check the gas pressure and, if needed, adjust it to the manufacturer’s recommended levels to fix this. To guarantee safety and correct operation, a qualified technician should be the only one to adjust gas pressure.

It might be time to get help from an expert if you’ve tried all the above solutions and the 4C error code persists. Expertise and equipment are needed for a certified technician to identify and resolve more complicated problems with your Buderus gas boiler. Trying to solve these more complicated problems on your own may result in more harm or jeopardize safety.

In summary, you don’t need to panic if your Buderus gas boiler displays the 4C error code. You can usually fix the problem on your own by doing a few basic troubleshooting steps, like checking the gas pressure, combustion air fan, and ignition electrode. To guarantee the safe and effective operation of your boiler, it is best to seek the assistance of a qualified technician if the issue continues.

Video on the topic

Resetting Buderus Logamax U72 24K errors. ( Error 6a. )

Buderus Logamax U072 boiler overheats Repair Buderus boiler at error 4C

Buderus Logamax U072 – 24K boiler error 4C

Error 4C code indication Buderus Logamax U072 boiler 🛠 Cause and remedy 🔆 SIVTERMO

buderus wall mounted boiler reset factory settings

What type of heating you would like to have in your home?
Share to friends
Sergey Ivanov

I like to help people create comfort and comfort in their homes. I share my experience and knowledge in articles so that you can make the right choice of a heating and insulation system for your home.

Rate author
vDomTeplo.com
Add a comment