Ariston gas boiler. Error 501. Causes and how to eliminate

Having a dependable heating system is essential to keeping your house warm and inviting, especially in the winter. Ariston gas boilers are becoming more and more well-liked among the range of heating options available because of their effectiveness and efficiency. But just like any mechanical system, they could occasionally run into problems, like Error 501. In this post, we’ll examine the reasons behind Error 501 and look at workable fixes for it.

For homeowners, Error 501 on an Ariston gas boiler can be very frustrating, especially in cold weather. This error usually means that there is a problem with the flame detection or ignition system of the boiler. As a safety precaution to avert potential hazards, the boiler initiates Error 501 when it fails to ignite or detects a problem with the flame. The first step in fixing this error effectively is to identify its underlying causes.

Error 501 is frequently caused by a disruption in the boiler’s gas supply. There could be a number of causes for this, including a blocked gas line, low gas pressure, or a closed gas valve. The error can also result from problems with the flame sensor or ignition electrode, which prevents the boiler from lighting correctly. The boiler system must be carefully inspected and troubleshooted in order to identify these underlying problems.

There are various troubleshooting steps that can be performed in order to remove Error 501 and get your Ariston gas boiler operating properly again. First, make sure there are no obstructions in the gas line and that the valve is open by checking the gas supply. Next, look for any indications of buildup or damage, like rust or debris, on the flame sensor and ignition electrode. This problem might be fixed by cleaning or replacing these parts, enabling the boiler to ignite properly.

In the event that the steps listed above are ineffective in fixing Error 501, you might need to look for expert help. An expert technician with knowledge of maintaining Ariston gas boilers can carry out a comprehensive examination and precisely identify the underlying problem. Their proficiency and equipment enable them to recognize and tackle intricate issues, guaranteeing the secure and effective functioning of your heating system.

Error 501 An error code indicating a problem with the Ariston gas boiler.
Causes Possible reasons for Error 501 include issues with the ignition, gas supply, or internal components.
How to eliminate To fix Error 501, check the gas supply, ensure proper ignition, and inspect internal parts for any faults. If needed, contact a professional technician for assistance.

Error 501 on the gas boiler

Over time, even the most dependable machinery may malfunction or fail. There are many distinct reasons why equipment breaks down, including normal wear and tear, power surges, and user error. Don’t panic if the Ariston boiler stopped working and the error 501 light is on; there is a workaround for this scenario. Error 501 indicates that the gas burner on the Ariston gas boiler is not lighting up. Numerous factors can lead to this kind of issue:

  • no gas supply;
  • Faulty gas automatics;
  • electronics problems.

A diagnostic procedure must be performed in order to properly solve such an issue, and this will call for specific knowledge, abilities, tools, and measuring devices. It will be essential to get ready:

  • a set of screwdrivers with various attachments;
  • multimeter;
  • micromanometer.

Boiler diagnostics in case of error 501

It is not always possible to ignite a gas boiler in order to get it to function. Following multiple failed attempts, the screen displays error 501. It will be necessary to carry out specific procedures in order to perform diagnostics.

In this article, we delve into the common issue of Error 501 on Ariston gas boilers, focusing on its causes and solutions. Error 501 often indicates a problem with the ignition or flame detection system, leading to a disruption in heating operations. Causes can range from faulty ignition electrodes to issues with gas supply or blocked flues. Fortunately, resolving Error 501 can often be achieved through simple troubleshooting steps, such as checking for gas leaks, cleaning the ignition system, or resetting the boiler. By understanding the potential causes and implementing appropriate solutions, homeowners can effectively eliminate Error 501 and ensure their Ariston gas boiler operates smoothly, providing reliable heating for their homes.

Checking the gas supply

The Ariston boiler’s gas supply is checked right away. To do this in your home or apartment, approach the gas stove and determine whether the gas is ignited or not. It will be necessary to "restart" the boiler if there is a gas supply. Press the "Reset" button in the boiler’s control menu to accomplish this. If the issue persists after rebooting, proceed with the diagnostic process. When someone lacks confidence in their own skills, they should entrust the diagnosis and repair procedures to a qualified specialist who will complete the tasks accurately.

Checking the spark

On the control panel the boiler is switched off with the button and the gas supply to the boiler is cut off. Next, the boiler is disconnected from the power supply (usually pull the plug out of the socket, turn off the corresponding circuit breaker in the electrical panel). Then carefully remove the front decorative cover using a shaped screwdriver with a "star" tip. The screws to be removed are located at the bottom of the decorative panel. After unscrewing them, the panel comes off fairly quickly and easily by lifting it upwards. After that it is necessary to unfold the cover of the control panel (it is taken by the upper part, it is lowered in the downward direction). At the second stage of diagnostics the combustion chamber cover is removed to make sure that there is a spark. For such purposes, two special clips located at the bottom of the chamber are snapped off, then it can be easily removed. Then it will be necessary to unscrew 2 self-tapping screws, remove the firebox cover (it is lifted up and can be easily removed from the boiler). In a special furnace there are such elements as – heat exchanger, gas burner, special unit, which is responsible for the inclusion of 2 electrodes, 1 flame control electrode. It is necessary to thoroughly inspect all of them for defects and external mechanical damage. If there are any problems, then the spoiled units, elements of the boiler simply need to be replaced, using a special tool. After that it is necessary to turn on the boiler power supply, press the button on the control panel. Then after starting the pump, the fan is turned on – it is possible to observe whether there is a spark. In case of lack of spark, each of the electrodes is reassembled and checked to identify the breakage or defect.

Verify if this plug is providing the spark.

Checking the operating pressure

If there are no problems with the spark, and the error 501 at the gas boiler Ariston has not gone, then continue diagnostics. For this purpose it is necessary to disconnect the power supply, check the real working pressure of gas, and how the gas automatics is working. A micromanometer is used for such purposes. It will be necessary to turn it on, unscrew the screw of the sampler (using a flat screwdriver for 2 turns) to measure the gas entering the inlet. To do this, connect the micromanometer socket to the sampler and open the gas supply valve. If the pressure is about 259 mm of water column, it is good. In case of other values, the cause of low gas pressure is found out by contacting the appropriate organization. Then it is necessary to put everything back the way it was. Close the gas supply valve, remove the socket, tighten the sampler screw. If the previous check has not yielded results, then proceed to the next stage of diagnostics.

Brass makes up the three-way valve on the left. The gas valve, which has a blue head, is situated on the right. Ariston boiler will operate in a comparable manner.

Check gas automatics

At this stage, the state of the gas automatics, the resistance of the modulating and locking coils is checked. The procedure starts with a preliminary inspection of all elements for breakages, mechanical damage. After that the ignition transformer is dismantled from the gas valve (the fixing screw is removed with a Phillips screwdriver). Then the connectors are removed from the modulating coil. Next, the resistance is measured with a multimeter (in the 200 ohm resistance test mode). If the resistance of the modulating coil is about 78 ohms, it is normal. Next, the resistance of the locking coils is checked (measurement limit 20 kOhm). The probes are put on the upper locking coil on legs 1-3, and if the value obtained is about 6.5 k ohm, it is normal. Then the resistance of the second coil on legs 3-4 is measured (it should be about 1,6 kOhm).). It is important to know that if there is no numerical value of resistance (the value "1" is lit on the device), it means that some coil has failed – it is replaced. To change it, unscrew the special screw and pull it out. Then it is necessary to change to a new one that is in good working order. It is obligatory to measure the resistance after replacement.

Completion of the procedure of diagnostics and repair

Connecting the ignition transformer to the gas valve and the modulation coil’s connectors is required after replacing the faulty element. After that, the power supply is connected and the control panel is reinstalled. Subsequently, the gas supply to the boiler must be turned on. All of this is done to ensure that the gas boiler is operating properly. The issue is resolved if everything is in order.

When your Ariston gas boiler displays Error 501, it’s important to know what the possible causes could be and how to fix them. Your heating system may be disrupted and inconvenienced by this error, but it can be quickly fixed with the correct approach.

The boiler system’s low water pressure is one frequent cause of Error 501. Low pressure can cause the boiler to malfunction and display an error message. A straightforward first step in troubleshooting this issue is to check the pressure gauge on your boiler and make sure it is within the recommended range.

An additional potential reason for Error 501 could be an issue with the flame detection or ignition system. The boiler may display this error code if it is unable to ignite or detect a flame. In these situations, making sure there is an adequate fuel supply and looking for any obstructions or defects in the ignition components can help fix the problem.

Error 501 can also be caused by problems with the boiler’s exhaust system or ventilation. The combustion process may be hampered by obstructions or insufficient airflow, which could produce error messages. This issue can be avoided by checking the exhaust pipes, flues, and vents for damage or obstructions and making sure there is enough ventilation.

To ensure optimal performance and prevent errors such as Error 501, it is imperative to perform routine maintenance and servicing on your Ariston gas boiler. Annual inspections with a certified technician allow you to spot possible problems early on and take care of them before they become more serious. Not only does proper maintenance help prevent inconvenient breakdowns, but it also increases the boiler’s lifespan.

In conclusion, while Error 501 on your Ariston gas boiler can be annoying, it’s crucial to tackle the issue methodically. You can efficiently troubleshoot and fix this problem by inspecting ignition components, making sure there is enough ventilation, checking the water pressure, and making routine maintenance a priority. Proactively resolving Error 501 not only helps your heating system operate again, but it also increases the long-term dependability and efficiency of the system.

Video on the topic

Ariston Egis Plus error 5P3, 501. Flame bursting. No flame

Ariston Cares X 24FF boiler error 501

Error 501, repair of gas boiler Ariston Clas (evo), Egis, Genus (evo), Egis+.

Ariston Chaffoteaux Alixia S gas boiler does not start up. Error 501. No spark, no flame.

✅ No flame in the gas boiler ✅ Ariston error 501 how to fix it?

Error 501

What type of heating you would like to have in your home?
Share to friends
Sergey Ivanov

I like to help people create comfort and comfort in their homes. I share my experience and knowledge in articles so that you can make the right choice of a heating and insulation system for your home.

Rate author
vDomTeplo.com
Add a comment