Buderus Logamax u072 gas boiler. Error 6A. Finding the cause of the malfunction

Reliability is key when it comes to maintaining a warm and cozy home environment. Due to its effectiveness and efficiency, the Buderus Logamax u072 gas boiler has become more and more popular. But just like any other appliance, problems can occasionally arise. An issue that frequently arises for users is the "Error 6A" code flashing on the screen.

It can be unsettling to see an error code on your boiler, particularly if you depend on it for hot water and heating. On the Buderus Logamax u072, error 6A denotes a particular issue that requires fixing. It’s important that you take action because failing to do so could result in more damage being done and unsafe boiler operation.

Recognizing the root cause of Error 6A is the first step in fixing it. This error code may indicate a number of problems, from small problems to larger malfunctions. It might have to do with sensors, parts of the boiler, or even the gas supply. Finding the underlying cause will enable you to assess whether you can resolve the issue on your own or if professional assistance is required.

Luckily, there is a methodical approach to troubleshooting Error 6A on the Buderus Logamax u072. If you have a little patience and knowledge, you can usually identify the problem and take the necessary action. We’ll walk you through the process in this article to identify the problem’s root cause and assist you in getting your boiler operating again.

Advantages of the Buderus Logamax U072 boiler

The following are some of the primary advantages:

  • affordable cost;
  • versatility and modern style;
  • small size allows you to save useful space;
  • updated user interface;
  • informative LCD display;
  • operates on the basis of a plate heat exchanger;
  • You can connect a room thermostat;
  • low noise level;
  • modulating fan;
  • minimal risk of installation errors.

Even the most reliable and sturdy appliances occasionally experience malfunctions. However, you can solve some problems on your own.

Diagnosis and repair

Error 6A is the most frequently occurring error on the Buderus boiler display. The acronym for "ignition problems" is this. You can attempt performing diagnostics on your own to find the source and fix the issue.

First things first, in the event that such an error arises, you must take the following actions:

  1. Check if there is gas in the house.
  2. Check if the gas supply tap located under the boiler is open.
  3. Press the "Reset" button on the control panel to restart the boiler.

The automation may have blocked the boiler due to a gas cut-off accident on the main gas line. When the gas supply is back on, the boiler will operate normally.

If this kind of error keeps happening, the following actions must be taken:

  1. Turn off the device using the appropriate button on the control panel.
  2. Disconnect from the power supply.
  3. Cut off the gas supply by blocking it with the tap.

With a Phillips screwdriver in hand, you must now remove the control panel. Remove the two screws at the bottom for this purpose. The panel needs to be carefully lowered and turned towards you once the bolts have been removed.

Two self-tapping screws must be removed in order to remove the front panel. In contrast, this panel must be raised in order to be taken out of the boiler. It is required to disassemble the boiler furnace cover in order to assess the state of the gas burner, ignition electrodes, and flame control. Five screws can be removed with a screwdriver. After that, slightly lower the lid and take it off.

The furnace’s main components include a gas burner, a copper heat exchanger, an electrode for ignition on the right side, and an electrode for flame control on the left.

Spark test

The following is the sequence of steps for verifying the spark:

  • Connect the unit to the power supply;
  • restart the device by pressing "Reset".

Since the spark should be beating steadily, there must be another issue. After disconnecting the power supply, keep looking for the Buderus boiler’s error 6A cause.

Verify if this plug is providing the spark.

Gas pressure and automatics

This part of the test will require the use of a micromanometer. Turning it on is necessary, but first it’s crucial to calibrate the device by hitting the zero button. Experts advise removing the left side panel to make work more convenient. Many screws holding the panel from the front and bottom sides must be removed. Additional work is completed in accordance with the following schedule:

  • disconnect the ignition cable and the clips that hold the control panel in place;
  • remove the insulation gasket from the side cover;
  • Remove another set of screws holding the cover from the inside;
  • pull the panel aside and remove it from the housing;
  • using a flat screwdriver, unscrew the screw of the sampler (this is necessary to check the gas pressure at the gas valve inlet). It is not necessary to unscrew the screw completely, a couple of turns is sufficient;
  • attach the spigot of the micromanometer;
  • open the gas supply tap;
  • the micromanometer display should show about 230 mm of water. test., which is within the normal range;
  • Close the gas supply tap;
  • remove the micromanometer socket;
  • screw the screw back in.

Since the gas pressure at the inlet is normal, Error 6A is still the issue that needs to be found.

Gas valve

The middle one is the gas valve. Although this boiler is not a Buderus boiler, it utilizes the exact same valve.

The resistance of the modulating and locking coils is implied by this check stage. Steps in an inspection:

  • disconnect the connectors from the coils (upper from the modulating coil and lower from the locking coils);
  • turn on the multimeter and set the resistance test mode with a limit of 200 ohms;
  • check the resistance of the modulating coil (a level of about 80 will be considered normal);
  • check the resistance of the upper closing coil, pins 1 and 2 and the lower one, pins 3 and 4.

The locking coil unit needs to be replaced if a circuit break is found on any of the coils.

Problem Description Error 6A on Buderus Logamax u072 gas boiler
Possible Cause Ignition failure or flame sensor issue
Steps to Check 1. Ensure gas supply is on and sufficient.
2. Check ignition electrode for dirt or damage.
3. Inspect flame sensor for carbon buildup.
4. Look for loose wiring connections.
Solution 1. Clean or replace ignition electrode if dirty or damaged.
2. Clean flame sensor to remove carbon deposits.
3. Tighten any loose wiring connections.
4. Reset the boiler after checking.

If your Buderus Logamax u072 gas boiler is displaying Error 6A, it’s

If you"re facing an Error 6A on your Buderus Logamax u072 gas boiler, it"s crucial to address it promptly to ensure your heating and insulation system works efficiently. This error typically points to issues with the burner or ignition, possibly caused by a lack of gas supply, faulty components, or blockages. Start by checking the gas supply to ensure it"s uninterrupted and that the gas valve is open. Inspect the ignition system and burner for any signs of wear or damage. Sometimes, a simple reset might solve the issue, but if the error persists, it"s best to consult a professional technician. Ignoring the error or attempting DIY fixes without proper knowledge can lead to bigger problems and compromise your home"s heating and insulation.

Video on the topic

Error 6A code indication Buderus Logamax U072 boiler 🛠 Cause and remedy 🔆 SIVTERMO

Buderus logomax u072 fixing unusual error 6a.

Boiler Buderus Logamax U072 – 24K error 6A